Canon i-SENSYS LBP7110Cw
Рейтинг
Модули
100 EXTERNAL COVERS, PANELS, ETC.
102 INTERNAL COMPONENTS 2
101 INTERNAL COMPONENTS 1
103 INTERNAL COMPONENTS 3
104 INTERNAL COMPONENTS 4
PAPER FEED
Детали 100 EXTERNAL COVERS, PANELS, ETC.
Деталь: | COVER, FRONT, LOWER |
Парткод: | FE2-1412-000 |
Деталь: | COVER, TOP |
Парткод: | FE2-1416-000 |
Деталь: | COVER, LEFT |
Парткод: | FE2-1430-000 |
Деталь: | COVER UNIT, RIGHT |
Парткод: | FM0-2522-000 |
Деталь: | COVER UNIT, RIGHT |
Парткод: | FM0-2521-000 |
Деталь: | COVER, RIGHT |
Парткод: | FE2-1449-000 |
Деталь: | COVER, REAR, RIGHT |
Парткод: | FE2-1435-000 |
Деталь: | COVER, REAR, LOWER |
Парткод: | FE2-1436-000 |
Деталь: | LABEL, EXCHANGE PROCESS |
Парткод: | FE2-1451-000 |
Деталь: | SCREW, D, M3X8 |
Парткод: | XA9-1671-000 |
Цена: | 170 ₽ |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2505-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2506-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-4591-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2507-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2508-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2509-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2511-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2510-000 |
Деталь: | CONTROL PANEL ASSEMBLY |
Парткод: | FM0-2512-000 |
Деталь: | FRONT DOOR ASSY |
Парткод: | FM0-2513-000 |
Деталь: | SWITCH COVER ASSEMBLY |
Парткод: | FM0-2514-000 |
Деталь: | COVER, REAR MIDDLE |
Парткод: | FE2-1434-000 |
Деталь: | UPPER COVER ASSEMBLY, REAR |
Парткод: | FM0-2518-000 |
Деталь: | LABEL, GROUNDING CAUTION |
Парткод: | FU7-8875-000 |
Деталь: | LABEL, HIGH TMP. CAUTION |
Парткод: | FE2-1454-000 |
Деталь: | EXTERNAL COVERS, PANELS, ETC. |
Парткод: | NPN |
Деталь: | MAIN DRIVE ASSY |
Парткод: | RM1-9328-000 |
Деталь: | SUB DRIVE ASSY |
Парткод: | RM1-8785-000 |
Деталь: | DC CONTROLLER PCB ASSEMBLY |
Парткод: | FM0-3966-000 |
Деталь: | LOW VOLTAGE POWER SUPPLY ASSY |
Парткод: | RM1-9027-000 |
Деталь: | LOW VOLTAGE POWER SUPPLY ASSY |
Парткод: | RM1-9022-000 |
Деталь: | CABLE, FLEXIBLE FLAT |
Парткод: | RK2-4540-000 |
Деталь: | FAN |
Парткод: | RK2-4255-000 |
Деталь: | CABLE, FLEXIBLE FLAT |
Парткод: | RK2-3125-000 |
Деталь: | CABLE, FLEXIBLE FLAT |
Парткод: | FK3-3425-000 |
Деталь: | IC, PHOTO INTERRUPTER |
Парткод: | WG8-5935-000 |
Деталь: | DRIVER PCB ASSY |
Парткод: | RM1-8706-000 |
Деталь: | MAIN CONTROLLER PCB ASSEMBLY |
Парткод: | FM1-B950-000 |
Деталь: | MAIN CONTROLLER PCB ASSEMBLY |
Парткод: | FM1-B951-000 |
Деталь: | MAIN CONTROLLER PCB ASSEMBLY |
Парткод: | FM1-B952-000 |
Деталь: | SCREW, D, M3X8 |
Парткод: | XA9-1671-000 |
Цена: | 170 ₽ |
Деталь: | PLATE, LAN EXCHANGE |
Парткод: | FE2-1443-000 |
Деталь: | CABLE, FLEXIBLE FLAT |
Парткод: | FK3-3426-000 |
Деталь: | WIRELESS NETWORK PCB ASSEMBLY |
Парткод: | FM0-2519-000 |
Деталь: | SCREW, D, M3X6 |
Парткод: | XA9-1835-000 |
Деталь: | INTERNAL COMPONENTS 2 |
Парткод: | NPN |
Деталь: | SEPARATION ROLLER ASSY |
Парткод: | RM1-8765-000 |
Деталь: | PICK-UP ROLLER ASSY |
Парткод: | RM1-8047-030 |
Деталь: | FIXING POWER SUPPLY ASSY |
Парткод: | RM1-8720-000 |
Деталь: | FIXING POWER SUPPLY ASSY |
Парткод: | RM1-8721-000 |
Деталь: | COVER, HOLDER |
Парткод: | RC2-2014-000 |
Деталь: | CASSETTE ASSY |
Парткод: | FM0-2515-000 |
Деталь: | LASER SCANNER ASSEMBLY |
Парткод: | FM0-4590-000 |
Деталь: | LABEL, LASER CAUTION |
Парткод: | RU6-8007-000 |
Деталь: | SCREW, D, M3X8 |
Парткод: | XA9-1671-000 |
Цена: | 170 ₽ |
Деталь: | INTERNAL COMPONENTS 1 |
Парткод: | NPN |
Деталь: | I.T.B. LOCK LEVER ASSY, LEFT |
Парткод: | RM1-4482-000 |
Деталь: | I.T.B. LOCK LEVER ASSY, RIGHT |
Парткод: | RM1-4483-000 |
Деталь: | H.V. POWER SUPPLY PCB ASSY |
Парткод: | RM1-8705-010 |
Деталь: | INTERMEDIATE TRANS. BELT ASSY |
Парткод: | RM1-8777-000 |
Цена: | 20 500 ₽ |
Деталь: | PAPER FEED GUIDE ASSY |
Парткод: | RM1-8779-000 |
Деталь: | ROLLER, TRANSFER |
Парткод: | RM1-4445-000 |
Деталь: | SCREW, D, M3X8 |
Парткод: | XA9-1671-000 |
Цена: | 170 ₽ |
Деталь: | INTERNAL COMPONENTS 3 |
Парткод: | NPN |
Деталь: | FIXING ASSY (220-240V) |
Парткод: | FM0-2503-000 |
Деталь: | FIXING ASSY (220-240V) |
Парткод: | RM1-8780-000 |
Деталь: | FIXING ASSY (220-240V) |
Парткод: | RM1-8781-000 |
Цена: | 7 100 ₽ |
Деталь: | FIXING DRIVE ASSY |
Парткод: | RM1-8784-000 |
Цена: | 4 700 ₽ |
Деталь: | CARTRIDGE TRAY ASSY |
Парткод: | RM1-8774-000 |
Деталь: | MAIN SWITCH PCB ASSY |
Парткод: | FM0-2516-000 |
Деталь: | SCREW, D, M3X8 |
Парткод: | XA9-1671-000 |
Цена: | 170 ₽ |
Деталь: | LABEL, JAM CLEARING |
Парткод: | FE2-1452-000 |
Деталь: | LABEL, JAM CLEARING |
Парткод: | FE2-1453-000 |
Деталь: | INTERNAL COMPONENTS 4 |
Парткод: | NPN |
Деталь: | Pickup Roller |
Парткод: | RM1-8047-030CN |
Цена: | 450 ₽ |
Коды ошибок
E000-0000
E001-0000
E003-0000
E004-0000
E012-0000
E012-0001
E015-0001
E020-0000
E066-0000
E070-0000
E100-0000
E100-0001
E100-0002
E100-0003
E110-0000
E196-0000
E196-2000
E198-0000
E733-0000
E733-0001
E733-0004
E733-0005
E733-0006
E733-0007
E743-0000
E744-4000
E744-6000
E806-0000
E840-0000
Описание
Error code: | E000-0000 |
Description: | Startup error The temperature detected by the main or sub thermistor does not rise to the specified value during startup control. |
Causes: | The detection temperature of the main thermistor did not increase after start of the power distribution to the heater. |
Remedy: | - Check the fixing film connector. - Replace the fixing film unit. - Replace the DC controller PCB. |
Error code: | E001-0000 |
Description: | Abnormally high temperature (detected by main thermistor) The main thermistor detected an abnormally high temperature 235 deg C) during temperature control |
Causes: | The main thermistor detected a temperature of higher than 255 degree C. |
Remedy: | - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB. |
Error code: | E003-0000 |
Description: | Abnormally low temperature (detected by main thermistor) After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation. |
Causes: | The main thermistor detected a temperature of lower than 120 degree C for more than 1 second when 20 seconds elapsed after start of the power distribution to the heater. |
Remedy: | - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB. |
Error code: | E004-0000 |
Description: | Fixing power supply drive circuit error |
Causes: | 43 to 57Hz could not be detected continuously for more than 5 seconds when zero cross detection started. |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the DC Controller Board. (2) Replace the Fixing Assembly. |
Error code: | E012-0000 |
Description: | Error in ITB motor activation. |
Causes: | The cycle of ITB motor speed detection signal does not move in the specified cycle after ITB motor drive is started. Cause Failure in ITB motor, failure in DC controller PCB |
Remedy: | - Check the connectors of ITB motor and DC controller PCB - Replace the ITB motor - Replace the DC controller PCB |
Error code: | E012-0001 |
Description: | Error in ITB motor activation. |
Causes: | If the ITB motor speed detection signal comes off the specified cycle after it turned once to the specified cycle. Cause Failure in ITB motor, failure in DC controller PCB. |
Remedy: | - Check the connectors of ITB motor and DC controller PCB - Replace the ITB motor - Replace the DC controller PCB |
Error code: | E015-0001 |
Description: | Cassette 1 lift up motor error |
Causes: | Cassette 1 lift up motor error |
Remedy: | Reconnect the connector J151 on the DC controller PCB and the relay connector J742. Check the cassette media stack surface sensor in the sensor monitor mode. If a failure is found, replace the lifter drive unit. Replace the lifter drive unit. |
Error code: | E020-0000 |
Description: | Density sensor failure warning |
Error code: | E066-0000 |
Description: | Environment sensor failure |
Causes: | Environment sensor failure |
Remedy: | Replace the environment sensor. |
Error code: | E070-0000 |
Description: | Error in ITB / TOP sensor |
Causes: | Error in ITB / TOP sensor Cause: Problem in ITB / TOP sensor / DC controller PCB |
Remedy: | • Check connectors of ITB unit and DC controller PCB. • Replace ITB units • Replace DC controller PCBs |
Error code: | E100-0000 |
Description: | BD detection PCB failure The BD detection PCB is faulty. |
Causes: | Yellow optical assembly failure |
Remedy: | - Check the connector of the BD detection PCB. - Replace the laser scanner unit. - Replace the DC controller PCB. |
Error code: | E100-0001 |
Description: | Error detection on any of scanner motor, laser unit, and BD detection at scanner area. |
Causes: | Magenta optical assembly failure |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the Laser Scanner Unit. (2) Replace the DC Controller Board. |
Error code: | E100-0002 |
Description: | Optical assembly error (Laser) |
Causes: | Cyan optical assembly failure |
Remedy: | Check the contact of the connector between the laser scanner unit and the DC controller. Replace the laser scanner unit. |
Error code: | E100-0003 |
Description: | Optical assembly error (Laser) |
Causes: | Black optical assembly failure |
Remedy: | Check the contact of the connector between the laser scanner unit and the DC controller. Replace the laser scanner unit. |
Error code: | E110-0000 |
Description: | Optical assembly error (Scanner motor) |
Causes: | Optical assembly error (Scanner motor initial operation failure) |
Remedy: | Check the contact of the connector between the laser scanner unit and the DC controller. Replace the laser scanner unit. |
Error code: | E196-0000 |
Description: | Invalid RFU execution requested |
Causes: | D-con update for the host machine or the optional cassette is not completed. |
Error code: | E196-2000 |
Description: | ROM read/write error (Error in storing each setting values for user mode / service mode / factory mode) |
Causes: | Error in writing in/reading from ROM (storing settings) Cause: Problem in main controller PCB |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Update the set of the Controller Firmware (2) Replace the Main Controller Board. |
Error code: | E198-0000 |
Description: | DC controller memory failure |
Causes: | A checksum failure is found in the block where specific information of the DC controller PCB is saved. A communication error occurred when reading the specific information of the DC controller PCB from the NVRAM at power-on. |
Remedy: | If the failure cannot be removed by turning the power OFF/ON, replace the DC controller PCB. |
Error code: | E733-0000 |
Description: | Erroneous communication between controller and printer Cannot communicate with the printer at startup. |
Causes: | Printer communication error (communication error at initial communication and negotiation packet error) |
Remedy: | - Check the connectors of the DC controller PCB and image processor PCB for normal connection. - Check the power supply of the printer (Check whether initialization is performed at startup). - Replace the DC controller PCB or image processor PCB. |
Error code: | E733-0001 |
Description: | Printer communication error (Invalid communication after communication is established, Parity error) |
Remedy: | Turn on the power again. Replace the DC controller PCB. |
Error code: | E733-0004 |
Description: | Printer communication error (Undefined command error) |
Remedy: | Turn on the power again. Replace the DC controller PCB. |
Error code: | E733-0005 |
Description: | Printer communication error (Communication timeout error) |
Remedy: | Turn on the power again. Replace the DC controller PCB. |
Error code: | E733-0006 |
Description: | Printer communication error (Unknown communication error) |
Remedy: | Turn on the power again. Replace the DC controller PCB. |
Error code: | E733-0007 |
Description: | Printer communication error ?Communication error between the Engine Controller PCB and the Main Controller PCB occurred. |
Remedy: | 1. Turn OFF and then ON the main power. 2. Replace the Main Controller PCB. 3. Replace the Engine Controller PCB. |
Error code: | E743-0000 |
Description: | Error in main controller communication An error in reading of/writing to the Flash ROM in the Main Controller occurred. |
Causes: | Software sequence error |
Remedy: | 1. Turn OFF and then ON the main power. 2. Replace the Main Controller PCB. |
Error code: | E744-4000 |
Description: | Engine ID error (Invalid engine connection is detected) |
Causes: | Error in engine ID Detected illegal engine connection |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Check the DC Controller Board. (2) Update the Engine Firmware. (3) Update the set of the Controller Firmware |
Error code: | E744-6000 |
Description: | Communication error with Wireless LAN board. |
Causes: | Communication with the Wireless LAN PCB could not be established. |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the Wireless LAN Board. (4) Replace the Main Controller Board. |
Error code: | E806-0000 |
Description: | Fan Motor cannot rotate at specified revolution speed. |
Causes: | Fixing / fixing power supply cooling fan does not rotate in the specified rotation speed. Cause: Problem in fixing / fixing power supply cooling fan / DC controller PCB |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the Main Fan Unit. (2) Replace the DC Controller Board. |
Error code: | E840-0000 |
Description: | Pressure release mechanism failure |
Causes: | The target pressure position was not reached even when 3.5 seconds (approximately 1.5 rotation of the cam) elapsed after start of the fixing motor reverse rotation. |
Remedy: | Check the gears and detection flags related to fixing pressure release mechanism. Replace the fixing pressure release sensor (PS9). Replace the fixing motor. Replace the fixing assembly. |