Konica-Minolta bizhub 951 Pro
Рейтинг
Коды ошибок
C-0001
C-0002
C-0003
C-0004
C-0005
C-0006
C-0007
C-0008
C-0010
C-0011
C-0012
C-0020
C-0021
C-0022
C-0023
C-0024
C-0025
C-0101
C-0103
C-0104
C-0105
C-0106
C-0107
C-0108
C-0109
C-0110
C-0111
C-0112
C-0113
C-0114
C-0115
C-0116
C-0118
C-0119
C-0120
C-0121
C-0130
C-0131
C-0132
C-0133
C-0134
C-0140
C-0141
C-0142
C-0143
C-0144
C-0145
C-0150
C-0151
C-0152
C-0153
C-0201
C-0203
C-0204
C-0205
C-0207
C-0208
C-0222
C-0223
C-0226
C-0227
C-0230
C-0231
C-0240
C-0241
C-0242
C-0243
C-0244
C-0245
C-0250
C-0251
C-0252
C-0253
C-0254
C-0255
C-0261
C-0262
C-0263
C-0264
C-0265
C-0266
C-0271
C-0272
C-0273
C-0274
C-0275
C-0276
C-0281
C-0282
C-0283
C-0284
C-0285
C-0286
C-0304
C-0306
C-0307
C-0309
C-0310
C-0312
C-0320
C-0322
C-0323
C-0325
C-0326
C-0328
C-0329
C-0331
C-0341
C-0342
C-0344
C-0345
C-0347
C-0348
C-0350
C-0351
C-0353
C-0354
C-0356
C-0357
C-0359
C-0360
C-0361
C-0370
C-0371
C-0372
C-0373
C-0374
C-0375
C-0376
C-0377
C-0378
C-0379
C-0380
C-0381
C-0382
C-0383
C-0384
C-0385
C-0386
C-0387
C-0388
C-0389
C-0390
C-0391
C-0392
C-0393
C-0394
C-0395
C-0396
C-0397
C-0398
C-0399
C-0403
C-0404
C-0410
C-0411
C-0412
C-0413
C-0414
C-0420
C-0421
C-0422
C-0423
C-0424
C-0425
C-0501
C-0502
C-0503
C-0504
C-0505
C-0506
C-0507
C-0508
C-0509
C-0510
C-0511
C-0512
C-0513
C-0514
C-0515
C-0516
C-0517
C-0518
C-0519
C-0520
C-0521
C-0522
C-0523
C-0524
C-0525
C-0526
C-0527
C-0528
C-0529
C-0530
C-0531
C-0532
C-0533
C-0534
C-0535
C-0536
C-0537
C-0538
C-0539
C-0540
C-0541
C-0542
C-0543
C-0544
C-0545
C-0546
C-0547
C-0548
C-0561
C-0562
C-0563
C-0564
C-0565
C-0566
C-0567
C-0568
C-0569
C-0570
C-0571
C-0572
C-0573
C-0574
C-0575
C-0576
C-0577
C-0578
C-0579
C-0580
C-0581
C-0582
C-0583
C-0584
C-0601
C-0602
C-0603
C-0604
C-0605
C-0606
C-0611
C-0612
C-0613
C-0614
C-0615
C-0616
C-0621
C-0622
C-0623
C-0624
C-0625
C-0626
C-0631
C-0632
C-0633
C-0634
C-0635
C-0636
C-0637
C-0638
C-0639
C-0640
C-0641
C-0642
C-0651
C-0652
C-0653
C-0654
C-0655
C-0656
C-0657
C-0658
C-0659
C-0660
C-0661
C-0662
C-0671
C-0672
C-0673
C-0674
C-0675
C-0676
C-0677
C-0678
C-0679
C-0680
C-0681
C-0682
C-1001
C-1005
C-1006
C-1007
C-1009
C-1010
C-1011
C-1012
C-1013
C-1014
C-1017
C-1102
C-1103
C-1105
C-1106
C-1109
C-1113
C-1114
C-1115
C-1124
C-1125
C-1127
C-1130
C-1131
C-1132
C-1133
C-1134
C-1135
C-1136
C-1137
C-1141
C-1144
C-1147
C-1153
C-1154
C-1155
C-1156
C-1157
C-1158
C-1159
C-1170
C-1171
C-1172
C-1173
C-1174
C-1175
C-1176
C-1177
C-1179
C-1180
C-1181
C-1201
C-1202
C-1203
C-1204
C-1205
C-1206
C-1211
C-1212
C-1213
C-1214
C-1215
C-1216
C-1221
C-1222
C-1223
C-1224
C-1225
C-1226
C-1227
C-1228
C-1229
C-1230
C-1231
C-1232
C-1233
C-1234
C-1235
C-1241
C-1242
C-1243
C-1244
C-1245
C-1246
C-1247
C-1248
C-1249
C-1250
C-1251
C-1252
C-1253
C-1254
C-1255
C-1256
C-1257
C-1258
C-1259
C-1260
C-1261
C-1262
C-1263
C-1264
C-1265
C-1266
C-1267
C-1268
C-1269
C-1270
C-1271
C-1272
C-1273
C-1275
C-1281
C-1282
C-1290
C-1291
C-1292
C-1293
C-1294
C-1295
C-1299
C-1301
C-1302
C-1303
C-1304
C-1305
C-1306
C-1307
C-1308
C-1309
C-1310
C-1311
C-1316
C-1317
C-1318
C-1319
C-1320
C-1330
C-1331
C-1332
C-1333
C-1334
C-1341
C-1342
C-1351
C-1352
C-1353
C-1354
C-1355
C-1356
C-1357
C-1358
C-1359
C-1360
C-1361
C-1364
C-1402
C-1403
C-1404
C-1406
C-1407
C-1408
C-1411
C-1412
C-1432
C-1433
C-1435
C-1436
C-1437
C-1438
C-1439
C-1442
C-1451
C-1452
C-1454
C-1455
C-1456
C-1499
C-1501
C-1502
C-1504
C-1505
C-1506
C-1507
C-1508
C-1509
C-1510
C-1511
C-1512
C-1513
C-1514
C-1515
C-1516
C-1517
C-1518
C-1519
C-1520
C-1521
C-1522
C-1523
C-1524
C-1525
C-1526
C-1527
C-1528
C-1530
C-1531
C-1532
C-1534
C-1537
C-1538
C-1540
C-1541
C-1542
C-1543
C-1544
C-1545
C-1546
C-1547
C-1548
C-1549
C-1550
C-1551
C-1552
C-1553
C-1554
C-1555
C-1556
C-1557
C-1558
C-1559
C-1560
C-1561
C-1562
C-1565
C-1566
C-1567
C-1651
C-1652
C-1653
C-1654
C-1655
C-1656
C-2101
C-2102
C-2103
C-2201
C-2202
C-2203
C-2204
C-2205
C-2206
C-2207
C-2208
C-2209
C-2210
C-2211
C-2212
C-2213
C-2214
C-2215
C-2217
C-2220
C-2221
C-2222
C-2224
C-2225
C-2226
C-2227
C-2228
C-2230
C-2231
C-2233
C-2234
C-2235
C-2236
C-2237
C-2238
C-2241
C-2242
C-2304
C-2306
C-2307
C-2309
C-2311
C-2313
C-2317
C-2318
C-2401
C-2402
C-2403
C-2411
C-2412
C-2413
C-2701
C-2702
C-2704
C-2705
C-2801
C-2802
C-2803
C-2804
C-2807
C-2808
C-2809
C-2810
C-2811
C-2812
C-2815
C-2816
C-2821
C-2822
C-3102
C-3103
C-3104
C-3201
C-3202
C-3501
C-3502
C-3503
C-3504
C-3801
C-3802
C-3901
C-3902
C-3903
C-3904
C-3905
C-3906
C-4301
C-4303
C-4304
C-4305
C-4307
C-4314
C-4316
C-4701
C-4702
C-4703
C-4705
C-4706
C-4708
C-4709
C-4720
C-4721
C-4722
C-4725
C-4850
C-5010
C-5101
C-5102
C-5311
C-5313
C-5317
C-5319
C-5320
C-5322
C-5326
C-5327
C-5328
C-5329
C-5330
C-5332
C-5337
C-5338
C-5339
C-5340
C-5341
C-5343
C-5344
C-5345
C-5347
C-5348
C-6101
C-6102
C-6103
C-6301
C-6302
C-6303
C-6701
C-6702
C-6703
C-6704
C-6705
C-6706
C-6707
C-6708
C-6709
C-6710
C-6717
C-6719
C-6721
C-6801
C-8001
C-8002
C-8003
C-8201
C-8301
C-8401
C-8402
C-8403
C-8404
C-8405
C-8406
C-8407
C-8408
C-8409
C-8410
C-8411
C-8412
C-A001
C-A002
C-A003
C-A004
C-A005
C-A006
C-A007
C-A008
C-A009
C-A101
C-C101
C-C102
C-C103
C-C104
C-C105
C-C106
C-C107
C-C108
C-C109
C-C111
C-C112
C-C113
C-C114
C-C116
C-C117
C-C118
C-C119
C-C120
C-C121
C-C124
C-C125
C-C130
C-C131
C-C132
C-C136
C-D001
C-D002
C-D003
C-D004
C-D010
C-D080
C-E001
C-E002
C-E003
C-E004
C-E005
C-E006
C-E007
Описание
Error code: | C-0001 |
Description: | I/O initial communication check in the printer control board (PRCB). Main body drive serial input abnormality 1. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connection status of PRCB connector, and repair it if any abnormality. - 3 Replace PRCB. |
Error code: | C-0002 |
Description: | Main body drive serial input abnormality 2. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connection status of PRCB connector, and repair it if any abnormality. - 3 Replace PRCB. |
Error code: | C-0003 |
Description: | Main body drive serial input abnormality 3. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connection status of PRCB connector, and repair it if any abnormality. - 3 Replace PRCB. |
Error code: | C-0004 |
Description: | Main body drive serial input abnormality 4. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connection status of PRCB connector, and repair it if any abnormality. - 3 Replace PRCB. |
Error code: | C-0005 |
Description: | Main body drive serial input abnormality 5. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive board. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality. - 3 Check the connector connection on PRCB and ADUDB, and repair it if any abnormality. - 4 Replace ADUDB. - 5 Replace PRCB. - |
Error code: | C-0006 |
Description: | Drive communication reception error detection abnormality 4. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection status on PRCB, and repair it if any abnormality. - 3 Replace PRCB. |
Error code: | C-0007 |
Description: | Drive communication reception error detection abnormality 5. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection status on PRCB, and repair it if any abnormality. - 3 Replace PRCB. |
Error code: | C-0008 |
Description: | Drive communication reception error detection abnormality 6. |
Causes: | Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection status on PRCB, and repair it if any abnormality. - 3 Replace PRCB. |
Error code: | C-0010 |
Description: | Communication error check between the printer engine system boards. Drive communication reception error detection abnormality. A reception error interruption occurs while in the drive board serial data reception. Or, due to the occurrence of the data checksum error/ID information error, a retransmission request is made 3 times and an error is detected on the 4th time. |
Causes: | Confirmation of the wiring harness and the connector ADU drive board (ADUDB) LU drive board (LUDB) Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and PFUDB, and repair it if any abnormality. - 3 Check the connector connection on PRCB and PFUDB, and repair it if any abnormality. - 4 Replace PFUDB. - 5 Replace PRCB. |
Error code: | C-0011 |
Description: | Drive communication reception error detection abnormality 8. |
Causes: | Printer control board (PRCB: main body) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and PFUDB, and repair it if any abnormality. - 3 Check the connector connection on PRCB and PFUDB, and repair it if any abnormality. - 4 Replace PFUDB. - 5 Replace PRCB. |
Error code: | C-0012 |
Description: | Drive communication reception error detection abnormality 9. |
Causes: | Printer control board (PRCB: main body) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and PFUDB, and repair it if any abnormality. - 3 Check the connector connection on PRCB and PFUDB, and repair it if any abnormality. - 4 Replace PFUDB. - 5 Replace PRCB. |
Error code: | C-0020 |
Description: | Initial communication check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 1. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 0 of the ADUDB is not received. |
Causes: | Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality. 20-K 3 Check the connector connection on PRCB and ADUDB, and repair it if any abnormality. - 4 Replace ADUDB. - 5 Replace PRCB. |
Error code: | C-0021 |
Description: | Communication error check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 2. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 7 of the ADUDB is not received. |
Causes: | Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality. 20-K 3 Check the connector connection on PRCB and ADUDB, and repair it if any abnormality. - 4 Replace ADUDB. - 5 Replace PRCB. |
Error code: | C-0022 |
Description: | Initial communication check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 3. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 9 of the ADUDB is not received. |
Causes: | Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality. 20-K 3 Check the connector connection on PRCB and ADUDB, and repair it if any abnormality. - 4 Replace ADUDB. - 5 Replace PRCB. |
Error code: | C-0023 |
Description: | Drive communication reception error detection abnormality 0. |
Causes: | Printer control board (PRCB) ADU drive board (ADUDB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality. 20-K 3 Check the connector connection on PRCB and ADUDB, and repair it if any abnormality. - 4 Replace ADUDB. - 5 Replace PRCB. |
Error code: | C-0024 |
Description: | Drive communication reception error detection abnormality 7. |
Causes: | Printer control board (PRCB) ADU drive board (ADUDB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality. 20-K 3 Check the connector connection on PRCB and ADUDB, and repair it if any abnormality. - 4 Replace ADUDB. - 5 Replace PRCB. |
Error code: | C-0025 |
Description: | Drive communication reception error detection abnormality 11. |
Causes: | Printer control board (PRCB) ADU drive board (ADUDB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality. 20-K 3 Check the connector connection on PRCB and ADUDB, and repair it if any abnormality. - 4 Replace ADUDB. - 5 Replace PRCB. |
Error code: | C-0101 |
Description: | An abnormal speed signal of the paper feed motor (M4) is checked. An error detection signal is detected twice in succession a specified period of time after M4 was turned ON (the first signal is ignored). |
Causes: | Confirmation of the wiring harness and the connector Paper feed motor (M4) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 20-K 3 Replace M4. - 4 Replace PRCB. |
Error code: | C-0103 |
Description: | 1st tandem PF-702/703 paper feed motor (M1) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON. |
Causes: | Paper feed motor (M1: PF-702/703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 17-K 3 Replace M1. - 4 Replace PFUDB. |
Error code: | C-0104 |
Description: | The 24V power source for SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of ICP for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is also detected. |
Causes: | Confirmation of the wiring harness and the connector Wiring harness earth fault Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PRCB. 11-F 3 Replace M8 and PRCB at a time. |
Error code: | C-0105 |
Description: | The blowout of ICP for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of ICP for the solenoid/clutch) is detected. However, an error detection signal (24V cut off) is not detected. |
Causes: | Loose connection (on PRCB) Solenoid (SD5 to SD10, SD4, SD11) Clutch (CL3 to CL8, CL9, CL10) Wiring harness earth fault Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. 20-K 3 Replace M2 and PFUDB. |
Error code: | C-0106 |
Description: | 2nd tandem PF-702/703 paper feed motor (M1) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON. |
Causes: | Paper feed motor (M1: PF-702/703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 17-K 3 Replace M1. - 4 Replace PFUDB. |
Error code: | C-0107 |
Description: | Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the 2nd tandem PF-702. An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON. |
Causes: | PF exit conveyance motor (M2: PF-702) PF drive board (PFUDB: PF-702) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. 20-K 3 Replace M2 and PFUDB. |
Error code: | C-0108 |
Description: | Abnormality of the PF exit conveyance motor (M3) power in the PF drive board (PFUDB) of the 1st tandem PF-702. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON. |
Causes: | PF exit conveyance motor (M3: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 8-L 3 Replace M3 and PFUDB at a time. |
Error code: | C-0109 |
Description: | Abnormality of the PF exit conveyance motor (M3) power in the PF drive board (PFUDB) of the 2nd tandem PF-702. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON. |
Causes: | PF exit conveyance motor (M3: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 8-L 3 Replace M3 and PFUDB at a time. |
Error code: | C-0110 |
Description: | Abnormality of the registration section motor power in the ADU drive board (ADUDB). The error detection signals (blowout of ICP) of the ADU conveyance motor /2 (M16), the registration motor (M17) and the loop motor (M18) are detected after the print is started. |
Causes: | ADU conveyance motor /2 (M16) Registration motor (M17) Loop motor (M18) ADU drive board /2 (ADUDB2) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace ADUDB2. 23-L, 24-L 3 Replace ADUDB2. - 4 Replace M16, M17, M18 and ADUDB2 at a time. |
Error code: | C-0111 |
Description: | Abnormality of the duplex section motor power in the ADU drive board (ADUDB). The error detection signals (blowout of ICP) of the ADU reverse motor (M12), the reverse/exit motor (M13), the ADU accelerate motor (M14) and the ADU conveyance motor /1 (M15) are detected after the print is started. |
Causes: | ADU reverse motor (M12) Reverse/exit motor (M13) ADU accelerate motor (M14) ADU conveyance motor /1 (M15) ADU drive board /1 (ADUDB1) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace ADUDB1. 21-L, 22-L 3 Replace ADUDB1. - 4 Replace M12, M13, M14, M15 and ADUDB1 at a time. |
Error code: | C-0112 |
Description: | Vertical conveyance motor IC abnormality in the printer control board (PRCB) An error detection signal of vertical conveyance motor (M8) is detected after the print starts. |
Causes: | • Vertical conveyance motor (M8) • Printer control board (PRCB) |
Remedy: | 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace the M8 (Wiring diagram: Main body (3/4): 6-I). 3. Replace PRCB. 4. Replace M8 and PRCB at a time. |
Error code: | C-0113 |
Description: | Abnormality 1 of the SD/CL_24V power for the printer control board (PRCB) tray. At the start, the error detection signals of the PRCB tray solenoid/ clutch ICP blowout and 24V cut off are detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring related to DC24V between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-0114 |
Description: | Abnormality 2 of the SD/CL_24V power for the printer control board (PRCB) tray. When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start. |
Causes: | Paper feed clutch /1 (CL4) Separation clutch /1 (CL5) Paper feed clutch /2 (CL6) Separation clutch /2 (CL7) Pick-up solenoid /1 (SD3) Pick-up solenoid /2 (SD4) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring related to DC24V between PRCB and clutch/solenoid, and repair it if any abnormality. - 2 Check the drive and the coupling of the clutch and the solenoid, repair it if any abnormality, and then replace PRCB. 5-F, 8-F 3 Replace PRCB. - 4 Replace the clutch, the solenoid and PRCB at a time. |
Error code: | C-0115 |
Description: | Abnormality 1 of the SD/CL_24V power for the printer control board (PRCB) vertical conveyance. At the start, the error detection signals of the PRCB vertical conveyance solenoid/clutch ICP blowout and 24V cut off are detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring related to DC24V between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-0116 |
Description: | Abnormality 2 of the SD/CL_24V power for the printer control board (PRCB) tray. When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start. |
Causes: | Pre-registration clutch /1 (CL1) Vertical conveyance clutch (CL2) Pre-registration clutch /2 (CL3) Erase lamp (EL) Tray lock solenoid /1 (SD1) Tray lock solenoid /2 (SD2) Drum claw solenoid (SD10) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring related to DC24V between PRCB and clutch/solenoid/EL, and repair it if any abnormality. - 2 Check the drive and the coupling of the clutch, the solenoid and EL, repair/replace it if any abnormality, and then replace PRCB. 10-F, 5-M 3 Replace PRCB. - 4 Replace the clutch, the solenoid, EL and PRCB at a time. |
Error code: | C-0118 |
Description: | Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Check the drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/replace it if any abnormality, and then replace PFUDB. - 3 Replace PFUDB. - 4 If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time. |
Error code: | C-0119 |
Description: | The transfer belt cleaning motor (M5) speed abnormality. The M5EM error detection signal is detected twice in succession within a specified period of time after M5 was turned ON. |
Causes: | Transfer belt cleaning motor (M5) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 19-K 3 Replace M5. - 4 Replace PRCB. |
Error code: | C-0120 |
Description: | Paper exit conveyance motor (M31) speed abnormality. The M31EM error detection signal is detected twice in succession within a specified period of time after M31 was turned ON. |
Causes: | Paper exit conveyance motor (M31) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 22-K 3 Replace M31. - 4 Replace PRCB. |
Error code: | C-0121 |
Description: | Paper feed motor (M20) speed abnormality. The M20EM error detection signal is detected twice in succession within a specified period of time after M20 was turned ON. |
Causes: | Paper exit motor (M20) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 21-K 3 Replace M20. - 4 Replace PRCB. |
Error code: | C-0130 |
Description: | PF-703 coupling conveyance motor /1 (M4) power abnormality. An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON. |
Causes: | Coupling conveyance motor /1 (M4: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 20-L 3 Replace M4 and PFUDB at a time. |
Error code: | C-0131 |
Description: | PF-703 coupling conveyance motor /2 and /3 (M5 and M6) power abnormality. An error detection signal (blowout of ICP) of M5 and M6 is detected when M5 and M6 are turned ON. |
Causes: | Coupling conveyance motor /2 (M5: PF-703) Coupling conveyance motor /3 (M6: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 21-L 3 Replace PFUDB. - 4 Replace M5, M6 and PFUDB at a time. |
Error code: | C-0132 |
Description: | Abnormality of the power for the PF drive board (PFUDB) SD/CL of the 2nd tandem PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Check the drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/replace it if any abnormality, and then replace PFUDB. - 3 Replace PFUDB. - 4 If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time. |
Error code: | C-0133 |
Description: | 1st tandem PF-703 paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON. |
Causes: | Paper feed belt motor (M2: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 5-L 3 Replace M2. - 4 Replace PFUDB. |
Error code: | C-0134 |
Description: | 2nd tandem PF-703 paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON. |
Causes: | Paper feed belt motor (M2: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 5-L 3 Replace M2. - 4 Replace PFUDB. |
Error code: | C-0140 |
Description: | PI-PFU (PF-703) paper feed motor (M1) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON. |
Causes: | Paper feed motor (M1: PF-702/703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 17-K 3 Replace M1. - 4 Replace PFUDB. |
Error code: | C-0141 |
Description: | PI-PFU (PF-703) PF exit conveyance motor (M3) power abnormality. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON. |
Causes: | PF exit conveyance motor (M3: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 8-L 3 Replace M3 and PFUDB at a time. |
Error code: | C-0142 |
Description: | PI-PFU (PF-703) coupling conveyance motor /1 (M4) power abnormality. An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON. |
Causes: | Coupling conveyance motor /1 (M4: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 20-L 3 Replace M4 and PFUDB at a time. |
Error code: | C-0143 |
Description: | PI-PFU (PF-703) coupling conveyance motor /2 and /3 (M5 and M6) power abnormality. An error detection signal (blowout of ICP) of M5 and M6 is detected when M5 and M6 are turned ON. |
Causes: | Coupling conveyance motor /2 (M5: PF-703) Coupling conveyance motor /3 (M6: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 21-L 3 Replace PFUDB. - 4 Replace M5, M6 and PFUDB at a time. |
Error code: | C-0144 |
Description: | PI-PFU (PF-703) SD/CL power abnormality. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Check the drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/replace it if any abnormality, and then replace PFUDB. - 3 Replace PFUDB. - 4 If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time. |
Error code: | C-0145 |
Description: | PI-PFU (PF-703) paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON. |
Causes: | Paper feed belt motor (M2: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 5-L 3 Replace M2. - 4 Replace PFUDB. |
Error code: | C-0150 |
Description: | An abnormal speed signal of the paper feed motor (M101) is checked. An error detection signal is detected twice in succession a specified period of time after M101 was turned ON (the first signal is ignored). |
Causes: | • Paper feed motor (M101) • LU drive board (LUDB) |
Remedy: | 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LU: 6-C) 3. Replace M101. 4. Replace LUDB |
Error code: | C-0151 |
Description: | The locking of the paper lift motor (M100) is detected. When M100 is ON, an error detection signal of the M100 is detected in succession for 1 second. |
Causes: | • Paper lift motor (M100) • Lower limit sensor (PS101) • Upper limit sensor (PS109) • LU drive board (LUDB) DIPSW47-0 |
Remedy: | 1. Check the paper loaded condition and the rear end restriction plate misaligned of the tray, and repair it if any abnormality 2. Check the connector connection and the wiring between LUDB and motor/sensor, and repair it if any abnormality. 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LU: 4-G, 6-G) 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LU: 5-C) 5. Replace PS109 and PS101. 6. Replace M100. 7. Replace LUDB. |
Error code: | C-0152 |
Description: | Abnormality of the paper lift motor (M100) power in the LU drive board (LUDB). An error detection signal (blowout of ICP) of M100 is detected. |
Causes: | • Paper lift motor (M100) • LU drive board (LUDB) |
Remedy: | 1. Check the connector connection and the wiring between LUDB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace M100 (Wiring diagram: LU: 5-C) 3. Replace LUDB. 4. Replace M100 and LUDB at a time. |
Error code: | C-0153 |
Description: | Abnormality of the solenoid and clutch power in the LU drive board (LUDB). An error detection signals (blowout of ICP) of the pick up solenoid (SD100), the paper feed clutch (CL101), and the preregistration clutch (CL102) are detected after the print is started. |
Causes: | • Pick-up solenoid (SD100) • Paper feed clutch (CL101) • Pre-registration clutch (CL102) • LU drive board (LUDB) |
Remedy: | 1. Check the connector connection and the wiring between LUDB and solenoid/clutch, and repair it if any abnormality. 2. Check the I/O drive of the solenoid/clutch and the coupling of the gear, repair/replace it if any abnormality, and then replace SD100, CL101 and CL102 (Wiring diagram: LU: 7-G, 6-G) 3. Replace LUDB. 4. Replace SD100/CL101/CL102 and LUDB at a time |
Error code: | C-0201 |
Description: | Tray /1 up abnormality 1. When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20seconds after the tray lift-up motor /1 (M25) turns ON for lifting operation. At this time, an error detection signal (24V cut off) is detected. |
Causes: | Upper limit sensor /1 (PS6) Tray lift-up motor /1 (M25) Printer control board (PRCB) DC power supply /2 (DCPS /2) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate condition of the tray 1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 5-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. 3-G 5 Replace PS6. - 6 Replace M25. - 7 Replace PRCB. - 8 Replace DCPS /2. |
Error code: | C-0203 |
Description: | Tray /1 up abnormality 2. When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20seconds after the tray lift-up motor /1 (M25) turns ON for lifting operation. At this time, an error detection signal is not detected. |
Causes: | Upper limit sensor /1 (PS6) Tray lift-up motor /1 (M25) Printer control board (PRCB) DC power supply /2 (DCPS /2) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate condition of the tray 1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 5-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. 3-G 5 Replace PS6. - 6 Replace M25. - 7 Replace PRCB. - 8 Replace DCPS /2. |
Error code: | C-0204 |
Description: | The locking of the tray lift-up motor /1 (M25) is detected. An error detection signal of M25 is detected while M25 is ON. |
Causes: | Tray lift-up motor /1 (M25) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 5-F 3 Replace M25. - 4 Replace PRCB. |
Error code: | C-0205 |
Description: | Tray /2 up abnormality 1. When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20seconds after the tray lift-up motor /2 (M34) turns ON for lifting operation. At this time, an error detection signal (24V cut off) is detected. |
Causes: | Upper limit sensor /2 (PS10) Tray lift-up motor /2 (M34) Printer control board (PRCB) DC power supply /2 (DCPS /2) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate condition of the tray 2, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 8-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 6-G 5 Replace PS10. - 6 Replace M34. - 7 Replace PRCB. - 8 Replace DCPS /2. |
Error code: | C-0207 |
Description: | Tray /2 up abnormality 2. When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20seconds after the tray lift-up motor /2 (M34) turns ON for lifting operation. At this time, an error detection signal is not detected. |
Causes: | Upper limit sensor /2 (PS10) Tray lift-up motor /2 (M34) Printer control board (PRCB) DC power supply /2 (DCPS /2) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate condition of the tray 2, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 8-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 6-G 5 Replace PS10. - 6 Replace M34. - 7 Replace PRCB. - 8 Replace DCPS /2. |
Error code: | C-0208 |
Description: | The locking of the tray lift-up motor /2 (M34) is detected. When M34 is ON, an error detection signal of the M34 is detected. |
Causes: | Tray lift-up motor /2 (M34) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 8-F 3 Replace M34. - 4 Replace PRCB. |
Error code: | C-0222 |
Description: | 1st tandem PF-702/703 upper tray up abnormality. PF-702: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20seconds after the paper lift motor /1 (M42) turns ON for lifting operation. PF-703: When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and /Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting. |
Causes: | Upper limit sensor /1 (PS2: PF-702) Upper limit sensor /1 (PS5: PF-703) Paper lift motor /1 (M42: PF-702) Paper lift motor /1 (M7: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the upper tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 5-C PF-703: 6-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 3-C PF-703: 3-F 5 Replace PS2: PF-702 or PS5: PF-703. - 6 Replace M42: PF -702 or M7: PF-703. - 7 Replace PFUDB. |
Error code: | C-0223 |
Description: | The locking of the paper lift motor /1 of the 1st tandem PF-702/703 upper tray (M42: PF-702, M7: PF-703) is detected. When M42 and M7 are ON, error detection signals of the M42 and M7 are detected. |
Causes: | Paper lift motor /1 (M42: PF-702) Paper lift motor /1 (M7: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 5-C PF-703: 6-F 3 Replace M42: PF -702 or M7: PF-703. - 4 Replace PFUDB. |
Error code: | C-0226 |
Description: | 1st tandem PF-702/703 middle tray up abnormality. PF-702: When the upper limit sensor /2 (PS6) is OFF, PS6 does not turn ON within 20seconds after the paper lift motor /2 (M43) turns ON for lifting operation. PF-703: When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and /Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting. |
Causes: | Upper limit sensor /2 (PS6: PF-702) Upper limit sensor /2 (PS9: PF-703) Paper lift motor /2 (M43: PF-702) Paper lift motor /2 (M8: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the middle tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 12-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 5-C PF-703: 9-F 5 Replace PS6: PF-702 or PS9: PF-703. - 6 Replace M43: PF -702 or M8: PF-703. - 7 Replace PFUDB. |
Error code: | C-0227 |
Description: | The locking of the paper lift motor /2 of the 1st tandem PF-702/703 middle tray (M43: PF-702, M8: PF-703) is detected. When M43 and M8 are ON, error detection signals of the M43 and M8 are detected. |
Causes: | Paper lift motor /2 (M43: PF-702) Paper lift motor /2 (M8: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 12-F 3 Replace M43: PF -702 or M8: PF-703. - 4 Replace PFUDB. |
Error code: | C-0230 |
Description: | The locking of the paper lift motor /3 (M21) is detected. When M21 is ON, an error detection signal of the M21 is detected. |
Causes: | Tray 3 paper improperly loaded Tray 3 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /3 (M21) Upper limit sensor /1 (PS22) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the lower tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 7-C PF-703: 16-F 5 Replace PS10: PF-702 or PS13: PF-703. - 6 Replace M44: PF-702 or M9: PF703. - 7 Replace PFUDB. |
Error code: | C-0231 |
Description: | The locking of the paper lift motor /3 of the 1st tandem PF-702/703 lower tray (M44: PF-702, M9: PF-703) is detected. When M44 and M9 are ON, error detection signals of the M44 and M9 are detected. |
Causes: | Paper lift motor /3 (M44: PF-702) Paper lift motor /3 (M9: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace M44: PF -702 or M9: PF-703. - 4 Replace PFUDB. |
Error code: | C-0240 |
Description: | The locking of the paper lift motor (M100) is detected. When the paper lift motor (M100) is ON, an error detection signal of M100 is detected in succession for 1 second. |
Causes: | Confirmation of the wiring harness and the connector Paper lift motor (M100) Lower limit sensor (PS101) Upper limit sensor (PS109) LU drive board (LUDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the upper tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 5-C PF-703: 6-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 3-C PF-703: 3-F 5 Replace PS2: PF-702 or PS5: PF-703. - 6 Replace M42: PF -702 or M7: PF-703. - 7 Replace PFUDB. |
Error code: | C-0241 |
Description: | The locking of the paper lift motor /2 of the 2nd tandem PF-702/703 upper tray (M42: PF-702, M7: PF-703) is detected. When M42 and M7 are ON, error detection signals of the M42 and M7 are detected. |
Causes: | Paper lift motor /1 (M42: PF-702) Paper lift motor /1 (M7: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 5-C PF-703: 6-F 3 Replace M42: PF -702 or M7: PF-703. - 4 Replace PFUDB. |
Error code: | C-0242 |
Description: | 2nd tandem PF-702/703 middle tray up abnormality. PF-702: When the upper limit sensor /2 (PS6) is OFF, PS6 does not turn ON within 20seconds after the paper lift motor /2 (M43) turns ON for lifting operation. PF-703: When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and /Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting. |
Causes: | Upper limit sensor /2 (PS6: PF-702) Upper limit sensor /2 (PS9: PF-703) Paper lift motor /2 (M43: PF-702) Paper lift motor /2 (M8: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the middle tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 12-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 5-C PF-703: 9-F 5 Replace PS6: PF-702 or PS9: PF-703. - 6 Replace M43: PF -702 or M8: PF-703. - 7 Replace PFUDB. |
Error code: | C-0243 |
Description: | The locking of the paper lift motor /2 of the 2nd tandem PF-702/703 middle tray (M43: PF-702, M8: PF-703) is detected. When M43 and M8 are ON, error detection signals of the M43 and M8 are detected. |
Causes: | Paper lift motor /2 (M43: PF-702) Paper lift motor /2 (M8: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 12-F 3 Replace M43: PF -702 or M8: PF-703. - 4 Replace PFUDB. |
Error code: | C-0244 |
Description: | 2nd tandem PF-702/703 lower tray up abnormality. PF-702: When the upper limit sensor /3 (PS10) is OFF, PS10 does not turn ON within 20seconds after the paper lift motor /3 (M44) turns ON for lifting operation. PF-703: When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and /Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting. |
Causes: | Upper limit sensor /3 (PS10: PF-702) Upper limit sensor /3 (PS13: PF-703) Paper lift motor /3 (M44: PF-702) Paper lift motor /3 (M9: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the lower tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 7-C PF-703: 16-F 5 Replace PS10: PF-702 or PS13: PF-703. - 6 Replace M44: PF-702 or M9: PF703. - 7 Replace PFUDB. |
Error code: | C-0245 |
Description: | The locking of the paper lift motor /3 of the 2nd tandem PF-702/703 lower tray (M44: PF-702, M9: PF-703) is detected. When M44 and M9 are ON, error detection signals of the M44 and M9 are detected. |
Causes: | Paper lift motor /3 (M44: PF-702) Paper lift motor /3 (M9: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace M44: PF -702 or M9: PF-703. - 4 Replace PFUDB. |
Error code: | C-0250 |
Description: | PI-PFU (PF-703) upper tray up abnormality. When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and /Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting. |
Causes: | Upper limit sensor /1 (PS2: PF-702) Upper limit sensor /1 (PS5: PF-703) Paper lift motor /1 (M42: PF-702) Paper lift motor /1 (M7: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the upper tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 5-C PF-703: 6-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 3-C PF-703: 3-F 5 Replace PS2: PF-702 or PS5: PF-703. - 6 Replace M42: PF -702 or M7: PF-703. - 7 Replace PFUDB. |
Error code: | C-0251 |
Description: | The locking of the upper tray paper lift motor /1 (M7) is detected. When M7 is ON, an error detection signal of the M7 is detected. |
Causes: | Paper lift motor /1 (M42: PF-702) Paper lift motor /1 (M7: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 5-C PF-703: 6-F 3 Replace M42: PF -702 or M7: PF-703. - 4 Replace PFUDB. |
Error code: | C-0252 |
Description: | PI-PFU (PF-703) middle tray up abnormality. When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and /Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting. |
Causes: | Upper limit sensor /2 (PS6: PF-702) Upper limit sensor /2 (PS9: PF-703) Paper lift motor /2 (M43: PF-702) Paper lift motor /2 (M8: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the middle tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 12-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 5-C PF-703: 9-F 5 Replace PS6: PF-702 or PS9: PF-703. - 6 Replace M43: PF -702 or M8: PF-703. - 7 Replace PFUDB. |
Error code: | C-0253 |
Description: | The locking of the middle tray paper lift motor /2 (M8) is detected. When M8 is ON, an error detection signal of the M8 is detected. |
Causes: | Paper lift motor /2 (M43: PF-702) Paper lift motor /2 (M8: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 12-F 3 Replace M43: PF -702 or M8: PF-703. - 4 Replace PFUDB. |
Error code: | C-0254 |
Description: | PI-PFU (PF-703) lower tray up abnormality. When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and /Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting. |
Causes: | Upper limit sensor /3 (PS10: PF-702) Upper limit sensor /3 (PS13: PF-703) Paper lift motor /3 (M44: PF-702) Paper lift motor /3 (M9: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the paper loaded condition and the rear end restriction plate misaligned of the lower tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 7-C PF-703: 16-F 5 Replace PS10: PF-702 or PS13: PF-703. - 6 Replace M44: PF-702 or M9: PF703. - 7 Replace PFUDB. |
Error code: | C-0255 |
Description: | The locking of the lower tray paper lift motor /3 (M9) is detected. When M9 is ON, an error detection signal of the M9 is detected. |
Causes: | Paper lift motor /3 (M44: PF-702) Paper lift motor /3 (M9: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace M44: PF -702 or M9: PF-703. - 4 Replace PFUDB. |
Error code: | C-0261 |
Description: | 1st tandem PF-703 shutter motor /1 (M10) operation time abnormality 1. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /1 (M10: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10. - 4 Replace PFUDB. |
Error code: | C-0262 |
Description: | 1st tandem PF-703 shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /1 (M10: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10 and PFUDB at a time. |
Error code: | C-0263 |
Description: | 1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /2 (M11: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11. - 4 Replace PFUDB. |
Error code: | C-0264 |
Description: | 1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /2 (M11: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11 and PFUDB at a time. |
Error code: | C-0265 |
Description: | 1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 1. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /3 (M12: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12. - 4 Replace PFUDB. |
Error code: | C-0266 |
Description: | 1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /3 (M12: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12 and PFUDB at a time. |
Error code: | C-0271 |
Description: | 2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 1. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /1 (M10: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10. - 4 Replace PFUDB. |
Error code: | C-0272 |
Description: | 2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /1 (M10: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10 and PFUDB at a time. |
Error code: | C-0273 |
Description: | 2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /2 (M11: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11. - 4 Replace PFUDB. |
Error code: | C-0274 |
Description: | 2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /2 (M11: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11 and PFUDB at a time. |
Error code: | C-0275 |
Description: | 2nd tandem PF-703 shutter motor /3 (M12) operation time abnormality 1. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /3 (M12: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12. - 4 Replace PFUDB. |
Error code: | C-0276 |
Description: | 2nd tandem PF-703 shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /3 (M12: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12 and PFUDB at a time. |
Error code: | C-0281 |
Description: | PI-PFU (PF-703)shutter motor /1 (M10) operation time abnormality 1. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /1 (M10: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10. - 4 Replace PFUDB. |
Error code: | C-0282 |
Description: | PI-PFU (PF-703)shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is detected. |
Causes: | Shutter motor /1 (M10: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10 and PFUDB at a time. |
Error code: | C-0283 |
Description: | PI-PFU (PF-703)shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /2 (M11: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11. - 4 Replace PFUDB. |
Error code: | C-0284 |
Description: | PI-PFU (PF-703)shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /2 (M11: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11 and PFUDB at a time. |
Error code: | C-0285 |
Description: | PI-PFU (PF-703)shutter motor /3 (M12) operation time abnormality 1. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
Causes: | Shutter motor /3 (M12: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12. - 4 Replace PFUDB. |
Error code: | C-0286 |
Description: | PI-PFU (PF-703)shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Shutter motor /3 (M12: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12 and PFUDB at a time. |
Error code: | C-0304 |
Description: | Rotation of paper exit cooling fan /Lw1 (FM13), /Lw2 (FM14) is checked. An abnormal condition occurs with the FM13, FM14 EM signal a specified period of time after FM 13, FM14 is turned ON. This abnormal condition is detected even a specified period of time after FM13, FM14 is turned OFF and then turned ON. |
Causes: | Confirmation of the wiring harness and the connector Paper exit cooling fan /Lw1 (FM13) Paper exit cooling fan /Lw2 (FM14) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-0306 |
Description: | The blowout of ICP for the paper exit cooling fans /Lw1 (FM13), / Lw2 (FM14), /Up1 (FM15) and / Up2 (FM17) is detected. An abnormal condition occurs either with the FM13 EM signal and the FM14 EM signal a specified period of time after FM13 and FM14 are turned ON or with the FM15 EM signal and the FM17 EM signal a specified period of time after FM15 and FM17 are turned ON. With this abnormal condition, an error detection signal (blowout of ICP) is detected and the door close is detected 5 times in succession. |
Causes: | Confirmation of the wiring harness and the connector Paper exit cooling fan /Lw1 (FM13) Paper exit cooling fan /Lw2 (FM14) Paper exit cooling fan /Up1 (FM15) Paper exit cooling fan /Up2 (FM17) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 4 Replace FM4 - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-0307 |
Description: | The rotation of the developing cooling fan (FM19) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 is turned ON. This abnormal condition recurs even a specified period of time after FM is turned OFF and then ON again, and an error detection signal (24V cut off) is detected. |
Causes: | Confirmation of the wiring harness and the connector DC power supply /2 (DCPS2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-0309 |
Description: | The rotation of the developing cooling fan (FM19) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 is turned ON. This abnormal condition recurs even a specified period of time after FM19 is turned OFF and then ON again, and an error detection signal (24V cut off/blowout of ICP) is not detected. |
Causes: | Confirmation of the wiring harness and the connector DC power supply /2 (DCPS2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 4 Replace FM10. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-0310 |
Description: | Rotation of paper exit cooling fan /Lw1 (FM13), /Lw2 (FM14) is checked. An abnormal condition occurs with the FM13, FM14 EM signal a specified period of time after FM13, FM 14 is turned ON. This abnormal condition is detected even a specified period of time after FM13, FM14 is turned OFF and then ON again. |
Causes: | Confirmation of the wiring harness and the connector Paper exit cooling fan /Lw1 (FM13) Paper exit cooling fan /Lw2 (FM14) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-0312 |
Description: | Paper exit cooling fan /Lw2 (FM28) rotation abnormality. The FM28EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. However, error detection signals (24V cut off/ICP blowout) are not detected. |
Causes: | Paper exit cooling fan /Lw2 (FM28) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fun or I/O by hand, and repair it if any abnormality. 4-L 4 Replace FM28. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-0320 |
Description: | Paper feed assist fan /Fr1 (FM21) rotation abnormality + 24V power abnormality. The FM21EM error detection signal is detected twice in succession within a specified period of time after FM21 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-0322 |
Description: | Paper feed assist fan /Fr1 (FM21) rotation abnormality. The FM21EM error detection signal is detected twice in succession within a specified period of time after FM21 was turned ON. However, error detection signals (24V cut off/ICP blowout) are not detected. |
Causes: | Paper feed assist fan /Fr1 (FM21) Paper feed assist fan /Rr1 (FM20) Paper feed assist fan /Fr2 (FM23) Paper feed assist fan /Rr2 (FM24) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-F, 8-F 3 C-0322: Replace FM21. C-0325: Replace FM20. C-0328: Replace FM23. C-0331: Replace FM24. - 4 Replace PRCB. |
Error code: | C-0323 |
Description: | Paper feed assist fan /Fr1 (FM20) rotation abnormality + 24V power abnormality. The FM20EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Error code: | C-0325 |
Description: | Paper feed assist fan /Rr1 (FM20) rotation abnormality. The FM20EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. However, error detection signals (24V cut off/ICP blowout) are not detected. |
Causes: | Paper feed assist fan /Fr1 (FM21) Paper feed assist fan /Rr1 (FM20) Paper feed assist fan /Fr2 (FM23) Paper feed assist fan /Rr2 (FM24) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-F, 8-F 3 C-0322: Replace FM21. C-0325: Replace FM20. C-0328: Replace FM23. C-0331: Replace FM24. - 4 Replace PRCB. |
Error code: | C-0326 |
Description: | Paper feed assist fan /Fr2 (FM23) rotation abnormality + 24V power abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-0328 |
Description: | Paper feed assist fan /Fr2 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, error detection signals (24V cut off/ICP blowout) are not detected. |
Causes: | Paper feed assist fan /Fr1 (FM21) Paper feed assist fan /Rr1 (FM20) Paper feed assist fan /Fr2 (FM23) Paper feed assist fan /Rr2 (FM24) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-F, 8-F 3 C-0322: Replace FM21. C-0325: Replace FM20. C-0328: Replace FM23. C-0331: Replace FM24. - 4 Replace PRCB. |
Error code: | C-0329 |
Description: | Paper feed assist fan /Rr2 (FM24) rotation abnormality + 24V power abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-0331 |
Description: | Paper feed assist fan /Rr2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, error detection signals (24V cut off/ICP blowout) are not detected. |
Causes: | Paper feed assist fan /Fr1 (FM21) Paper feed assist fan /Rr1 (FM20) Paper feed assist fan /Fr2 (FM23) Paper feed assist fan /Rr2 (FM24) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-F, 8-F 3 C-0322: Replace FM21. C-0325: Replace FM20. C-0328: Replace FM23. C-0331: Replace FM24. - 4 Replace PRCB. |
Error code: | C-0341 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1 and PFUDB. |
Error code: | C-0342 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and FM1, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1. - 4 Replace PFUDB. |
Error code: | C-0344 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Rr1 (FM2) power abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr1 (FM2: PF-703) Printer control board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM2 and PFUDB. |
Error code: | C-0345 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr1 (FM2: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM2. - 4 Replace PFUDB. |
Error code: | C-0347 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Fr2 (FM3: PF-702, FM5: PF-703) power abnormality. The FM3EM and FM5EM error detection signals are detected twice in succession within a specified period of time after FM3 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr2 (FM3: PF-702) Paper feed assist fan /Fr2 (FM5: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 10-F 3 Replace FM3 and PFUDB at a time: PF-702 Replace FM5 and PFUDB at a time: PF-703 |
Error code: | C-0348 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Fr2 (FM3: PF-702, FM5: PF-703) rotation abnormality. The FM3EM and FM5EM error detection signals are detected twice in succession within a specified period of time after FM3 and FM5 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr2 (FM3: PF-702) Paper feed assist fan /Fr2 (FM5: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 10-F 3 Replace FM3: PF-702 Replace FM5: PF-703 - 4 Replace PFUDB. |
Error code: | C-0350 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Fr2 (FM4: PF-702, FM6: PF-703) power abnormality. The FM4EM and FM6EM error detection signals are detected twice in succession within a specified period of time after FM4 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr2 (FM4: PF-702) Paper feed assist fan /Rr2 (FM6: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 11-F 3 Replace FM4 and PFUDB at a time: PF-702 Replace FM6 and PFUDB at a time: PF-703 |
Error code: | C-0351 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Rr2 (FM4: PF-702, FM6: PF-703) rotation abnormality. The FM4EM and FM6EM error detection signals are detected twice in succession within a specified period of time after FM4 and FM6 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr2 (FM4: PF-702) Paper feed assist fan /Rr2 (FM6: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 11-F 3 Replace FM4: PF-702 Replace FM6: PF-703 - 4 Replace PFUDB. |
Error code: | C-0353 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) power abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5 and PFUDB at a time: PF-702 Replace FM9 and PFUDB at a time: PF-703 |
Error code: | C-0354 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) rotation abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5: PF-702 Replace FM9: PF-703 - 4 Replace PFUDB. |
Error code: | C-0356 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) power abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6 and PFUDB at a time: PF-702 Replace FM10 and PFUDB at a time: PF-703 |
Error code: | C-0357 |
Description: | 1st tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) rotation abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6: PF-702 Replace FM10: PF-703 - 4 Replace PFUDB. |
Error code: | C-0359 |
Description: | 1st tandem PF-702/703 cooling fan power abnormality. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7 and PFUDB at a time: PF-702 Replace FM19, FM20 and PFUDB at a time: PF-703 |
Error code: | C-0360 |
Description: | 1st tandem PF-702/703 cooling fan rotation abnormality 1. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. However, an error detection signal (blowout of ICP) is not detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7: PF-702 Replace FM19 and FM20: PF-703 - 4 Replace PFUDB. |
Error code: | C-0361 |
Description: | 1st tandem PF-703 cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | PF cooling fan /3 (FM21: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 23-F 3 Replace FM21 and PFUDB at a time. |
Error code: | C-0370 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1 and PFUDB. |
Error code: | C-0371 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and FM1, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1. - 4 Replace PFUDB. |
Error code: | C-0372 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Rr1 (FM2) power abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr1 (FM2: PF-703) Printer control board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM2 and PFUDB. |
Error code: | C-0373 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr1 (FM2: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM2. - 4 Replace PFUDB. |
Error code: | C-0374 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Fr2 (FM3: PF-702, FM5: PF-703) power abnormality. The FM3EM and FM5EM error detection signals are detected twice in succession within a specified period of time after FM3 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr2 (FM3: PF-702) Paper feed assist fan /Fr2 (FM5: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 10-F 3 Replace FM3 and PFUDB at a time: PF-702 Replace FM5 and PFUDB at a time: PF-703 |
Error code: | C-0375 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Fr2 (FM3: PF-702, FM5: PF-703) rotation abnormality. The FM3EM and FM5EM error detection signals are detected twice in succession within a specified period of time after FM3 and FM5 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr2 (FM3: PF-702) Paper feed assist fan /Fr2 (FM5: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 10-F 3 Replace FM3: PF-702 Replace FM5: PF-703 - 4 Replace PFUDB. |
Error code: | C-0376 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Rr2 (FM4: PF-702, FM6: PF-703) power abnormality. The FM4EM and FM6EM error detection signals are detected twice in succession within a specified period of time after FM4 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr2 (FM4: PF-702) Paper feed assist fan /Rr2 (FM6: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 11-F 3 Replace FM4 and PFUDB at a time: PF-702 Replace FM6 and PFUDB at a time: PF-703 |
Error code: | C-0377 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Rr2 (FM4: PF-702, FM6: PF-703) rotation abnormality. The FM4EM and FM6EM error detection signals are detected twice in succession within a specified period of time after FM4 and FM6 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr2 (FM4: PF-702) Paper feed assist fan /Rr2 (FM6: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 11-F 3 Replace FM4: PF-702 Replace FM6: PF-703 - 4 Replace PFUDB. |
Error code: | C-0378 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) power abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5 and PFUDB at a time: PF-702 Replace FM9 and PFUDB at a time: PF-703 |
Error code: | C-0379 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) rotation abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5: PF-702 Replace FM9: PF-703 - 4 Replace PFUDB. |
Error code: | C-0380 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) power abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6 and PFUDB at a time: PF-702 Replace FM10 and PFUDB at a time: PF-703 |
Error code: | C-0381 |
Description: | 2nd tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) rotation abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6: PF-702 Replace FM10: PF-703 - 4 Replace PFUDB. |
Error code: | C-0382 |
Description: | 2nd tandem PF-702/703 cooling fan power abnormality. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7 and PFUDB at a time: PF-702 Replace FM19, FM20 and PFUDB at a time: PF-703 |
Error code: | C-0383 |
Description: | 2nd tandem PF-702/703 cooling fan rotation abnormality 1. PF-702: The FM20EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. However, an error detection signal (blowout of ICP) is not detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7: PF-702 Replace FM19 and FM20: PF-703 - 4 Replace PFUDB. |
Error code: | C-0384 |
Description: | 2nd tandem PF-703 cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | PF cooling fan /3 (FM21: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 23-F 3 Replace FM21 and PFUDB at a time. |
Error code: | C-0385 |
Description: | PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1 and PFUDB. |
Error code: | C-0386 |
Description: | PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and FM1, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1. - 4 Replace PFUDB. |
Error code: | C-0387 |
Description: | PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) power abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr1 (FM2: PF-703) Printer control board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM2 and PFUDB. |
Error code: | C-0388 |
Description: | PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr1 (FM2: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM2. - 4 Replace PFUDB. |
Error code: | C-0389 |
Description: | PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) power abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr2 (FM3: PF-702) Paper feed assist fan /Fr2 (FM5: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 10-F 3 Replace FM3 and PFUDB at a time: PF-702 Replace FM5 and PFUDB at a time: PF-703 |
Error code: | C-0390 |
Description: | PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) rotation abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr2 (FM3: PF-702) Paper feed assist fan /Fr2 (FM5: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 10-F 3 Replace FM3: PF-702 Replace FM5: PF-703 - 4 Replace PFUDB. |
Error code: | C-0391 |
Description: | PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr2 (FM4: PF-702) Paper feed assist fan /Rr2 (FM6: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 11-F 3 Replace FM4 and PFUDB at a time: PF-702 Replace FM6 and PFUDB at a time: PF-703 |
Error code: | C-0392 |
Description: | PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) rotation abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr2 (FM4: PF-702) Paper feed assist fan /Rr2 (FM6: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 11-F 3 Replace FM4: PF-702 Replace FM6: PF-703 - 4 Replace PFUDB. |
Error code: | C-0393 |
Description: | PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) power abnormality. The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5 and PFUDB at a time: PF-702 Replace FM9 and PFUDB at a time: PF-703 |
Error code: | C-0394 |
Description: | PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) rotation abnormality. The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5: PF-702 Replace FM9: PF-703 - 4 Replace PFUDB. |
Error code: | C-0395 |
Description: | PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) power abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6 and PFUDB at a time: PF-702 Replace FM10 and PFUDB at a time: PF-703 |
Error code: | C-0396 |
Description: | PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) rotation abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6: PF-702 Replace FM10: PF-703 - 4 Replace PFUDB. |
Error code: | C-0397 |
Description: | PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7 and PFUDB at a time: PF-702 Replace FM19, FM20 and PFUDB at a time: PF-703 |
Error code: | C-0398 |
Description: | PI-PFU (PF-703) cooling fan rotation abnormality 1. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7: PF-702 Replace FM19 and FM20: PF-703 - 4 Replace PFUDB. |
Error code: | C-0399 |
Description: | PI-PFU (PF-703) cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | PF cooling fan /3 (FM21: PF-703) PF drive board (PFUDB) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 23-F 3 Replace FM21 and PFUDB at a time. |
Error code: | C-0403 |
Description: | The 12V power source in the printer control board (PRCB) is checked. An error detection signal of the 12V in PRCB is detected. |
Causes: | Confirmation of the wiring harness and the connector Printer control board (PRCB) DC power supply /1 (DCPS1) |
Remedy: | 1 Check the connector connection and the wiring on PRCB, and repair it if any abnormality. - 2 Replace PRCB. - 3 Replace DCPS /2. |
Error code: | C-0404 |
Description: | 5V power abnormality in the printer control board (PRCB). An error detection signal of the 5V in PRCB (blowout of ICP) is detected. |
Causes: | Printer control board (PRCB) DC power supply /2 (DCPS /2) |
Remedy: | 1 Check the connector connection and the wiring on PRCB, and repair it if any abnormality. - 2 Replace PRCB. - 3 Replace DCPS /2. |
Error code: | C-0410 |
Description: | 12V ICP blowout in the ADU drive board (ADUDB). A -5V ICP blowout signal and blowout of a 12V ICP signal are detected for the serial initial communication. |
Causes: | Confirmation of the wiring harness and the connector ADU drive board (ADUDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. - 2 Replace ADUDB1. - 3 Replace DCPS /2. |
Error code: | C-0411 |
Description: | 24V power source of the ADU drive board is checked. At the start, an error detection signal (blowout of ICP for the transfer exposure lamp/solenoid) is detected, and an error detection signal (24V cut off) is detected. |
Causes: | Confirmation of the wiring harness and the connector Centering sensor (PS1) Transfer exposure lamp (EL2) ADU lock solenoid (SD1) Reverse/exit solenoid (SD2) Fusing solenoid (SD3) ADU drive board (ADUDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB1 and DCPS /1, and repair it if any abnormality. - 3 Replace ADUDB1. - 4 Replace DCPS /1. |
Error code: | C-0412 |
Description: | At the start, an error detection signal (blowout of the ICP for the transfer exposure lamp/solenoid) is detected. However, an error detection signal (24V cut off) is not detected. |
Causes: | Confirmation of the wiring harness and the connector Centering sensor (PS1) Transfer exposure lamp (EL2) ADU lock solenoid (SD1) Reverse/exit solenoid (SD2) Fusing solenoid (SD3) ADU drive board (ADUDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB1 and sensor/solenoid, and repair it if any abnormality. 17-L, 18-O 3 Check the drive and the coupling of the sensor and the solenoid, and repair it if any abnormality. - 2 Replace ADUDB1. |
Error code: | C-0413 |
Description: | Interlock power abnormality of the ADU drive board (ADUDB). An error signal of the 24V interlock power is detected in the door detection closed status. |
Causes: | ADU drive board /1 (ADUDB1) DC power supply /3 (DCPS /3) |
Remedy: | 1 Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB1 and DCPS /3, and repair it if any abnormality. - 3 Replace ADUDB1. - 4 Replace DCPS /3. |
Error code: | C-0414 |
Description: | During the centering censor (PS4) is ON, the centering data does not sent from the ADU drive board though more than 5 sheets are processed in succession. |
Causes: | • Centering sensor(PS4) • ADU drive board /1 (ADUDB1) |
Remedy: | 1. Check the connector connection and the wiring between ADUDB1 and the sensor, and repair it if any abnormality. 2. Check I/O of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (2/4): 14-J) 3. Replace PS4. 4. Replace ADUDB1. |
Error code: | C-0420 |
Description: | Abnormality of the 24V power for the PF drive board (PFUDB) of the 1st tandem PF-702/703. An error detection signal of the PFUDB (blowout of 12V ICP) is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB. |
Error code: | C-0421 |
Description: | Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-702/703. An error detection signal of the PFUDB (blowout of 12V ICP) is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB. |
Error code: | C-0422 |
Description: | Abnormality of the 24V power for the PF drive board (PFUDB) of the 1st tandem PF-702/703. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB. |
Error code: | C-0423 |
Description: | Abnormality of the 24V power for the PF drive board (PFUDB) of the 2nd tandem PF-702/703. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB. |
Error code: | C-0424 |
Description: | Abnormality of the 12V power for the PF drive board (PFUDB) of PIPFU (PF-703). An error detection signal of the PFUDB (blowout of 12V ICP) is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB. |
Error code: | C-0425 |
Description: | Abnormality of the 24V power for the PF drive board (PFUDB) of PIPFU (PF-703). While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected. |
Causes: | PF drive board (PFUDB: PF-702/703) |
Remedy: | 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB. |
Error code: | C-0501 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 and PFUDB at a time. |
Error code: | C-0502 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 - 4 Replace PFUDB. |
Error code: | C-0503 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7 and PFUDB at a time. |
Error code: | C-0504 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7. - 4 Replace PFUDB. |
Error code: | C-0505 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11 and PFUDB at a time. |
Error code: | C-0506 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11. - 4 Replace PFUDB. |
Error code: | C-0507 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr1 (FM4: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM4 and PFUDB at a time. |
Error code: | C-0508 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr1 (FM4: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM4 - 4 Replace PFUDB. |
Error code: | C-0509 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr2 (FM8: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM8 and PFUDB at a time. |
Error code: | C-0510 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr2 (FM8: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM8. - 4 Replace PFUDB. |
Error code: | C-0511 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr3 (FM12: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM12 and PFUDB at a time. |
Error code: | C-0512 |
Description: | 1st tandem PF-703 paper leading edge separation fan /Rr3 (FM12) rotation abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr3 (FM12: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM12. - 4 Replace PFUDB. |
Error code: | C-0513 |
Description: | 1st tandem PF-703 paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /1 (FM13: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM13 and PFUDB at a time. |
Error code: | C-0514 |
Description: | 1st tandem PF-703 paper suction fan /1 (FM13) rotation abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /1 (FM13: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM13. - 4 Replace PFUDB. |
Error code: | C-0515 |
Description: | 1st tandem PF-703 paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /3 (FM15: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM15 and PFUDB at a time. |
Error code: | C-0516 |
Description: | 1st tandem PF-703 paper suction fan /3 (FM15) rotation abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /3 (FM15: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM15. - 4 Replace PFUDB. |
Error code: | C-0517 |
Description: | 1st tandem PF-703 paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /5 (FM17: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM17 and PFUDB at a time. |
Error code: | C-0518 |
Description: | 1st tandem PF-703 paper suction fan /5 (FM17) rotation abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /5 (FM17: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM17. - 4 Replace PFUDB. |
Error code: | C-0519 |
Description: | 1st tandem PF-703 paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /2 (FM14: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM14 and PFUDB at a time. |
Error code: | C-0520 |
Description: | 1st tandem PF-703 paper suction fan /1 (FM14) rotation abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /2 (FM14: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM14. - 4 Replace PFUDB. |
Error code: | C-0521 |
Description: | 1st tandem PF-703 paper suction fan /3 (FM16) power abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /4 (FM16: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM16 and PFUDB at a time. |
Error code: | C-0522 |
Description: | 1st tandem PF-703 paper suction fan /3 (FM16) rotation abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /4 (FM16: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM16. - 4 Replace PFUDB. |
Error code: | C-0523 |
Description: | 1st tandem PF-703 paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /6 (FM18: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM18 and PFUDB at a time. |
Error code: | C-0524 |
Description: | 1st tandem PF-703 paper suction fan /5 (FM18) rotation abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /6 (FM18: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM18. - 4 Replace PFUDB. |
Error code: | C-0525 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 and PFUDB at a time. |
Error code: | C-0526 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 - 4 Replace PFUDB. |
Error code: | C-0527 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7 and PFUDB at a time. |
Error code: | C-0528 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7. - 4 Replace PFUDB. |
Error code: | C-0529 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11 and PFUDB at a time. |
Error code: | C-0530 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11. - 4 Replace PFUDB. |
Error code: | C-0531 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr1 (FM4: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM4 and PFUDB at a time. |
Error code: | C-0532 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr1 (FM4: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM4 - 4 Replace PFUDB. |
Error code: | C-0533 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr2 (FM8: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM8 and PFUDB at a time. |
Error code: | C-0534 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr2 (FM8: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM8. - 4 Replace PFUDB. |
Error code: | C-0535 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr3 (FM12: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM12 and PFUDB at a time. |
Error code: | C-0536 |
Description: | 2nd tandem PF-703 paper leading edge separation fan /Rr3 (FM12) rotation abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr3 (FM12: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM12. - 4 Replace PFUDB. |
Error code: | C-0537 |
Description: | 2nd tandem PF-703 paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /1 (FM13: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM13 and PFUDB at a time. |
Error code: | C-0538 |
Description: | 2nd tandem PF-703 paper suction fan /1 (FM13) rotation abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /1 (FM13: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM13. - 4 Replace PFUDB. |
Error code: | C-0539 |
Description: | 2nd tandem PF-703 paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /3 (FM15: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM15 and PFUDB at a time. |
Error code: | C-0540 |
Description: | 2nd tandem PF-703 paper suction fan /3 (FM15) rotation abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /3 (FM15: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM15. - 4 Replace PFUDB. |
Error code: | C-0541 |
Description: | 2nd tandem PF-703 paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /5 (FM17: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM17 and PFUDB at a time. |
Error code: | C-0542 |
Description: | 2nd tandem PF-703 paper suction fan /5 (FM17) rotation abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /5 (FM17: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM17. - 4 Replace PFUDB. |
Error code: | C-0543 |
Description: | 2nd tandem PF-703 paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /2 (FM14: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM14 and PFUDB at a time. |
Error code: | C-0544 |
Description: | 2nd tandem PF-703 paper suction fan /1 (FM14) rotation abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /2 (FM14: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM14. - 4 Replace PFUDB. |
Error code: | C-0545 |
Description: | 2nd tandem PF-703 paper suction fan /3 (FM16) power abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /4 (FM16: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM16 and PFUDB at a time. |
Error code: | C-0546 |
Description: | 2nd tandem PF-703 paper suction fan /3 (FM16) rotation abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /4 (FM16: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM16. - 4 Replace PFUDB. |
Error code: | C-0547 |
Description: | 2nd tandem PF-703 paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /6 (FM18: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM18 and PFUDB at a time. |
Error code: | C-0548 |
Description: | 2nd tandem PF-703 paper suction fan /5 (FM18) rotation abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /6 (FM18: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM18. - 4 Replace PFUDB. |
Error code: | C-0561 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 and PFUDB at a time. |
Error code: | C-0562 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 - 4 Replace PFUDB. |
Error code: | C-0563 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7 and PFUDB at a time. |
Error code: | C-0564 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7. - 4 Replace PFUDB. |
Error code: | C-0565 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11 and PFUDB at a time. |
Error code: | C-0566 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11. - 4 Replace PFUDB. |
Error code: | C-0567 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr1 (FM4: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM4 and PFUDB at a time. |
Error code: | C-0568 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr1 (FM4: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM4 - 4 Replace PFUDB. |
Error code: | C-0569 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr2 (FM8: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM8 and PFUDB at a time. |
Error code: | C-0570 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr2 (FM8: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM8. - 4 Replace PFUDB. |
Error code: | C-0571 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper leading edge separation fan /Rr3 (FM12: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM12 and PFUDB at a time. |
Error code: | C-0572 |
Description: | PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) rotation abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper leading edge separation fan /Rr3 (FM12: PF- 703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM12. - 4 Replace PFUDB. |
Error code: | C-0573 |
Description: | PI-PFU (PF-703) paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /1 (FM13: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM13 and PFUDB at a time. |
Error code: | C-0574 |
Description: | PI-PFU (PF-703) paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /1 (FM13: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM13. - 4 Replace PFUDB. |
Error code: | C-0575 |
Description: | PI-PFU (PF-703) paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /3 (FM15: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM15 and PFUDB at a time. |
Error code: | C-0576 |
Description: | PI-PFU (PF-703) paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /3 (FM15: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM15. - 4 Replace PFUDB. |
Error code: | C-0577 |
Description: | PI-PFU (PF-703) paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /5 (FM17: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM17 and PFUDB at a time. |
Error code: | C-0578 |
Description: | PI-PFU (PF-703) paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /5 (FM17: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM17. - 4 Replace PFUDB. |
Error code: | C-0579 |
Description: | PI-PFU (PF-703) paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /2 (FM14: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM14 and PFUDB at a time. |
Error code: | C-0580 |
Description: | PI-PFU (PF-703) paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /2 (FM14: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 14-L 3 Replace FM14. - 4 Replace PFUDB. |
Error code: | C-0581 |
Description: | PI-PFU (PF-703) paper suction fan /3 (FM16) power abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /4 (FM16: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM16 and PFUDB at a time. |
Error code: | C-0582 |
Description: | PI-PFU (PF-703) paper suction fan /3 (FM16) power abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /4 (FM16: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM16. - 4 Replace PFUDB. |
Error code: | C-0583 |
Description: | PI-PFU (PF-703) paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Paper suction fan /6 (FM18: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM18 and PFUDB at a time. |
Error code: | C-0584 |
Description: | PI-PFU (PF-703) paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Paper suction fan /6 (FM18: PF-703) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace FM18. - 4 Replace PFUDB. |
Error code: | C-0601 |
Description: | 1st tandem PF-703 dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt1 (FM22: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 9-B 3 Replace the fun heater (FM22). - 4 Replace PFUDB. |
Error code: | C-0602 |
Description: | 1st tandem PF-703 dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt1 (FM23: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 10-C 3 Replace the fun heater (FM23). - 4 Replace PFUDB. |
Error code: | C-0603 |
Description: | 1st tandem PF-703 dehumidifier fan /Rt2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt2 (FM24: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 10-C 3 Replace the fun heater (FM24). - 4 Replace PFUDB. |
Error code: | C-0604 |
Description: | 1st tandem PF-703 dehumidifier fan /Lt2 (FM25) rotation abnormality. The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt2 (FM25: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-C 3 Replace the fun heater (FM25). - 4 Replace PFUDB. |
Error code: | C-0605 |
Description: | 1st tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt3 (FM26: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-D 3 Replace the fun heater (FM26). - 4 Replace PFUDB. |
Error code: | C-0606 |
Description: | 1st tandem PF-703 dehumidifier fan /Lt3 (FM27) rotation abnormality. The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt3 (FM27: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 12-D 3 Replace the fun heater (FM27). - 4 Replace PFUDB. |
Error code: | C-0611 |
Description: | 2nd tandem PF-703 dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt1 (FM22: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 9-B 3 Replace the fun heater (FM22). - 4 Replace PFUDB. |
Error code: | C-0612 |
Description: | 2nd tandem PF-703 dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt1 (FM23: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 10-C 3 Replace the fun heater (FM23). - 4 Replace PFUDB. |
Error code: | C-0613 |
Description: | 2nd tandem PF-703 dehumidifier fan /Rt2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt2 (FM24: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 10-C 3 Replace the fun heater (FM24). - 4 Replace PFUDB. |
Error code: | C-0614 |
Description: | 2nd tandem PF-703 dehumidifier fan /Lt2 (FM25) rotation abnormality. The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt2 (FM25: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-C 3 Replace the fun heater (FM25). - 4 Replace PFUDB. |
Error code: | C-0615 |
Description: | 2nd tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt3 (FM26: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-D 3 Replace the fun heater (FM26). - 4 Replace PFUDB. |
Error code: | C-0616 |
Description: | 2nd tandem PF-703 dehumidifier fan /Lt3 (FM27) rotation abnormality. The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt3 (FM27: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 12-D 3 Replace the fun heater (FM27). - 4 Replace PFUDB. |
Error code: | C-0621 |
Description: | PI-PFU (PF-703) dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt1 (FM22: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 9-B 3 Replace the fun heater (FM22). - 4 Replace PFUDB. |
Error code: | C-0622 |
Description: | PI-PFU (PF-703) dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt1 (FM23: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 10-C 3 Replace the fun heater (FM23). - 4 Replace PFUDB. |
Error code: | C-0623 |
Description: | PI-PFU (PF-703) dehumidifier fan /Rt2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt2 (FM24: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 10-C 3 Replace the fun heater (FM24). - 4 Replace PFUDB. |
Error code: | C-0624 |
Description: | PI-PFU (PF-703) dehumidifier fan /Lt2 (FM25) rotation abnormality. The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt2 (FM25: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-C 3 Replace the fun heater (FM25). - 4 Replace PFUDB. |
Error code: | C-0625 |
Description: | PI-PFU (PF-703) dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Rt3 (FM26: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-D 3 Replace the fun heater (FM26). - 4 Replace PFUDB. |
Error code: | C-0626 |
Description: | PI-PFU (PF-703) dehumidifier fan /Lt3 (FM27) rotation abnormality. The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Dehumidifier fan /Lt3 (FM27: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 12-D 3 Replace the fun heater (FM27). - 4 Replace PFUDB. |
Error code: | C-0631 |
Description: | 1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0632 |
Description: | 1st tandem PF-703 dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0633 |
Description: | 1st tandem PF-703 dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0634 |
Description: | 1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature software abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105C. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0635 |
Description: | 1st tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0636 |
Description: | 1st tandem PF-703 dehumidification heater /3 (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0637 |
Description: | 1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature software abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0638 |
Description: | 1st tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0639 |
Description: | 1st tandem PF-703 dehumidification heater /3 (HTR3) high temperature software abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0 °C a specified period of time after the heater is turned ON. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0640 |
Description: | 1st tandem PF-703 dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0641 |
Description: | 1st tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0642 |
Description: | 1st tandem PF-703 dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0651 |
Description: | 2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0652 |
Description: | 2nd tandem PF-703 dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Error code: | C-0653 |
Description: | 2nd tandem PF-703 dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0654 |
Description: | 2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature software abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0655 |
Description: | 2nd tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0656 |
Description: | 2nd tandem PF-703 dehumidification heater /3 (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0657 |
Description: | 2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature software abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0658 |
Description: | 2nd tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0659 |
Description: | 2nd tandem PF-703 dehumidification heater /3 (HTR3) low temperature software abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | • Lower tray fan heater (HT-505) • AC drive board /2 (ACDB/2: HT-505) • PF drive board (PFUDB: PF-703) |
Remedy: | 1. Check the connection between ACDB/2 and the noise filter of PF-703. 2. Check the connector connection and the wiring between ACDB /2 and the fan heater, and repair it if any abnormality. 3. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 4. Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. 5. Check the temperature and the installation of the fan heater, and repair it if any abnormality. 6. Replace the fan heater. 7. Replace ACDB/2. 8. Replace PFUDB. |
Error code: | C-0660 |
Description: | 2nd tandem PF-703 dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0661 |
Description: | 2nd tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0662 |
Description: | 2nd tandem PF-703 dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0671 |
Description: | PI-PFU (PF-703) dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0672 |
Description: | PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0673 |
Description: | PI-PFU (PF-703) dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0674 |
Description: | PI-PFU (PF-703) dehumidification heater /1 (HTR1) high temperature software abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0675 |
Description: | PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0676 |
Description: | PI-PFU (PF-703) dehumidification heater /3 (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB. |
Error code: | C-0677 |
Description: | PI-PFU (PF-703) dehumidification heater /1 (HTR1) low temperature software abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0678 |
Description: | PI-PFU (PF-703) dehumidification heater /2 (HTR2) low temperature software abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0679 |
Description: | PI-PFU (PF-703) dehumidification heater /3 (HTR3) low temperature software abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0680 |
Description: | PI-PFU (PF-703) dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0681 |
Description: | PI-PFU (PF-703) dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-0682 |
Description: | PI-PFU (PF-703) dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Causes: | Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703) |
Remedy: | 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB. |
Error code: | C-1001 |
Description: | Communication error. |
Causes: | Confirmation of the wiring harness and the connector FS control board (FSCB) Printer control board (PRCB: main body) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all the power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. - 4 Rewrite the firmware of the option. - 5 Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1005 |
Description: | Communication error between the main body and FS. |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all the power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. - 4 Rewrite the firmware of the option. - 5 Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1006 |
Description: | Communication error between the main body and FD. |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all the power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. - 4 Rewrite the firmware of the option. - 5 Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1007 |
Description: | Communication error between the main body and SD. |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all the power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. - 4 Rewrite the firmware of the option. - 5 Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1009 |
Description: | Communication error 1. Communication error between Main CPU in the PB control board (PBCB) and Sub CPU1. |
Causes: | PB control board (PBCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection of the control board and the drive board in PB, and repair it if any abnormality. - 3 Rewrite the firmware of PB. - 4 Replace PBCB. |
Error code: | C-1010 |
Description: | Communication error 2. Communication error between Main CPU in the PB control board (PBCB) and Sub CPU2. |
Causes: | PB control board (PBCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection of the control board and the drive board in PB, and repair it if any abnormality. - 3 Rewrite the firmware of PB. - 4 Replace PBCB. |
Error code: | C-1011 |
Description: | Communication error between the main body and PB. |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all the power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. - 4 Rewrite the firmware of the option. - 5 Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1012 |
Description: | Communication error. |
Causes: | Confirmation of the wiring harness and the connector Printer control board (PRCB) Punch Controller PCB |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all the power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. - 4 Rewrite the firmware of the option. - 5 Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1013 |
Description: | Communication error. |
Causes: | • Printer control board (PRCB) • RU control board (RUCB) |
Remedy: | 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1014 |
Description: | Communication error. |
Causes: | • Printer control board (PRCB) • RU control board (RUCB) |
Remedy: | 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1017 |
Description: | GP : GP-502 abnormality |
Causes: | • Printer control board (PRCB) • Main PCB |
Remedy: | 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the all the power plugs. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1102 |
Description: | After start-up of the main tray up/ down motor (M3) operation, the main tray upper limit sensor (PS2) or the stapler paper exit upper limit sensor (PS7) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the main tray drive parts Main tray upper limit sensor (PS2) Stapler paper exit upper limit sensor (PS7) Main tray up/down motor (M3) FS control board (FSCB) |
Remedy: | 1 Check the tray up/down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the sensor operation, LED emission and light-receiving path, and repair/ replace it if any abnormality. FS-521: 2-B, 4-B 5 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 1-B 6 Replace PS3. - 7 Replace LED1 and PS16. - 8 Replace M3. - 9 Replace FNSDB. - 10 Replace FNSCB. |
Error code: | C-1103 |
Description: | After start-up of the alignment motor /Up (M5) operation, the alignment home sensor /Up (PS8) does not turn OFF within a specified period of time. Or, it does not turn ON after being turned OFF. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the alignment plate drive parts Alignment plate home sensor /Up (PS8) Alignment motor /Up (M5) Relay board (RB) FS control board (FSCB) |
Remedy: | 1. Check the alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 5-F) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 10-B) 5. Replace PS12. 6. Replace M9. 7. Replace FNSCB. |
Error code: | C-1105 |
Description: | After start-up of the paper exit opening motor (M8) operation, the open/close operation is not completed within a specified period of time. (The paper exit opening home sensor (PS12) does not turn ON or OFF. ) |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the exit opening drive parts Paper exit opening home sensor (PS12) Paper exit opening motor (M8) FS control board (FSCB) |
Remedy: | 1 Check the paper exit opening section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 2-C 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 3-B 6 Replace PS12. - 7 Replace M8. - 8 Replace FNSDB. - 9 Replace FNSCB. |
Error code: | C-1106 |
Description: | After start-up of the stapler movement motor (M11) operation, the stapler movement home sensor (PS11) does not turn OFF. Or, it does not turn ON after being turned OFF. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the stapler movement parts Stapler movement home sensor (PS11) Stapler movement motor (M11) Relay board (RB) FS control board (FSCB) |
Remedy: | 1 Check the stapler movement section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 5-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 2-G 6 Replace PS11. - 7 Replace M11. - 8 Replace FNSDB. - 9 Replace FNSCB. - |
Error code: | C-1109 |
Description: | After start-up of the paper exit belt motor (M400) operation, the paper exit belt home sensor (PS9) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the driving parts of the conveyance belt Paper exit belt motor (M400) FS control board (FSCB) |
Remedy: | 1 Check the connector connection and the wiring between FNSDB and the stapler, and repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 3 Replacing the stapler assy - 4 Replace FNSDB. - 5 Replace FNSCB. |
Error code: | C-1113 |
Description: | The clincher home sensor /Fr (PS33) does not turn ON within a specified period of time after the clincher motor /Fr (M15) starts operation. (FS-611) |
Causes: | Confirmation of the wiring harness and the connector Replacement of the stapler / Fr Relay board (RB) FS control board (FSCB) |
Remedy: | 1 Check the stapler rotation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 4-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 2-G 6 Replace PS14. - 7 Replace M26. - 8 Replace FNSDB. - 9 Replace FNSCB. |
Error code: | C-1114 |
Description: | The clincher home sensor /Rr (PS32) does not turn ON within a specified period of time after the clincher motor /Rr (M10) starts operation. (FS-611) |
Causes: | Confirmation of the wiring harness and the connector Replacement of the stapler / Rr Relay board (RB) FS control board (FSCB) |
Remedy: | 1. Check the stacker section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 2-F) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 12-B) 5. Replace PS38. 6. Replace M28. 7. Replace FNSCB. |
Error code: | C-1115 |
Description: | Within a specified period of time after the start-up of the FS conveyance motor (M1) operation, the motor does not get to the predetermined speed. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the conveyance drive parts FS conveyance motor (M1) FS control board (FSCB) |
Remedy: | 1. Check the half-fold/fold&staple/tri-fold section, and repair it if any abnormality 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 8-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 9-B) 6. Replace PS110. 7. Replace M107. 8. Replace SDCB. 9. Replace FNSCB. |
Error code: | C-1124 |
Description: | The tray upper limit sensor /Lw (PS209) or the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time after the tray lift motor /Lw (M202) turns ON. |
Causes: | • FNS control board (FNSCB) • PI drive board (PIDB) • Tray lift motor /Lw (M202) • Tray upper limit sensor / Lw (PS209) • Tray lower limit sensor / Lw (PS210) DIPSW47-3 |
Remedy: | 1. Check the PI lower tray section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between FNSCB and PIDB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PI: 5-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PI: 6-B) 6. Replace M202. 7. Replace PS209. 8. Replace PS210. 9. Replace PIDB. 10. Replace FNSCB. |
Error code: | C-1125 |
Description: | After the folding blade motor (M19) starts the home position detection operation, the folding blade home sensor /Lw (PS22) does not turn ON within a specified period of time. (FS-611 only) |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the folding blade drive parts Folding blade home sensor (PS22) Folding blade motor (M19) Relay board (RB) FS control board (FSCB) |
Remedy: | 1. Check the PI lower tray section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between FNSCB and PIDB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PI: 4-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PI: 4-B) 6. Replace M201. 7. Replace PS204. 8. Replace PS205. 9. Replace PIDB. 10. Replace FNSCB. |
Error code: | C-1127 |
Description: | The punch shift home sensor (PS303) does not turn ON within a specified period of time after the punch shift motor (M302) turns ON. |
Causes: | • FNS control board (FNSCB) • Punch drive board (PDB) • Punch shift motor (M302) • Punch shift home sensor (PS303) DIPSW35-2 |
Remedy: | 1. Check the punch kit, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between FNSCB and PDB and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PK:7-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 6. Replace M302. 7. Replace PS303. 8. Replace PDB. 9. Replace FNSCB. |
Error code: | C-1130 |
Description: | 1st folding stopper home sensor (PS603) does not turned ON within a specified period of time after the 1st folding stopper motor (M602) starts the home position search operation. |
Causes: | • ZU control board (ZUCB) • 1st folding stopper motor (M602) • 1st folding stopper home sensor (PS603) DIPSW47-5 |
Remedy: | 1. Check the connector connection and the wiring between ZUCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 2-B) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 3-B) 4. Replace PS603. 5. Replace M602. 6. Replace ZUCB. |
Error code: | C-1131 |
Description: | After start-up of the conveyance motor (M101) operation, the M101 does not get to the predetermined speed within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the trimming conveyance drive parts Conveyance motor (M101) TU drive board (TUDB) |
Remedy: | 1. Check the connector connection and the wiring between ZUCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 2-B) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 3-B) 4. Replace PS604. 5. Replace M603. 6. Replace ZUCB. |
Error code: | C-1132 |
Description: | After the blade motor (M102) starts the home position detection operation, the blade home switch (MS101) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the blade drive parts Blade home switch (MS101) Blade motor (M102) TU drive board (TUDB) |
Remedy: | 1. Check the punch kit, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between FNSCB and PDB and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PK:5-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 6. Replace M301. 7. Replace PS301 and PS302. 8. Replace PDB. 9. Replace FNSCB. |
Error code: | C-1133 |
Description: | After the stopper motor (M103) starts the home position detection operation, the stopper home sensor (PS103) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the stopper drive parts Stopper home sensor (PS103) Stopper motor (M103) TU drive board (TUDB) |
Remedy: | 1. Check the connector connection and the wiring between ZUCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 1-B) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 4-B) 4. Replace PS605. 5. Replace M605. 6. Replace ZUCB. |
Error code: | C-1134 |
Description: | After the stopper release motor (M104) starts the home position detection operation, the stopper release home sensor (PS104) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the stopper release drive parts Stopper release home sensor (PS104) Stopper release motor (M104) TU drive board (TUDB) |
Remedy: | 1. Check the connector connection and the wiring between ZUCB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: ZU-608: 6-B) 3. Replace FM601. 4. Replace ZUCB. |
Error code: | C-1135 |
Description: | After the press motor (M105) starts the home position detection operation, the press home sensor (PS105) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the press drive parts Press home sensor (PS105) Press motor (M105) TU drive board (TUDB) |
Remedy: | 1. Check the connector connection and the wiring between ZUCB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 5-B) 3. Replace M604. 4. Replace ZUCB. |
Error code: | C-1136 |
Description: | After the pusher motor (M107) starts the home position detection operation, the pusher home sensor (PS112) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the pusher drive parts Pusher home sensor (PS112) Pusher motor (M107) TU drive board (TUDB) |
Remedy: | 1. Check the connector connection and the wiring between ZUCB and motor/switch, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 5-B) 3. Check I/O and the operation of the punch hole switching, and repair/replace it if any ab normality. (Wiring diagram: ZU-608: 5-B) 4. Replace MS601. 5. Replace M608. 6. Replace ZUCB. |
Error code: | C-1137 |
Description: | After the holder motor (M106) starts the home position detection operation, the upper limit sensor (PS110) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the holder drive parts Upper limit sensor (PS110) Holder motor (M106) TU drive board (TUDB) |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 1-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 2-B) 4. Replace PS31. 5. Replace M22. 6. Replace FNSCB. |
Error code: | C-1141 |
Description: | After start-up of the tray lift motor /Lw (M202) operation, the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the tray /Lw drive parts Tray lower limit sensor /Lw (PS210) Tray lift motor /Lw (M202) PI drive board (PIDB) FS control board (FSCB) |
Remedy: | 1 Check the stapler rotation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 5-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 3-B 6 Replace PS32. - 7 Replace M24. - 8 Replace FNSDB. - 9 Replace FNSCB. |
Error code: | C-1144 |
Description: | After the punch shift motor (M802) starts the home position search, the punch shift home sensor (PS803) does not turn ON even when a specified period of time elapses. |
Causes: | Confirmation of the wiring harness and the connector Punch shift home sensor (PS803) Punch shift motor (M802) Punch drive board (PDB) FS control board (FSCB) |
Remedy: | 1 Check the front side of the paper exit alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 8-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 7-G 6 Replace PS18. - 7 Replace M15. - 8 Replace FNSDB. - 9 Replace FNSCB. |
Error code: | C-1147 |
Description: | Paper exit alignment plate retraction motor (M18) drive abnormality. The paper exit alignment plate home sensor (PS24) does not turn ON even after a specified period of time after M18 starts the home position search operation. Or, even after a specified period of time after M18 starts the operation, it does not stop. 35-1 |
Causes: | Paper exit alignment plate retraction home sensor (PS24: FS-521) Paper exit alignment plate retraction motor (M18: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521) |
Remedy: | 1 Check the paper exit alignment retraction section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 7-M 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 4-G 6 Replace PS24. - 7 Replace M18. - 8 Replace FNSDB. - 9 Replace FNSCB. |
Error code: | C-1153 |
Description: | After the 2nd stopper motor (M3) starts the home position search, the 2nd stopper home sensor (PS4) does not turn ON even when a specified period of time elapses. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the 2nd stopper drive parts 2nd stopper home sensor (PS4) 2nd stopper motor (M3) ZU control board (ZUCB) |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 3-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 6-B) 4. Replace PS23. 5. Replace M15. 6. Replace FNSCB. |
Error code: | C-1154 |
Description: | The punch home sensor (PS801) does not turn OFF within a specified period of time after the punch motor (M801) starts operation. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the punch drive parts Punch home sensor (PS801) Punch motor (M801) Punch drive board (PDB) FS control board (FSCB) |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 2-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 4-B) 4. Replace PS24. 5. Replace M16. 6. Replace FNSCB. |
Error code: | C-1155 |
Description: | After the punch shift motor (M5) starts the home position search, the punch shift home sensor (PS5) does not turn ON even when a specified period of time elapses. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the punch shift drive parts Punch shift home sensor (PS5) Punch shift motor (M5) ZU control board (ZUCB) |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 3-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 6-B) 4. Replace PS25. 5. Replace M17. 6. Replace FNSCB. |
Error code: | C-1156 |
Description: | After the stacker rear stopper motor (M20) turns ON, the stacker rear stopper home sensor (PS29) does not turn ON within a specified period of time. |
Causes: | • FNS control board (FNSCB) • Stacker rear stopper motor (M20) • Stacker rear stopper home sensor (PS29) DIPSW35-0 |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 5-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 11-B) 4. Replace PS29. 5. Replace M20 6. Replace FNSCB. |
Error code: | C-1157 |
Description: | After the punch motor (M4) turns on, the punch operation is not completed even when a specified period of time elapses. (The punch home sensor (PS6) does not turn OFF, or it does not turn ON after being turned OFF. ) |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the punch drive parts Punch home sensor (PS6) Punch clutch (CL1) Punch motor (M4) ZU control board (ZUCB) |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 6-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 11-B) 4. Replace PS30. 5. Replace M21. 6. Replace FNSCB. |
Error code: | C-1158 |
Description: | After the punch switching motor (M8) starts the home position search, the punch switching switch (MS2) does not turn ON even when a specified period of time elapses. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the punch switchover drive parts Punch switchover switch (MS2) Punch switchover motor (M8) ZU control board (ZUCB) |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 6-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 11-B) 4. Replace PS34. 5. Replace M27. 6. Replace FNSCB. |
Error code: | C-1159 |
Description: | The bypass gate home sensor (PS36) does not turn ON within a specified period of time after the bypass gate motor (M25) turns ON. |
Causes: | • FNS control board (FNSCB) • Bypass gate motor (M25) • Bypass gate home sensor (PS36) DIPSW35-0, DIPSW47-2 |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 1-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 2-B) 4. Replace PS36. 5. Replace M25 6. Replace FNSCB. |
Error code: | C-1170 |
Description: | The exit paper press home sensor (PS37) does not turn ON within a specified period of time after the exit paper press motor (M26) turns ON. |
Causes: | • FNS control board (FNSCB) • Exit paper press motor (M26) • Exit paper press home sensor (PS37) DIPSW35-1 |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 3-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 7-B) 4. Replace PS37 5. Replace M26. 6. Replace FNSCB. |
Error code: | C-1171 |
Description: | The small size paper alignment home sensor (PS26) does not turn ON within a specified period of time after the small size paper alignment motor (M18) turns ON. |
Causes: | • FNS control board (FNSCB) • Small size paper alignment motor (M18) • Small size paper alignment home sensor (PS26) DIPSW35-0 |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 5-F) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 11-B) 4. Replace PS26. 5. Replace M18. 6. Replace FNSCB. |
Error code: | C-1172 |
Description: | An error detection signal of FM1 is detected continuously for a specified period of time while the large size paper alignment fan (FM1) is ON. |
Causes: | • FNS control board (FNSCB) • Large size paper alignment fan (FM1) DIPSW35-0 |
Remedy: | 1. Check the connector connection and the wiring between FNSCB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: FS-532: 6-F) 3. Replace FM1. 4. Replace FNSCB. |
Error code: | C-1173 |
Description: | The stapler shift home sensor (PS105) does not turn ON within a specified period of time after the stapler movement motor (M103) turns ON. |
Causes: | • FNS control board (FNSCB) • SD control board (SDCB) • Stapler movement motor (M103) • Stapler shift home sensor (PS105) DIPSW47-2 |
Remedy: | 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 2-G) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 3-B) 5. Replace PS105. 6. Replace M103. 7. Replace SDCB. 8. Replace FNSCB. |
Error code: | C-1174 |
Description: | The operation does not complete within a specified period of time after the SD saddle stapler motor (M102) starts operations, |
Causes: | • FNS control board (FNSCB) • SD control board (SDCB) • SD stapler motor (M102) DIPSW47-2 |
Remedy: | 1. Check the connector connection and the wiring between SDCB and the motor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 4-G) 4. Replace M102. 5. Replace SDCB. 6. Replace FNSCB. |
Error code: | C-1175 |
Description: | After the stopper motor (M105) turns ON, the stopper home sensor (PS107) does not turn ON within a specified period of time. |
Causes: | • FNS control board (FNSCB) • SD control board (SDCB) • Stopper motor (M105) • Stopper home sensor (PS107) DIPSW47-2 |
Remedy: | 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 1-G) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 6-B) 5. Replace PS107. 6. Replace M105. 7. Replace SDCB. 8. Replace FNSCB. |
Error code: | C-1176 |
Description: | After the center paddle motor (M106) turns ON, the center paddle home sensor (PS108) does not turn ON within a specified period of time. |
Causes: | • FNS control board (FNSCB) • SD control board (SDCB) • Center paddle motor (M106) • Center paddle home sensor (PS108) DIPSW47-2 |
Remedy: | 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 3-G) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 4-B) 5. Replace PS108. 6. Replace M106. 7. Replace SDCB. 8. Replace FNSCB. |
Error code: | C-1177 |
Description: | The 2nd folding knife home sensor (PS111) does not turn ON within a specified period of time after the 2nd folding knife motor (M110) turns ON. |
Causes: | • FNS control board (FNSCB) • SD control board (SDCB) • 2nd folding knife motor (M110) • 2nd folding knife home sensor (PS111) DIPSW47-2 |
Remedy: | 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 5-G) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 6-G) 5. Replace PS111. 6. Replace M110. 7. Replace SDCB. 8. Replace FNSCB. |
Error code: | C-1179 |
Description: | RUKA communication error |
Causes: | FNS control board (FNSCB) |
Remedy: | 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. |
Error code: | C-1180 |
Description: | The alignment home sensor (PS106) does not turn ON within a specified period of time after the saddle stitching alignment motor (M104) turns ON. |
Causes: | • FNS control board (FNSCB) • SD control board (SDCB) • Saddle stitching alignment motor (M104) • Alignment home sensor (PS106) DIPSW47-2 |
Remedy: | 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 3-G) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 4-B) 5. Replace PS106. 6. Replace M104. 7. Replace SDCB. 8. Replace FNSCB. |
Error code: | C-1181 |
Description: | After the gate motor (M12) starts the home position search, the gate home sensor (PS16) does not turn ON even when a specified period of time elapses. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the gate drive parts Gate home sensor (PS16) Gate motor (M12) FS control board (FSCB) |
Remedy: | 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 8-B) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 7-B) 5. Replace PS114. 6. Replace M109. 7. Replace SDCB. 8. Replace FNSCB. |
Error code: | C-1201 |
Description: | 1st tandem LS-505 stacker tray up down motor (M1) drive abnormality. The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after M1 turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. 33-6 |
Causes: | Stacker tray encoder sensor (PS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-A 5 Replace PS2. - 6 Replace M1. - 7 Replace LSCB. |
Error code: | C-1202 |
Description: | 1st tandem LS-505 shift unit motor (M5) drive abnormality. The shift unit home sensor (PS11) does not turn OFF within a specified period of time after M5 turns ON. Or, PS11 does not turn ON within a specified period of time. 33-6 |
Causes: | Shift unit home sensor (PS11: LS-505) Shift unit motor (M5: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the shift unit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS11. - 6 Replace M5. - 7 Replace LSCB. |
Error code: | C-1203 |
Description: | 1st tandem LS-505 alignment motor (M7) drive abnormality. The alignment plate home sensor (PS12) does not turn ON within a specified period of time after M7 turns ON. Or, PS12 does not turn ON within a specified period of time. 33-6 |
Causes: | Alignment plate home sensor (PS12: LS-505) Alignment motor (M7: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 7-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS12. - 6 Replace M7. - 7 Replace LSCB. |
Error code: | C-1204 |
Description: | 1st tandem LS-505 grip conveyance motor (M4) drive abnormality. The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after M4 turns ON. 33-6 |
Causes: | Grip conveyance home sensor (PS5: LS-505) Grip conveyance motor (M4: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the grip conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 2-H 5 Replace PS5. - 6 Replace M4. - 7 Replace LSCB. |
Error code: | C-1205 |
Description: | 1st tandem LS-505 stacker tray upper limit abnormality. The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. 33-6 |
Causes: | Stacker tray upper limit switch (MS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS2. - 6 Replace M1. - 7 Replace LSCB. |
Error code: | C-1206 |
Description: | 1st tandem LS-505 stacker tray lower limit abnormality. The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. 33-6 |
Causes: | Stacker tray lower limit switch (MS3: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS3. - 6 Replace M1. - 7 Replace LSCB. |
Error code: | C-1211 |
Description: | 2nd tandem PF-505 stacker tray up down motor (M1) drive abnormality. The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after M1 turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. 33-7 |
Causes: | Stacker tray encoder sensor (PS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-A 5 Replace PS2. - 6 Replace M1. - 7 Replace LSCB. |
Error code: | C-1212 |
Description: | 2nd tandem LS-505 shift unit motor (M5) drive abnormality. The shift unit home sensor (PS11) does not turn OFF within a specified period of time after M5 turns ON. Or, PS11 does not turn ON within a specified period of time. 33-7 |
Causes: | Shift unit home sensor (PS11: LS-505) Shift unit motor (M5: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the shift unit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS11. - 6 Replace M5. - 7 Replace LSCB. |
Error code: | C-1213 |
Description: | 2nd tandem LS-505 alignment motor (M7) drive abnormality. The alignment plate home sensor (PS12) does not turn ON within a specified period of time after M7 turns ON. Or, PS12 does not turn ON within a specified period of time. 33-7 |
Causes: | Alignment plate home sensor (PS12: LS-505) Alignment motor (M7: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 7-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS12. - 6 Replace M7. - 7 Replace LSCB. |
Error code: | C-1214 |
Description: | 2nd tandem LS-505 grip conveyance motor (M4) drive abnormality. The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after M4 turns ON. 33-7 |
Causes: | Grip conveyance home sensor (PS5: LS-505) Grip conveyance motor (M4: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the grip conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 2-H 5 Replace PS5. - 6 Replace M4. - 7 Replace LSCB. |
Error code: | C-1215 |
Description: | 2nd tandem LS-505 stacker tray upper limit abnormality. The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. 33-7 |
Causes: | Stacker tray upper limit switch (MS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS2. - 6 Replace M1. - 7 Replace LSCB. |
Error code: | C-1216 |
Description: | 2nd tandem LS-505 stacker tray lower limit abnormality. The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. 33-7 |
Causes: | Stacker tray lower limit switch (MS3: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS3. - 6 Replace M1. - 7 Replace LSCB. |
Error code: | C-1221 |
Description: | 1st folding release motor (M14) drive abnormality. The 1st folding cam home sensor (PS55) does not turn ON within a specified period of time after M14 turns ON. 33-0 |
Causes: | 1st folding cam home sensor (PS55: FD-503) 1st folding release motor (M14: FD-503) Folding drive board (FDB: FD-503) |
Remedy: | 1 Check the 1st folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 2-B 5 Replace PS55. - 6 Replace M14. - 7 Replace FDB. |
Error code: | C-1222 |
Description: | 2nd folding release motor (M15) drive abnormality. The 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time after M15 turns ON. 33-0 |
Causes: | 2nd folding cam home sensor (PS56: FD-503) 2nd folding release motor (M15: FD-503) Folding drive board (FDB: FD-503) |
Remedy: | 1 Check the 2nd folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 2-B 5 Replace PS56. - 6 Replace M15. - 7 Replace FDB. |
Error code: | C-1223 |
Description: | 3rd folding release motor (M16) drive abnormality. The 3rd folding cam home sensor (PS57) does not turn ON within a specified period of time after M16 turns ON. 33-0 |
Causes: | 3rd folding cam home sensor (PS57: FD-503) 3rd folding release motor (M16: FD-503) Folding drive board (FDB: FD-503) |
Remedy: | 1 Check the 3rd folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 2-B 5 Replace PS57. - 6 Replace M16. - 7 Replace FDB. |
Error code: | C-1224 |
Description: | 2-hole operation abnormality. The 2-holes punch home sensor (PS8) does not turn OFF within a specified period of time after the 2-holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 2- holes punch home sensor (PS8) does not turn OFF. 33-0 |
Causes: | 2 holes punch home sensor (PS8: FD-503) Punch motor (M10: FD-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the 2-hole punch section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 5-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-E 5 Replace PS8. - 6 Replace M10. - 7 Replace PDB. |
Error code: | C-1225 |
Description: | 3-hole/4-hole punch operation abnormality. The 3 holes/4 holes punch home sensor (PS9) does not turn OFF within a specified period of time after the 3 holes/4 holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 3 holes/4 holes punch home sensor (PS9) does not turn OFF. 33-0 |
Causes: | 3 holes/4 holes punch home sensor (PS9: FD-503) Punch motor (M10: FD-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the 3-hole/4-hole punch section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 5-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-E 5 Replace PS9. - 6 Replace M10. - 7 Replace PDB. |
Error code: | C-1226 |
Description: | Punch alignment plate operation abnormality. The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF. 33-0 |
Causes: | Alignment plate home sensor (PS10: FD-503) Alignment motor (M12: FD-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-D 5 Replace PS10. - 6 Replace M12. - 7 Replace PDB. |
Error code: | C-1227 |
Description: | Punch paper trailing edge operation abnormality. The punch registration home sensor (PS11) does not turn ON within a specified period of time after the punch registration claw home position return operation starts. Or, after the punch registration motor (M13) turns ON, the punch registration home sensor (PS11) does not turn OFF. 33-0 |
Causes: | Punch registration home sensor (PS11: FD-503) Punch registration motor (M13: FD-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 5-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-E 5 Replace PS11. - 6 Replace M13. - 7 Replace PDB. |
Error code: | C-1228 |
Description: | Exit tray operation abnormality 1. The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF. 33-2 |
Causes: | Main tray upper limit sensor (PS20: FD-503) Tray up down motor (M11: FS-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 6-D 5 Replace PS20. - 6 Replace M11. - 7 Replace PDB. |
Error code: | C-1229 |
Description: | Exit tray operation abnormality 2. The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation. 33-2 |
Causes: | Main tray lower limit sensor (PS22: FD-503) Tray up down motor (M11: FS-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 3-D 5 Replace PS22. - 6 Replace M11. - 7 Replace PDB. |
Error code: | C-1230 |
Description: | PI upper tray operation abnormality. After the FD paper lift motor /Up (M8) is in the down operation, the PI lift plate home sensor /Up (PS34) does not turn ON within a specified period of time. Or, after the paper lift motor /Up (M8) is in the up operation, the PI upper limit sensor /Up (PS32) does not turn ON. 33-3 |
Causes: | PI upper limit sensor /Up (PS32: FD-503) PI lift plate home sensor /Up (PS34: FD-503) Paper lift motor /Up (M8: FD-503) PI drive board (PIDB: FD-503) |
Remedy: | 1 Check the PI upper tray section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 9-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 8-A, 9-A 5 Replace PS32 or PS34. - 6 Replace M8. - 7 Replace PIDB. |
Error code: | C-1231 |
Description: | PI lower tray operation abnormality. After the FD paper lift motor /Lw (M9) is in the down operation, the PI lift plate home sensor /Lw (PS40) does not turn ON within a specified period of time. Or, after the paper lift motor /Lw (M9) is in the up operation, the PI upper limit sensor /Lw (PS38) does not turn ON. 33-3 |
Causes: | PI upper limit sensor /Lw (PS38: FD-503) PI lift plate home sensor /Lw (PS40: FD-503) Paper lift motor /Lw (M9: FD-503) PI drive board (PIDB: FD-503) |
Remedy: | 1 Check the PI lower tray section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 9-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 7-A, 8-A 5 Replace PS38 or PS40. - 6 Replace M9. - 7 Replace PIDB. |
Error code: | C-1232 |
Description: | Entrance conveyance motor (M1) rotation abnormality. M1 abnormality detection signal was continuously detected for the specified time when M1 was ON. |
Causes: | Entrance conveyance motor (M1: FD-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the entrance conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Replace M1. - 5 Replace PDB. |
Error code: | C-1233 |
Description: | Intermediate conveyance motor (M3) rotation abnormality. M3 abnormality detection signal was continuously detected for the specified time when M3 was ON. |
Causes: | Intermediate conveyance motor (M3: FD-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the intermediate conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 4-D 4 Replace M3. - 5 Replace PDB. |
Error code: | C-1234 |
Description: | PI conveyance motor (M7) rotation abnormality. M7 abnormality detection signal was continuously detected for the specified time when M7 was ON. 33-3 |
Causes: | PI conveyance motor (M7: FD-503) PI drive board (PIDB: FD-503) |
Remedy: | 1 Check the PI conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PIDB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 9-A 4 Replace M7. - 5 Replace PIDB. |
Error code: | C-1235 |
Description: | Main tray paper exit motor (M17) rotation abnormality. M17 abnormality detection signal was continuously detected for the specified time when M17 was ON. |
Causes: | Main tray exit motor (M17: FD-503) Punch drive board (PDB: FD-503) |
Remedy: | 1 Check the main tray exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 4-D 4 Replace M17. - 5 Replace PDB. |
Error code: | C-1241 |
Description: | Bundle exit drive motor (M5) drive abnormality. The scraps press home sensor (PS48) does not turn ON even after a specified period of time after M5 starts the home position search operation. 34-0/1/3 |
Causes: | Scraps press home sensor (PS48: SD-506) Bundle exit motor (M5: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 24-D 6 Replace PS48. - 7 Replace M5. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1242 |
Description: | Folding main scan alignment motor /Fr (M7) drive abnormality. The folding main scan alignment home sensor /Fr1 (PS18) does not turn ON even after a specified period of time after M7 starts the home position search operation. Or, even after a specified period of time after M7 starts the operation, it does not stop. 34-0/1/2/3 |
Causes: | Folding main scan alignment home sensor /Fr1 (PS18: SD-506) Folding main scan alignment motor /Fr (M7: SD- 506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the folding main scan alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 8-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 13-D 6 Replace PS18. - 7 Replace M7. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1243 |
Description: | Folding sub scan alignment exit motor (M8) The folding exit home sensor (PS24) does not turn ON even after a specified period of time after M8 starts the home position search operation. Or, even after a specified period of time after M8 starts to decelerate, it does not stop. 34-0/1/2/3 |
Causes: | Folding exit home sensor (PS24: SD-506) Folding sub scan alignment exit motor (M8: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the folding sub scan alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 10-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 14-D 6 Replace PS24. - 7 Replace M8. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1244 |
Description: | Saddle stitching alignment motor /Rt (M9) drive abnormality. The saddle stitching alignment home sensor /Rt (PS28) does not turn ON even after a specified period of time after M9 starts the home position search operation. Or, even after a specified period of time after M9 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Saddle stitching alignment home sensor /Rt (PS28: SD-506) Saddle stitching alignment motor /Rt (M9: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the saddle stitching alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 19-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 17-D 6 Replace PS28. - 7 Replace M9. - 8 Replace SDDB. - 9 Replace SDCB. - |
Error code: | C-1245 |
Description: | Bundle arm motor (M10) drive abnormality. The bundle arm home sensor (PS32) does not turn ON even after a specified period of time after M10 starts the home position search operation. Or, even after a specified period of time after M10 starts the operation, it does not stop. Bundle arm motor (M10) 34-0/1/3 |
Causes: | Bundle arm home sensor (PS32: SD-506) Bundle arm motor (M10: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle arm section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 19-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 17-D 6 Replace PS32. - 7 Replace M10. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1246 |
Description: | Bundle clip motor (M11) drive abnormality. The bundle click upper limit (PS33) does not turn ON even after a specified period of time after M11 starts the home position search operation. Or, even after a specified period of time after M11 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Bundle clip upper limit sensor (PS33: SD-506) Bundle clip motor (M11: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle clip section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 16-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 19-D 6 Replace PS33. - 7 Replace M11. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1247 |
Description: | Bundle registration motor (M12) drive abnormality. The bundle registration home sensor (PS34) does not turn ON even after a specified period of time after M12 starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Bundle registration home sensor (PS34: SD-506) Bundle registration motor (M12: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle registration section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 27-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 21-D 6 Replace PS34. - 7 Replace M12. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1248 |
Description: | Overlap motor (M13) drive abnormality. The overlap home sensor (PS17) does not turn ON even after a specified period of time after M13 starts the home position search operation. Or, even after a specified period of time after M13 starts the operation, it does not stop. 34-0/1/2/3 |
Causes: | Overlap home sensor (PS17: SD-506) Overlap motor (M13: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the overlap section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 2-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 2-D 6 Replace PS17. - 7 Replace M13. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1249 |
Description: | Folding main scan alignment motor /Rr (M14) drive abnormality. The folding main scan alignment home sensor /Rr (PS19) does not turn ON even after a specified period of time after M14 starts the home position search operation. Or, even after a specified period of time after M14 starts the operation, it does not stop. 34-0/1/2/3 |
Causes: | Folding main scan alignment home sensor /Rr (PS19: SD-506) Folding main scan alignment motor /Rr (M14: SD- 506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the folding main scan alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 12-D 6 Replace PS19. - 7 Replace M14. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1250 |
Description: | Stapler movement motor (M15) drive abnormality. The stapler movement home sensor (PS25) does not turn ON even after a specified period of time after M15 starts the home position search operation. Or, even after a specified period of time after M15 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Stapler movement home sensor (PS25: SD-506) Stapler movement motor (M15: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the stapler movement section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 15-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 18-D 6 Replace PS25. - 7 Replace M15. - 8 Replace SDDB. - 9 Replace SDCB. - |
Error code: | C-1251 |
Description: | Saddle stitching alignment motor /Lt (M16) drive abnormality. The saddle stitching alignment home sensor /Lt (PS29) does not turn ON even after a specified period of time after M16 starts the home position search operation. Or, even after a specified period of time after M16 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Saddle stitching alignment home sensor /Lt (PS29: SD-506) Saddle stitching alignment motor /Lt (M16: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the saddle stitching alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 15-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 17-D 6 Replace PS29. - 7 Replace M16. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1252 |
Description: | Bundle press movement motor (M17) drive abnormality. The bundle press movement home sensor (PS36) does not turn ON even after a specified period of time after M17 starts the home position search operation. Or, even after a specified period of time after M17 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Bundle press movement home sensor (PS36: SD- 506) Bundle press movement motor (M17: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle press movement section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 26-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 22-D 6 Replace PS36. - 7 Replace M17. - 8 Replace SDDB. - 9 Replace SDCB. - |
Error code: | C-1253 |
Description: | 1st folding blade motor (M18) drive abnormality. The 1st folding blade home sensor /2 (PS21) does not turn ON even after a specified period of time after M18 starts the home position search operation. Or 1st folding blade home sensor /1 (PS20) does not turned ON within a specified period of time after M18 starts the operation. 34-0/1/2/3 |
Causes: | 1st folding blade home sensor /1 (PS20: SD-506) 1st folding blade home sensor /2 (PS21: SD-506) 1st folding blade motor (M18: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the 1st folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 12-D 6 Replace PS20 or PS21. - 7 Replace M18. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1254 |
Description: | 2nd folding blade motor (M19) drive abnormality. The 2nd folding blade home sensor /2 (PS23) does not turn ON even after a specified period of time after M19 starts the home position search operation. Or the 2nd folding blade home sensor /1 (PS22) does not turned ON within a specified period of time after M19 starts the operation. 34-2 |
Causes: | 2nd folding blade home sensor /1 (PS22: SD-506) 2nd folding blade home sensor /2 (PS23: SD-506) 2st folding blade motor (M19: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the 2nd folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 12-D,13-D 6 Replace PS22 or PS23. - 7 Replace M19. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1255 |
Description: | Clincher up down motor (M20) drive abnormality. The clincher up down home sensor (PS26) does not turn ON even after a specified period of time after M20 starts the home position search operation. Or, even after a specified period of time after M20 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Clincher up down home sensor (PS26: SD-506) Clincher up down motor (M20: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the clincher up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 16-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 18-D 6 Replace PS26. - 7 Replace M20. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1256 |
Description: | Saddle stitching alignment motor (M21) drive abnormality. The saddle stitching press home sensor (PS27) does not turn ON even after a specified period of time after M21 starts the home position search operation. Or, even after a specified period of time after M21 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Saddle stitching press home sensor (PS27: SD-506) Saddle stitching press motor (M21: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the saddle stitching press section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 16-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 16-D 6 Replace PS27. - 7 Replace M21. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1257 |
Description: | Bundle arm rotation motor (M22) drive abnormality. The bundle arm rotation home sensor (PS31) does not turn ON even after a specified period of time after M22 starts the home position search operation. Or, even after a specified period of time after M22 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Bundle arm rotation home sensor (PS31: SD-506) Bundle arm rotation motor (M22: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle arm rotation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 27-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 24-D 6 Replace PS31. - 7 Replace M22. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1258 |
Description: | Bundle press movement motor (M23) drive abnormality. The bundle press home sensor (PS37) does not turn ON even after a specified period of time after M23 starts the home position search operation. Or, even after a specified period of time after M23 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Bundle press home sensor (PS37: SD-506) Bundle press lower limit sensor (PS47: SD-506) Bundle press motor (M23: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle press section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 20-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 23-D 6 Replace PS37 or PS47. - 7 Replace M23. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1259 |
Description: | Bundle press stage up down motor (M24) drive abnormality. The bundle press stage up down home motor (PS35) does not turn ON even after a specified period of time after M24 starts the home position search operation. Or PS35 or the bundle press stage up down upper limit sensor (PS45) does not turned ON after a specified period of time M24 starts the operation. 34-0/1/3 |
Causes: | Bundle press stage up down home sensor (PS35: SD-506) Bundle press stage up down limit sensor (PS45: SD-506) Bundle press stage up down motor (M24: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle press stage up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 21-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 24-D, 25-D 6 Replace PS35 or PS45. - 7 Replace M24. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1260 |
Description: | Guide shaft motor (M25) drive abnormality. The guide shaft home sensor (PS46) does not turn ON even after a specified period of time after M25 starts the home position search operation. Or, even after a specified period of time after M25 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Guide shaft home sensor (PS46: SD-506) Guide shaft motor (M25: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the guide shaft, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 15-D 6 Replace PS46. - 7 Replace M25. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1261 |
Description: | Stapler motor /Rt (M29) drive abnormality. Stapler home sensor /Rt (HS1) or clincher start sensor /Rt (HS2) does not turn ON even after a specified period of time after M29 starts the operation. 34-0/3 |
Causes: | Stapler assy SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the stapler assy /Rt, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the stapler assy /Rt, and repair it if any abnormality. - 3 Replacing the stapler assy /Rt - 4 Replace SDDB. - 5 Replace SDCB. |
Error code: | C-1262 |
Description: | Stapler motor /Lt (M30) drive abnormality. Stapler home sensor /Lt (HS3) or clincher start sensor /Lt (HS4) does not turn ON even after a specified period of time after M30 starts the operation. 34-0/3 |
Causes: | Stapler assy SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the stapler assy /Lt, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the stapler assy /Lt, and repair it if any abnormality. - 3 Replacing the stapler assy /Lt - 4 Replace SDDB. - 5 Replace SDCB. |
Error code: | C-1263 |
Description: | Trimmer blade motor (M31) drive abnormality. Or, even after a specified period of time after M31 starts the operation, it does not stop. 34-3 |
Causes: | Trimmer blade home sensor (PS50: SD-506) Trimmer blade upper limit sensor (PS51: SD-506) Trimmer blade motor (M31: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the trimmer blade, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 23-R 6 Replace PS50 or PS51. - 7 Replace M31. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1264 |
Description: | Trimmer press motor (M32) drive abnormality. Or, even after a specified period of time after M32 starts the operation, it does not stop. 34-3 |
Causes: | Trimmer press upper limit sensor (PS52: SD-506) Trimmer press home sensor (PS53: SD-506) Trimmer press motor (M32: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the trimmer press section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 23-R 6 Replace PS52 or PS53. - 7 Replace M32. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1265 |
Description: | Bundle arm assist motor (M26) drive abnormality. Or, even after a specified period of time after M26 starts the operation, it does not stop. 34-0/1/3 |
Causes: | Bundle arm assist home sensor (PS38: SD-506) Bundle arm assist upper limit sensor (PS39: SD- 506) Bundle arm assist motor (M26: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle arm assist section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 16-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 17-D 6 Replace PS38 or PS39. - 7 Replace M26. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1266 |
Description: | Entrance conveyance motor (M1) rotation abnormality. Rotation abnormality detected continuously for the specified time during M1 operation. |
Causes: | Entrance conveyance motor (M1: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the entrance conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 2-D 5 Replace M1. - 6 Replace SDDB. - 7 Replace SDCB. |
Error code: | C-1267 |
Description: | Horizontal conveyance motor (M2) rotation abnormality. Rotation abnormality detected continuously for the specified time during M2 operation. 34-4 |
Causes: | Horizontal conveyance motor (M2: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the horizontal conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 7-D 5 Replace M2. - 6 Replace SDDB. - 7 Replace SDCB. |
Error code: | C-1268 |
Description: | Folding entrance motor (M3) rotation abnormality. Rotation abnormality detected continuously for the specified time during M3 operation. 34-0/1/2/ 3 |
Causes: | Folding entrance motor (M3: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the folding entrance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 9-D 5 Replace M3. - 6 Replace SDDB. - 7 Replace SDCB. |
Error code: | C-1269 |
Description: | Folding conveyance motor (M4) rotation abnormality. Rotation abnormality detected continuously for the specified time during M4 operation. 34-0/1/2/ 3 |
Causes: | Folding conveyance motor (M4: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the folding conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 9-D 5 Replace M4. - 6 Replace SDDB. - 7 Replace SDCB. |
Error code: | C-1270 |
Description: | Bundle exit motor (M5) rotation abnormality. Rotation abnormality detected continuously for the specified time during M5 operation. 34-0/1/3 |
Causes: | Bundle exit motor (M5: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the bundle exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-D 5 Replace M5. - 6 Replace SDDB. - 7 Replace SDCB. |
Error code: | C-1271 |
Description: | Folding sub scan alignment exit motor (M8) rotation abnormality. Rotation abnormality detected continuously for the specified time during M8 operation. 34-0/1/2/ 3 |
Causes: | Folding sub scan alignment exit motor (M8: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the folding sub scan alignment exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 10-D 5 Replace M8. - 6 Replace SDDB. - 7 Replace SDCB. |
Error code: | C-1272 |
Description: | Paddle motor (M33) rotation abnormality. Rotation abnormality detected continuously for the specified time during M33 operation. 34-3 |
Causes: | Trimmer paddle motor (M33: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the trimmer paddle, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-W 4 Replace M33. - 5 Replace SDCB. |
Error code: | C-1273 |
Description: | Trimmer edge upper limit abnormality. The trimmer blade upper limit sensor (PS62) does not turn ON even after a specified period of time after the trimmer blade motor (M31) starts the home position search operation. 34-3 |
Causes: | Trimmer completion sensor (PS62: SD-506) Trimmer blade motor (M31: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the trimmer blade upper limit, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 10-U 6 Replace PS62. - 7 Replace M31. - 8 Replace SDDB. - 9 Replace SDCB. |
Error code: | C-1275 |
Description: | Trimmer edge drive wire abnormality. The wire slack sensor (PS62) detected the slack of the trimmer edge drive wire. 34-3 |
Causes: | Wire slack prevention sensor (PS66: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the wire slack, and repair the trimmer blade if any abnormality. - 2 Check the connector connection and the wiring between SDCB and the sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 10-U 4 Replace PS66. - 5 Replace SDCB. |
Error code: | C-1281 |
Description: | FD alignment motor (M3) drive abnormality. The FD alignment home sensor (PS3) does not turn ON even after a specified period of time after M3 starts the home position search operation. Or, even after a specified period of time after M3 starts the operation, it does not stop. |
Causes: | FD alignment home sensor (PS3: RU-506) FD alignment motor (M3: RU-506) RU control board (RUCB: RU-506) |
Remedy: | 1 Check the FD alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between RUCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. RU-506: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. RU-506: 5-B 5 Replace PS3. - 6 Replace M3. - 7 Replace RUCB |
Error code: | C-1282 |
Description: | CD alignment motor (M4) drive abnormality. The CD alignment home sensor (PS4) does not turn ON even after a specified period of time after M4 starts the home position search operation. Or, even after a specified period of time after M4 starts the operation, it does not stop. |
Causes: | CD alignment home sensor (PS4: RU-506) CD alignment motor (M4: RU-506) RU control board (RUCB: RU-506) |
Remedy: | 1 Check the CD alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between RUCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. RU-506: 2-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. RU-506: 5-B 5 Replace PS4. - 6 Replace M4. - 7 Replace RUCB |
Error code: | C-1290 |
Description: | Rotation abnormality is detected for a specified period of time in succession while the decurler conveyance motor (M3) is driving. |
Causes: | • De-curler conveyance motor (M3) • RU control board (RUCB) |
Remedy: | 1. Check the de-curler section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUCB and the motor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-509: 11-F) 4. Replace M3. 5. Replace RUCB |
Error code: | C-1291 |
Description: | The home position search operation of the de-curler pressure motor /Lw (M5) does not complete within a specified period of time. |
Causes: | • De-curler pressure motor /Lw (M5) • RU control board (RUCB) |
Remedy: | 1. Check the de-curler section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUCB and the motor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-509: 10-F) 4. Replace M5. 5. Replace RUCB |
Error code: | C-1292 |
Description: | The home position search operation of the de-curler pressure motor /Up (M6) does not complete within a specified period of time. |
Causes: | • De-curler pressure motor /Up (M6) • RU control board (RUCB) |
Remedy: | 1. Check the de-curler section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUCB and the motor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-509: 11-F) 4. Replace M6. 5. Replace RUCB |
Error code: | C-1293 |
Description: | Rotation abnormality is detected for a specified period of time in succession while the humidification section conveyance motor (M8) is driving. |
Causes: | Humidification section conveyance motor (M8) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the humidification section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-509: 13-O) 5. Replace M8. 6. Replace RUDB. 7. Replace RUCB |
Error code: | C-1294 |
Description: | The home position search operation of the humidification section roller pressure motor /Rt (M9) does not complete within a specified period of time. |
Causes: | • Humidification section roller pressure motor /Rt (M9) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the humidification section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-509: 15-O) 5. Replace M9. 6. Replace RUDB. 7. Replace RUCB |
Error code: | C-1295 |
Description: | The home position search operation of the humidification section roller pressure motor /Lt (M10) does not complete within a specified period of time. |
Causes: | • Humidification roller pressure motor /Lt (M10) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the humidification section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-509: 15-O) 5. Replace M10. 6. Replace RUDB. 7. Replace RUCB |
Error code: | C-1299 |
Description: | The water tank full sensor (PS13) detects ON continuously for more than a specified period of time. |
Causes: | • Drain path • Water tank full sensor (PS13) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the drain path, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring of RUDB, the pump motor (1) and the sensor, and repair it if any abnormality. 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: RU-509: 16-O) 4. Replace PS13. 5. Replace RUDB. |
Error code: | C-1301 |
Description: | 1st tandem LS-505 paper cooling fan motor /Fr (FM1) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM1 operation. 33-6 |
Causes: | Paper cooling fan /Fr (FM1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 4-A 3 Replace FM1. - 4 Replace LSCB. |
Error code: | C-1302 |
Description: | 1st tandem LS-505 paper cooling fan motor /1 (FM/2) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM2 operation. 33-6 |
Causes: | Paper cooling fan motor/1 (FM2: LS-505) Paper cooling fan motor/2 (FM6: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 6-H 3 Replace FM2 or FM6. - 4 Replace LSCB. |
Error code: | C-1303 |
Description: | 1st tandem LS-505 paper cooling fan motor /Mi (FM3) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM3 operation. 33-6 |
Causes: | Paper cooling fan motor/Mi (FM3: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 5-A 3 Replace FM3 - 4 Replace LSCB. |
Error code: | C-1304 |
Description: | 1st tandem LS-505 motor cooling fan motor /4 (FM) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM4 operation. 33-6 |
Causes: | Motor cooling fan motor (FM4: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 7-H 3 Replace FM4 - 4 Replace LSCB. |
Error code: | C-1305 |
Description: | 1st tandem LS-505 paper cooling fan motor /Rr (FM5) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM5 operation. 33-6 |
Causes: | Paper cooling fan motor/Rr (FM5: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 5-A 3 Replace FM5. - 4 Replace LSCB. |
Error code: | C-1306 |
Description: | 2nd tandem LS-505 paper cooling fan motor /Fr (FM1) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM1 operation. 33-7 |
Causes: | Paper cooling fan /Fr (FM1: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 4-A 3 Replace FM1. - 4 Replace LSCB. |
Error code: | C-1307 |
Description: | 2nd tandem LS-505 paper cooling fan motor /1 (FM2) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM2 operation. 33-7 |
Causes: | Paper cooling fan motor/1 (FM2: LS-505) Paper cooling fan motor/2 (FM6: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 6-H 3 Replace FM2 or FM6. - 4 Replace LSCB. |
Error code: | C-1308 |
Description: | 2nd tandem LS-505 paper cooling fan motor /Mi (FM3) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM3 operation. 33-7 |
Causes: | Paper cooling fan motor/Mi (FM3: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 5-A 3 Replace FM3 - 4 Replace LSCB. |
Error code: | C-1309 |
Description: | 2nd tandem LS-505 motor cooling fan motor (FM4) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM4 operation. 33-7 |
Causes: | Motor cooling fan motor (FM4: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 7-H 3 Replace FM4 - 4 Replace LSCB. |
Error code: | C-1310 |
Description: | 2nd tandem LS-505 paper cooling fan motor /Rr (FM5) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM5 operation. 33-7 |
Causes: | Paper cooling fan motor/Rr (FM5: LS-505) LS control board (LSCB: LS-505) |
Remedy: | 1 Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. LS-505: 5-A 3 Replace FM5. - 4 Replace LSCB. |
Error code: | C-1311 |
Description: | Scraps removal fan motor (FM1) rotation abnormality. An error detection signal is detected continuously for specified time period while FM1 is started or driving. 34-3 |
Causes: | Scraps removal fan (FM1: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506) |
Remedy: | 1 Check the connector connection and the wiring between SDDB and the fan, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. SD-506: 26-D 4 Replace FM1. - 5 Replace SDDB. - Replace SDCB. |
Error code: | C-1316 |
Description: | An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON. |
Causes: | • Paper cooling fan motor /Fr (FM1) • LS control board (LSCB) |
Remedy: | 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 4-A) 3. Replace FM1. 4. Replace LSCB. |
Error code: | C-1317 |
Description: | An error detection signal is detected continuously for a specified period of time while the paper cooling fan /1 (FM2) is ON. |
Causes: | • Paper cooling fan motor /1 (FM2) • LS control board (LSCB) |
Remedy: | 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 6-H) 3. Replace FM2 or FM6. 4. Replace LSCB. |
Error code: | C-1318 |
Description: | An error detection signal is detected continuously for a specified period of time while the paper cooling fan /Mi (FM3) is ON. |
Causes: | • Paper cooling fan motor /Mi (FM3) • LS control board (LSCB) |
Remedy: | 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 5-A) 3. Replace FM3. 4. Replace LSCB. |
Error code: | C-1319 |
Description: | An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON. |
Causes: | • Motor cooling fan motor • LS control board (LSCB) |
Remedy: | 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 7-H) 3. Replace FM4 4. Replace LSCB. |
Error code: | C-1320 |
Description: | An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan /Rr (FM5) is ON. |
Causes: | • Paper cooling fan motor /Rr (FM5) • LS control board (LSCB) |
Remedy: | 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 5-A) 3. Replace FM5. 4. Replace LSCB. |
Error code: | C-1330 |
Description: | Cover paper tray fan /1 (M71: PB-502, FM71: PB-503) drive abnormality. An error detection signal is detected continuously for specified time period while M71 is started or driving. 35-3 |
Causes: | Cover paper tray fan /1 (M71: PB-502, FM71: PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the connector connection and the wiring between PBDB/PBDB1 and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PB-502: 21-D PB-503: 21-D 3 Replace M71 (PB-502), FM71 (PB-503). - 4 Replace PBDB (PB-502), PBDB1 (PB-503). |
Error code: | C-1331 |
Description: | Cover paper tray fan /2 (M72: PB-502, FM72: PB-503) drive abnormality. An error detection signal is detected continuously for specified time period while M72 is started or driving. 35-3 |
Causes: | Cover paper tray fan /2 (M72: PB-502, FM72: PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the connector connection and the wiring between PBDB/PBDB1 and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PB-502: 21-D PB-503: 21-D 3 Replace M72 (PB-502), FM72 (PB-503). - 4 Replace PBDB (PB-502), PBDB1 (PB-503). |
Error code: | C-1332 |
Description: | Exhaust fan /1 (M80: PB-502, FM80: PB-503), deodorant fan /1 (FM97: PB-503) and deodorant fan /2 (FM98: PB-503) drive abnormality. An error detection signal is detected continuously for specified time period while M80, M97 and M98 is started or driving. 35-4 |
Causes: | Exhaust fan /1 (M80: PB-502, FM80: PB-503) Deodorant fan /1 (FM97: PB-503) Deodorant fan /2 (FM98: PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB drive board /3 (PBDB3: PB-503) |
Remedy: | 1 Check the connector connection and the wiring between PBDB/PBDB1 and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PB-502: 3-D PB-503: 3-D, 19-U 3 Replace M80 (PB-502), FM80 (PB-503), FM97 (PB-503), FM98 (PB-503). - 4 Replace PBDB (PB-502), PBDB1 (PB-503), PBDB3 (PB-503). |
Error code: | C-1333 |
Description: | Exhaust fan /2 (M81: PB-502, FM81: PB-503) drive abnormality. An error detection signal is detected continuously for specified time period while M81 is started or driving. 35-4 |
Causes: | Exhaust fan /2 (M81: PB-502, FM81: PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the connector connection and the wiring between PBDB/PBDB1 and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PB-502: 3-D PB-503: 3-D 3 Replace M81 (PB-502), FM81 (PB-503). - 4 Replace PBDB (PB-502), PBDB1 (PB-503). |
Error code: | C-1334 |
Description: | Pellet supply cooling fan motor (M4: PB-502, FM4: PB-503) rotation abnormality. An error detection signal is detected continuously for specified time period while M4 is started or driving. 35-4 |
Causes: | Pellet supply cooling fan motor (M4: PB-502, FM4: PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the connector connection and the wiring between PBDB/PBDB1 and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PB-502: 4-D PB-503: 4-D 3 Replace M4 (PB-502), FM4 (PB-503). - 4 Replace PBDB (PB-502), PBDB1 (PB-503). |
Error code: | C-1341 |
Description: | Stack assist fan /Fr (FM1) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM1 operation. |
Causes: | Stack assist fan /Fr (FM1: RU-506) RU control board (RUCB: RU-506) |
Remedy: | 1 Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. RU-506: 3-B 3 Replace FM1. - 4 Replace RUCB |
Error code: | C-1342 |
Description: | Stack assist fan /Rr (FM2) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM2 operation. |
Causes: | Stack assist fan /Rr (FM2: RU-506) RU control board (RUCB: RU-506) |
Remedy: | 1 Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. RU-506: 3-B 3 Replace FM2. - 4 Replace RUCB |
Error code: | C-1351 |
Description: | Error detection signals of FM/1, FM/2 and FM/3 are detected continuously for a specified period of time while the entrance paper fans /1 (FM1), /2 (FM2) and /3 (FM3) are ON. |
Causes: | • Entrance paper fan /1 (FM1) • Entrance paper fan /2 (FM2) • Entrance paper fan /3 (FM3) • RU control board (RUCB) |
Remedy: | 1. Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair or replace it if any abnormality. (Wiring diagram: RU-509: 8-F, 9-F) 3. Replace FM1, FM2 and FM3. 4. Replace RUCB |
Error code: | C-1352 |
Description: | Error detection signals of FM4 and FM5 are detected continuously for a specified period of time while the ventilation assist fans /1 (FM4) and /2 (FM5) are ON. |
Causes: | • Ventilation assist fan /1 (FM4) • Ventilation assist fan /2 (FM5) • RU control board (RUCB) |
Remedy: | 1. Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 9-F, 8-H) 3. Replace FM4 and FM5. 4. Replace RUCB |
Error code: | C-1353 |
Description: | Error detection signals of FM15, FM16 and FM17 are detected continuously for a specified period of time while the entrance paper fans /4 (FM15), /5 (FM16) and /6 (FM17) are ON. |
Causes: | • Entrance paper fan /4 (FM15) • Entrance paper fan /5 (FM16) • Entrance paper fan /6 (FM17) • RU control board (RUCB) |
Remedy: | 1. Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 17-L, 18-L) 3. Replace FM15, FM16 and FM17. 4. Replace RUCB |
Error code: | C-1354 |
Description: | Error detection signals of FM18, FM19 and FM20 are detected continuously for a specified period of time while the entrance paper fans /7 (FM18), /8 (FM19) and /9 (FM20) are ON. |
Causes: | • Entrance paper fan /7 (FM18) • Entrance paper fan /8 (FM19) • Entrance paper fan /9 (FM20) • RU control board (RUCB) |
Remedy: | 1. Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 18-L) 3. Replace FM18, FM19 and FM20. 4. Replace RUCB |
Error code: | C-1355 |
Description: | Error detection signals of FM21 is detected continuously for a specified period of time while the ventilation assist fan /3 (FM21) is ON. |
Causes: | • Jumper connector CN108 • Ventilation assist fan /3 (FM21) • RU control board (RUCB) |
Remedy: | 1. When HM-102 is not connected, check if the jumper connector CN108 is connected. Connect the connector if it is not connected. 2. Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 19-L) 4. Replace FM21. 5. Replace RUCB |
Error code: | C-1356 |
Description: | A specified period of time after the conveyance motor cooling fan (M10) is turned on, the EM signal of the M10 gets into an abnormal condition. |
Causes: | Confirmation of the wiring harness and the connector Conveyance motor cooling fan (M10) ZU control board (ZUCB) |
Remedy: | 1. Check the connector connection and the wiring between RUDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 19-O) 4. Replace FM6. 5. Replace RUDB. 6. Replace RUCB |
Error code: | C-1357 |
Description: | An error detection signal of FM7 is detected continuously for a specified period of time while the humidification section paper fan /2 (FM7) is ON. |
Causes: | • Humidification section paper fan /2 (FM7) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the connector connection and the wiring between RUDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 19-O) 4. Replace FM7. 5. Replace RUDB. 6. Replace RUCB |
Error code: | C-1358 |
Description: | An error detection signal of FM8 is detected continuously for a specified period of time while the humidification section paper fan /3 (FM8) is ON. |
Causes: | • Humidification section paper fan /3 (FM8) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the connector connection and the wiring between RUDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 19-O) 4. Replace FM8. 5. Replace RUDB. 6. Replace RUCB |
Error code: | C-1359 |
Description: | An error detection signal of FM9 is detected continuously for a specified period of time while the humidification section paper fan /4 (FM9) is ON. |
Causes: | • Humidification section paper fan /4 (FM9) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the connector connection and the wiring between RUDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 16-O) 4. Replace FM9. 5. Replace RUDB. 6. Replace RUCB |
Error code: | C-1360 |
Description: | An error detection signal of FM10 is detected continuously for a specified period of time while the humidification section paper fan /5 (FM10) is ON. |
Causes: | • Humidification section paper fan /5 (FM10) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the connector connection and the wiring between RUDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 17-O) 4. Replace FM10. 5. Replace RUDB. 6. Replace RUCB |
Error code: | C-1361 |
Description: | An error detection signal of FM11 is detected continuously for a specified period of time while the humidification section paper fan /6 (FM11) is ON. |
Causes: | • Humidification section paper fan /6 (FM11) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2 |
Remedy: | 1. Check the connector connection and the wiring between RUDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 17-O) 4. Replace FM11. 5. Replace RUDB. 6. Replace RUCB |
Error code: | C-1364 |
Description: | An error detection signal of FM14 is detected continuously for a specified period of time while the humidification section paper fan (FM14) is ON. |
Causes: | • Power supply fan (FM14) • DC power supply (DCPS) |
Remedy: | 1. Check the connector connection and the wiring between DCPS and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 6-I) 4. Replace FM14. 5. Replace DCPS. |
Error code: | C-1402 |
Description: | Non-volatile memory abnormality. |
Causes: | FNS control board (FNSCB: FS-521) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FNSCB, and repair it if any abnormality. - 3 Reinstalling FS firmware - 4 Replace FNSCB. |
Error code: | C-1403 |
Description: | FD non-volatile memory abnormality. |
Causes: | FD control board (FDCB: FD-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FDCB, and repair it if any abnormality. - 3 Reinstalling FD firmware - 4 Replace FDCB. |
Error code: | C-1404 |
Description: | SD non-volatile memory abnormality. |
Causes: | SD control board (SDCB: SD-506) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of SDCB, and repair it if any abnormality. - 3 Reinstalling SD firmware - 4 Replace SDCB. |
Error code: | C-1406 |
Description: | PB non-volatile memory abnormality. |
Causes: | PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB. |
Error code: | C-1407 |
Description: | Non-volatile memory abnormality. |
Causes: | RU control board (RUCB) |
Remedy: | 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB |
Error code: | C-1408 |
Description: | Non-volatile memory abnormality. |
Causes: | RU control board (RUCB: RU-510) |
Remedy: | 1. Turn OFF the sub power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB |
Error code: | C-1411 |
Description: | 5V power abnormality in the SD drive board (SDDB). |
Causes: | SD drive board (SDDB) SD control board (SDCB) |
Remedy: | 1 Check the connector connection and the wiring of SDDB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 3 Replace SDDB - 4 Replace SDCB. |
Error code: | C-1412 |
Description: | 24V activation failure |
Causes: | • Power source • FNS control board (FNSCB) |
Remedy: | 1. Confirm the connection from the main body to FS and if the power source is supplied. Modify if any abnormality. 2. Check FNSCB, and replace it if any abnormality. |
Error code: | C-1432 |
Description: | Communication error in FD |
Causes: | FD control board (FDCB: FD-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FDCB, and repair it if any abnormality. - 3 Reinstalling FD firmware - 4 Replace FDCB. |
Error code: | C-1433 |
Description: | Communication error in SD |
Causes: | SD control board (SDCB: SD-506) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of SDCB, and repair it if any abnormality. - 3 Reinstalling SD firmware - 4 Replace SDCB. |
Error code: | C-1435 |
Description: | PB control board (PBCB) error 1. Message queue full or the control abnormality of Sub CPU1 in PBCB. |
Causes: | PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB. |
Error code: | C-1436 |
Description: | PB control board (PBCB) error 2. Message queue full or the control abnormality of Sub CPU2 in PBCB. |
Causes: | PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB. |
Error code: | C-1437 |
Description: | PB control board (PBCB) error 3. Message queue of the communication among tasks in the PB is full. |
Causes: | PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB. |
Error code: | C-1438 |
Description: | Communication error in RU |
Causes: | Software bug |
Remedy: | 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB |
Error code: | C-1439 |
Description: | Communication error in RU |
Causes: | • Software bug |
Remedy: | 1. Turn OFF the sub power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB |
Error code: | C-1442 |
Description: | Communication error between FS-532 and SD-510. |
Causes: | • FNS control board (FNSCB) • SD control board (SDCB) DIPSW47-2 |
Remedy: | 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code. |
Error code: | C-1451 |
Description: | FD operation prohibition abnormality When the FD is unready, a signal to start operations is received from the main body. |
Causes: | FD control board (FDCB: FD-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FDCB, and repair it if any abnormality. - 3 Reinstalling FD firmware - 4 Replace FDCB. |
Error code: | C-1452 |
Description: | SD operation prohibition abnormality When the SD is unready, a signal to start operations is received from the main body. |
Causes: | SD control board (SDCB: SD-506) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of SDCB, and repair it if any abnormality. - 3 Reinstalling SD firmware - 4 Replace SDCB. |
Error code: | C-1454 |
Description: | PB operation prohibition abnormality When PB is unready, a signal to start operations is received from the main body. |
Causes: | PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB. |
Error code: | C-1455 |
Description: | When RU is unready, a signal to start operations is received from the main body. |
Causes: | Software bug |
Remedy: | 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB |
Error code: | C-1456 |
Description: | When RU is unready, a signal to start operations is received from the main body. |
Causes: | Software bug |
Remedy: | 1. Turn OFF the sub power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB |
Error code: | C-1499 |
Description: | Logical contradiction error |
Causes: | Software bug |
Remedy: | 1. Turn OFF the sub power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB |
Error code: | C-1501 |
Description: | Entrance conveyance motor (M1) drive abnormality. The entrance conveyance has not been completed within a specified period of time after M1 turns ON. 35-5 |
Causes: | Entrance conveyance motor (M1: PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the entrance conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 1-D PB-503: 1-D 5 Replace M1. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1502 |
Description: | Intermediate conveyance motor (M2) drive abnormality. An error detection signal is detected continuously for a specified time period while the M2 is driving. 35-4 |
Causes: | Intermediate conveyance motor (M2: PB-502, PB- 503) PB control board (PBCB: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the intermediate conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 2-D PB-503: 2-D 5 Replace M2. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1504 |
Description: | SC entrance conveyance motor (M11) drive abnormality. The SC entrance conveyance has not been completed within a specified period of time after M11 turns ON. 35-4 |
Causes: | SC entrance conveyance motor (M11: PB-502, PB- 503) PB control board (PBCB: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the SC entrance conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 4-D PB-503: 4-D 5 Replace M11. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1505 |
Description: | SC switchback conveyance motor (M12) drive abnormality. The switchback conveyance has not been completed within a specified period of time after M12 turns ON. 35-4 |
Causes: | SC switchback conveyance motor (M12: PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) |
Remedy: | 1 Check the SC switchback conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 4-D PB-503: 4-D 5 Replace M12. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1506 |
Description: | SC switchback release motor (M13) drive abnormality. The switchback roller release operation has not been completed within a specified period of time after M13 turns ON. 35-4 |
Causes: | SC switchback release motor (M13: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the SC switchback release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 6-D PB-503: 6-D 5 Replace M13. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1507 |
Description: | SC alignment motor (M15) drive abnormality. The SC alignment has not been completed within a specified period of time after M15 turns ON. 35-4 |
Causes: | SC alignment motor (M15: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the SC alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 5-D PB-503: 5-D 5 Replace M15. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. - |
Error code: | C-1508 |
Description: | SC bundle conveyance motor (M17) drive abnormality. The SC paper bundle conveyance has not been completed within a specified period of time after M17 turns ON. 35-4 |
Causes: | SC bundle conveyance motor (M17: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the SC bundle conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 5-D PB-503: 5-D 5 Replace M17. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1509 |
Description: | SC roller release motor (M18) drive abnormality. The SC roller release operation has not been completed within a specified period of time after M18 turns ON. 35-4 |
Causes: | SC roller release motor (M18: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the SC roller release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 6-D PB-503: 6-D 5 Replace M18. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1510 |
Description: | Clamp entrance movement motor (M19) drive abnormality. The movement of the SC entrance has not been completed within a specified period of time after M19 turns ON. 35-4 |
Causes: | Clamp entrance movement motor (M19: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the clamp entrance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 5-D PB-503: 5-D 5 Replace M19. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1511 |
Description: | Clamp entrance roller release motor (M20) drive abnormality. The SC entrance roller release operation has not been completed within a specified period of time after M20 turns ON. 35-4 |
Causes: | Clamp entrance roller release motor (M20: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the clamp entrance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 7-D PB-503: 7-D 5 Replace M20. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1512 |
Description: | Clamp alignment motor (M21) drive abnormality. The SC alignment has not been completed within a specified period of time after M21 turns ON. 35-4 |
Causes: | Clamp alignment motor (M21: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the clamp alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 7-D PB-503: 7-D 5 Replace M21. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1513 |
Description: | Clamp motor (M22) drive abnormality. The open/close process of the clamp section has not been completed within a specified period of time after M22 turns ON. 35-4 |
Causes: | Clamp motor (M22: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the clamp section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 8-D PB-503: 8-D 5 Replace M22. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1514 |
Description: | Clamp rotation motor (M23) drive abnormality. The rotation of the clamp section has not been completed within a specified period of time after M23 turns ON. 35-4 |
Causes: | Clamp rotation motor (M23: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the clamp section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 8-D PB-503: 8-D 5 Replace M23. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1515 |
Description: | Glue tank movement motor (M31) drive abnormality. The movement of the glue tank has not been completed within a specified period of time after M31 turns ON. 35-4 |
Causes: | Glue tank movement motor (M31: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank movement section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 8-D PB-503: 8-D 5 Replace M31. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1516 |
Description: | Glue apply roller motor (M32) drive abnormality. An error detection signal is detected continuously for a specified time period while the M32 is driving. 35-4 |
Causes: | Glue apply roller motor (M32: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the glue apply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 9-D PB-503: 9-D 5 Replace M32. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1517 |
Description: | PB-502: Abnormality of the glue supply. The count of a specified number of pellets, which is counted by the pellet count sensor (PS37), has not been reached after the pellet supply motor (M33) turns ON. The status was detected by a specified number of times in succession. PB-503: Abnormality of the glue supply. The supply operation which the pellet supply passage sensor (PS37) does not turn ON is detected twice in succession after turning ON the pellet supply pipe motor (M33). 35-4 |
Causes: | Pellet supply motor (M33: PB-502) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the pellet supply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 10-D PB-503: 10-D 5 Replace M33. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1518 |
Description: | Pellet supply arm motor (M34) drive abnormality. The movement of the pellet supply arm has not been completed within a specified period of time after M34 turns ON. 35-4 |
Causes: | Pellet supply arm motor (M34: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the pellet supply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 10-D PB-503: 10-D 5 Replace M34. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1519 |
Description: | Cover paper alignment motor (M41) drive abnormality. The alignment of the up/down cover paper has not been completed within a specified period of time after M41 turns ON. 35-4 |
Causes: | Cover paper alignment motor (M41: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 12-D PB-503: 12-D 5 Replace M41. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1520 |
Description: | Booklet exit motor (M42) drive abnormality. The booklet exit has not been completed within a specified period of time after M42 turns ON. 35-4 |
Causes: | Booklet exit motor (M42: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the booklet exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 12-D PB-503: 12-D 5 Replace M42. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1521 |
Description: | Cover paper conveyance arm motor /Rt (M43) drive abnormality. The driven arm /Rt shaking operation start has not been completed within a specified period of time after M43 turns ON. 35-4 |
Causes: | Cover paper conveyance arm motor /Rt (M43: PB- 502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 12-D PB-502: 12-D 5 Replace M43. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1522 |
Description: | Cover paper conveyance arm motor /Lt (M44) drive abnormality. The driven arm /Lt shaking operation start has not been completed within a specified period of time after M44 turns ON. 35-4 |
Causes: | Cover paper conveyance arm motor /Lt (M44: PB- 502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 13-D PB-502: 13-D 5 Replace M44. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1523 |
Description: | Cover paper conveyance motor (M45) drive abnormality. The cover paper conveyance start has not been completed within a specified period of time after M45 turns ON. 35-4 |
Causes: | Cover paper conveyance motor (M45: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 13-D PB-502: 13-D 5 Replace M45. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1524 |
Description: | Cover paper table up down motor /Fr (M46) drive abnormality. The cover paper table up or down movement has not been completed within a specified period of time after M46 turns ON. 35-4 |
Causes: | Cover paper table up down motor /Fr (M46: PB- 502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper table up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 11-D PB-502: 11-D 5 Replace M46. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. - |
Error code: | C-1525 |
Description: | Cover paper table up down motor /Rr (M47) drive abnormality. The cover paper table up or down movement has not been completed within a specified period of time after M47 turns ON. 35-4 |
Causes: | Cover paper table up down motor /Rr (M47: PB- 502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper table up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 11-D PB-503: 11-D 5 Replace M47. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1526 |
Description: | Cover paper folding motor /Rt (M48) drive abnormality. The movement of the cover paper folding plate /Rt has not been completed within a specified period of time after M48 turns ON. 35-4 |
Causes: | Cover paper folding motor /Rt (M48: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 14-D PB-503: 14-D 5 Replace M48. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1527 |
Description: | Cover paper folding motor /Lt (M49) drive abnormality. The movement of the cover paper folding plate /Lt has not been completed within a specified period of time after M49 turns ON. 35-4 |
Causes: | Cover paper folding motor /Lt (M49: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 14-D PB-503: 14-D 5 Replace M49. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1528 |
Description: | Cutter motor (M50) operation abnormality. The trimming of the cover paper has not been completed within a specified period of time after M50 turns ON. 35-4 |
Causes: | Cutter motor (M50: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the trimmer section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 14-D PB-503: 14-D 5 Replace M50. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1530 |
Description: | Booklet conveyance belt movement motor (M62) drive abnormality. The movement of the booklet conveyance section according to paper size has not been completed within a specified period of time after M62 turns ON. 35-4 |
Causes: | Booklet conveyance belt movement motor (M62: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the booklet conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 15-D PB-503: 15-D 5 Replace M62. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1531 |
Description: | The size changing operation of the carriage section has not been completed within a specified period of time after the booklet conveyance belt movement motor (M62) turns ON. |
Causes: | • PB control board (PBCB) • PB drive board (PBDB) • Booklet conveyance belt movement motor (M62) DIPSW7-6 |
Remedy: | 1. Check the booklet conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503: 15-D) 5. Replace M62. 6. Replace PBDB1. 7. Replace PBCB. |
Error code: | C-1532 |
Description: | Booklet conveyance belt up down motor (M63) drive abnormality. The up/down process of the booklet conveyance section has not been completed within a specified period of time after M63 turns ON. 35-4 |
Causes: | Booklet conveyance belt up down motor (M63: PB- 502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the booklet conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 16-D PB-503: 16-D 5 Replace M63. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1534 |
Description: | Booklet stopper motor (M65) drive abnormality. The pressing of the back edge of the booklet process has not been completed within a specified period of time after M65 turns ON. 35-4 |
Causes: | Booklet stopper motor (M65: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the booklet conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 16-D PB-503: 16-D 5 Replace M65. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1537 |
Description: | Cover paper tray lift motor (M73) drive abnormality. The tray moving up has not been completed within a specified period of time after M73 turns ON. 35-3 |
Causes: | Cover paper tray lift motor (M73: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper tray section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 19-D PB-503: 19-D 5 Replace M73. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1538 |
Description: | Cover paper feed motor (M74) drive abnormality. The paper feed operation has not been completed within a specified period of time after M74 turns ON. 35-3 |
Causes: | Cover paper feed motor (M74: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503) |
Remedy: | 1 Check the cover paper feed section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 17-D PB-503: 17-D 5 Replace M74. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. |
Error code: | C-1540 |
Description: | Low temperature abnormality of the center of the glue tank when warming up. After the warm-up is started, temperature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period. 35-5 |
Causes: | Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1541 |
Description: | Low temperature abnormality of the bottom of the glue tank when warming up. After the warm-up is started, temperature detected by the glue tank temperature sensor /Lw (TH4) has not risen to a prescribed level within a specified time period. 35-5 |
Causes: | Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1542 |
Description: | Glue apply roller temperature abnormality when warming up After the warm-up is started, temperature detected by the glue apply roller temperature sensor (TH1) has not risen to a prescribed level within a specified time period. 35-5 |
Causes: | Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1543 |
Description: | Temperature abnormality of the top of the glue tank after the pellet supply. After the pellet supply, temperature detected by the glue tank temperature sensor/Up (TH2) has not risen to a prescribed level within a specified time period. 35-5 |
Causes: | Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1544 |
Description: | Temperature abnormality of the center of the glue tank in the standby status During standby, after the glue tank heater (H1) is turned ON, temperature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period. 35-5 |
Causes: | Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1545 |
Description: | Temperature abnormality of the bottom of the glue tank after the glue tank heater (H1) turns ON When control temperature is reached, temperature detected by the glue tank temperature sensor/Lw (TH4) does not rise to a prescribed level within a specified time period after H1 turns ON. 35-5 |
Causes: | Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1546 |
Description: | Temperature abnormality of the glue apply roller after the glue tank heater (H1) turns ON When control temperature is reached, temperature detected by the glue apply roller temperature sensor (TH1) does not rise to a prescribed level within a specified time period after H1 turns ON. 35-5 |
Causes: | Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1547 |
Description: | Apply roller high temperature abnormality (software detection) The glue apply roller temperature sensor (TH1) detects an abnormal high temperature. 35-5 |
Causes: | Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1548 |
Description: | High temperature abnormality of the top of the glue tank (software detection) The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature. 35-5 |
Causes: | Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1549 |
Description: | High temperature abnormality of the center of the glue tank (software detection) The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature. 35-5 |
Causes: | Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1550 |
Description: | High temperature abnormality of the bottom of the glue tank (software detection) The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature. 35-5 |
Causes: | Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1551 |
Description: | Apply roller high temperature abnormality (hardware detection) The glue apply roller temperature sensor (TH1) detects an abnormal high temperature. 35-5 |
Causes: | Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1552 |
Description: | High temperature abnormality of the top of the glue tank (hardware detection) The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature. 35-5 |
Causes: | Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1553 |
Description: | High temperature abnormality of the center of the glue tank (hardware detection) The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature. 35-5 |
Causes: | Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1554 |
Description: | High temperature abnormality of the bottom of the glue tank (hardware detection) The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature. 35-5 |
Causes: | Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1555 |
Description: | Apply roller low temperature abnormality (software detection) The glue apply roller temperature sensor (TH1) detects an abnormal low temperature. 35-5 |
Causes: | Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1556 |
Description: | Low temperature abnormality of the top of the glue tank (software detection) The glue tank temperature sensor /Up (TH2) detects an abnormal low temperature. 35-5 |
Causes: | Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1557 |
Description: | Low temperature abnormality of the center of the glue tank (software detection) The glue tank temperature sensor /Md (TH3) detects an abnormal low temperature. 35-5 |
Causes: | Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1558 |
Description: | Low temperature abnormality of the bottom of the glue tank (software detection) The glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature. 35-5 |
Causes: | Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1559 |
Description: | Apply roller low temperature abnormality (hardware detection) The glue apply roller temperature sensor (TH1) detects an abnormal low temperature. 35-5 |
Causes: | Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1560 |
Description: | Low temperature abnormality of the top of the glue tank (hardware detection) The glue tank temperature sensor /Up (TH2) detects an abnormal low temperature. 35-5 |
Causes: | Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1561 |
Description: | Low temperature abnormality of the center of the glue tank (hardware detection) The glue tank temperature sensor /Md (TH3) detects an abnormal low temperature. 35-5 |
Causes: | Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1562 |
Description: | Low temperature abnormality of the bottom of the glue tank (hardware detection) The glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature. 35-5 |
Causes: | Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503) |
Remedy: | 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-1565 |
Description: | PB-503: Operation abnormality of the relay conveyance motor (M92) The relay conveyance does not start within the specified period of time after M92 turns ON. 35-4 |
Causes: | Intermediate conveyance motor (M92: PB-503) PB drive board /2 (PBDB2: PB-503) PB control board (PBCB: PB-503) |
Remedy: | 1 Check the relay conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB2 and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 23-V 4 Replace M92. - 5 Replace PBDB2. - 6 Replace PBCB. |
Error code: | C-1566 |
Description: | PB-503: Operation abnormality of the relay conveyance exit motor (M91) An error detection signal is detected continuously while the M91 is driving. 35-4 |
Causes: | Relay conveyance exit motor (M91: PB-503) PB control board (PBCB: PB-503) PB drive board /1 (PBDB1: PB-503) PB drive board /2 (PBDB2: PB-503) |
Remedy: | 1 Check the relay conveyance paper exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB2 and the motor, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 26-W 5 Replace M91. - 6 Replace PBDB2. - 7 Replace PBDB1. - 8 Replace PBCB. - |
Error code: | C-1567 |
Description: | PB-503: Operation abnormality of the pellet supply pipe motor (M33). The pellet supply pipe does not complete the operation within the specified period of time after M33 turns ON. 35-4 |
Causes: | Pellet supply pipe motor (M33: PB-503) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-503) |
Remedy: | 1 Check the pellet supply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB1 and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 10-D 4 Replace M33. - 5 Replace PBDB1. - 6 Replace PBCB. |
Error code: | C-1651 |
Description: | The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. |
Causes: | • Stacker tray up down motor (M1) • LS control board (LSCB) DIPSW6-6 |
Remedy: | 1. Check the stacker tray up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:LS-505:5-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram:LS-505:5-A) 5. Replace PS2. 6. Replace M1. 7. Replace LSCB. |
Error code: | C-1652 |
Description: | The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time. |
Causes: | • Shift unit motor (M5) • LS control board (LSCB) DIPSW6-6 |
Remedy: | 1. Check the shift unit section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 6-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-H) 5. Replace PS11. 6. Replace M5. 7. Replace LSCB. |
Error code: | C-1653 |
Description: | The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time. |
Causes: | • Alignment motor (M7) • LS control board (LSCB) DIPSW6-6 |
Remedy: | 1. Check the alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 7-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-H) 5. Replace PS12. 6. Replace M7. 7. Replace LSCB. |
Error code: | C-1654 |
Description: | The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON. |
Causes: | Grip conveyance motor (M4) DIPSW6-6 |
Remedy: | 1. Check the grip conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 6-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 2-H) 5. Replace PS5. 6. Replace M4. 7. Replace LSCB. |
Error code: | C-1655 |
Description: | The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. |
Causes: | • Stacker tray up down motor (M1) • Stacker tray upper limit switch (MS2) DIPSW6-6 |
Remedy: | 1. Check the stacker tray up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-A) 4. Check the operation of the switch, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 7-A) 5. Replace MS2. 6. Replace M1. 7. Replace LSCB. |
Error code: | C-1656 |
Description: | The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. |
Causes: | • Stacker tray up down motor (M1) • Stacker tray lower limit switch (MS3) DIPSW6-6 |
Remedy: | 1. Check the stacker tray up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-A) 4. Check the operation of the switch, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 7-A) 5. Replace MS3. 6. Replace M1. 7. Replace LSCB. |
Error code: | C-2101 |
Description: | When the charge cleaning home sensor (PS41) is OFF with the main power switch (SW1) ON, PS41 does not turn ON within a specified period of time after the charge cleaning motor (M23) turns ON for home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. PS41 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. It is checked that the time for the M23 operations is over. The charge cleaning limit sensor (PS42) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS41 being OFF. Or, PS41 does not turn ON within a specified period of time after PS42 turns ON. |
Causes: | Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 16-F 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 16-F 4 Replace PS26 or PS27. - 5 Replace M23. - 6 Replace PRCB. |
Error code: | C-2102 |
Description: | The blowout of ICP for the charge cleaning motor (M23) in the printer control board (PRCB) is checked. When the charge cleaning home sensor (PS41) is OFF with the main power switch (SW1) ON, PS41 does not turn ON within a specified period of time after the M23 turns ON for home position research operation (return operation). And at this time, an error detection signal (blowout of ICP) is detected. PS41 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. And at this time, an error detection signal (blowout of ICP) is detected. The charge cleaning limit sensor (PS42) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS41 being OFF. Or, PS41 does not turn ON within a specified period of time after PS42 turns ON. At this time, an error detection signal (blowout of ICP) is detected. |
Causes: | Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 16-F 3 Replace M23 and PRCB. |
Error code: | C-2103 |
Description: | The locking of the charge cleaning motor (M23) is detected. A motor lock signal is detected while moving from the charge cleaning limit sensor (PS42) side to the charge cleaning home sensor (PS41) side, and after a retry operation, a fifth motor lock signal is detected. |
Causes: | Confirming the operation of the charging corona cleaning member Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 16-F 3 Replace M23. - 4 Replace PRCB. |
Error code: | C-2201 |
Description: | The speed error signal of the toner bottle motor (M15) is checked. An error detection signal is detected twice in succession a specified period of time after M15 turns ON (the first signal is ignored). |
Causes: | Confirmation of the wiring harness and the connector Toner bottle motor (M15) Printer control board (PRCB) |
Remedy: | 1 Check the toner bottle installation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 3-M 4 Replace M6. - 5 Replace PRCB. |
Error code: | C-2202 |
Description: | The speed error signal of the developing motor (M3) is checked. Since an error detection signal is detected a second after M3 turns ON, turn OFF M3 for a specified period of time. Then, an error detection signal is detected again a specified period of time after it is turned ON again. |
Causes: | Confirmation of the wiring harness and the connector Developing motor (M3) Printer control board (PRCB) |
Remedy: | 1 Check the developing sleeve, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 18-K 4 Replace M3. - 5 Replace PRCB. |
Error code: | C-2203 |
Description: | The locking of the blade motor (M14) is detected. The error detection signal (over current) of M14 is detected. |
Causes: | Confirmation of the wiring harness and the connector Blade motor (M14) Printer control board (PRCB) |
Remedy: | 1 Check the trimmer blade operation, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 4 Replace M22. - 5 Replace PRCB. |
Error code: | C-2204 |
Description: | It is checked that the movement of the blade motor (M14) is not completed, and the 24V power source is also checked. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (24V cut out) is detected. |
Causes: | Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /1, and repair it if any abnormality. - 2 Replace PRCB. - 3 Replace DCPS /1. |
Error code: | C-2205 |
Description: | The blowout of ICP for the blade motor (M14) in the printer control board (PRCB) is checked. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, the error detection signal (blowout of ICP) of M14 is detected. |
Causes: | Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 20-K 3 Replace M2. - 4 Replace PRCB. |
Error code: | C-2206 |
Description: | It is checked that the movement of the blade motor (M14) is not completed. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal is not detected. |
Causes: | Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 20-K 3 Replace M2. - 4 Replace PRCB. |
Error code: | C-2207 |
Description: | It is checked that the movement of the blade motor (M14) is not completed, and 24V power source is also checked. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (24V cut out) is detected. |
Causes: | Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace PRCB. - 3 Replace DCPS /2. |
Error code: | C-2208 |
Description: | The blowout of ICP for the blade motor (M14) in the printer control board (PRCB) is checked. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, the error detection signal (blowout of ICP) of M14 is detected. |
Causes: | Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 3 Replace M22 and PRCB at a time. |
Error code: | C-2209 |
Description: | It is checked that the movement of the blade motor (M14) is not completed. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal is not detected. |
Causes: | Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the trimmer blade operation, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 4 Replace M22. - 5 Replace PRCB. |
Error code: | C-2210 |
Description: | It is checked that the drum motor (M2) does not start. The drum READY2 signal (READY signal) is not detected within a specified period of time after M2 turns ON. |
Causes: | Confirmation of the wiring harness and the connector Drum motor (M2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 20-K 3 Replace M2. - 4 Replace PRCB. |
Error code: | C-2211 |
Description: | The blowout of ICP for the toner supply motor (M11) in the printer control board (PRCB) is checked. An error detection signal (blowout of ICP) is detected when M11 turns ON. |
Causes: | Confirmation of the wiring harness and the connector Toner supply motor (M11) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 6-M 3 Replace M11 and PRCB at a time. |
Error code: | C-2212 |
Description: | Air separation motor (M10) power abnormality. An error detection signal (blowout of ICP) is detected when M10 turns ON. |
Causes: | Air separation motor (M10) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 5-M 3 Replace M10 and PRCB at a time. |
Error code: | C-2213 |
Description: | Air separation motor (M10) rotation abnormality. Since an error is detected when M10 turns ON, turn it OFF. An error is still detected when turn it ON again. |
Causes: | Air separation motor (M10) Printer control board (PRCB) |
Remedy: | 1 Check the air separation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 5-M 4 Replace M10. - 5 Replace PRCB. |
Error code: | C-2214 |
Description: | The toner conveyance abnormality is detected. When executing the toner supply operation for 8 minutes, the intermediate hopper toner remaining sensor (PS31) does not turn ON and the hopper toner remaining sensor /2 (PS33) detects ON in succession for 15 seconds. |
Causes: | Intermediate hopper toner remaining sensor (PS39) Hopper toner remaining sensor /2 (PS33) Printer control board (PRCB) |
Remedy: | 1 Check the hopper section and the intermediate hopper section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the sensor, and repair it if any abnormality. - 3 Check the sensor, and repair/replace it if any abnormality. 4-M 6-M 4 Replace PS39. - 5 Replace PS33. - 6 Replace PRCB. |
Error code: | C-2215 |
Description: | Hopper toner remaining sensor /2 (PS33) abnormality. When the toner is supplied for 8minutes, it is found that the toner remaining sensor /1 (PS32) does not turn ON and the PS33 turns OFF for the last 15seconds in succession. |
Causes: | Hopper toner remaining sensor /1 (PS32) Hopper toner remaining sensor /2 (PS33) Printer control board (PRCB) |
Remedy: | 1 Check the hopper section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the sensor, and repair it if any abnormality. - 3 Check the sensor, and repair/replace it if any abnormality. 4-M 4 Replace PS32. - 5 Replace PS33. - 6 Replace PRCB. |
Error code: | C-2217 |
Description: | Leakage at the mixing section is detected. When the toner pump motor (M28) is operating, the cup section toner remaining sensor (PS34) detects the toner being provided in succession for 20seconds. |
Causes: | Cup section toner remaining sensor (PS34) Toner pump motor (M28) Printer control board (PRCB) |
Remedy: | 1 Check the toner mixing section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check the sensor, and repair/replace it if any abnormality. 4-M 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 6-M 5 Replace PS34. - 6 Replace M28. - 7 Replace PRCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-2220 |
Description: | Toner pump motor (M28) rotation abnormality + 24V power abnormality. While M28 is rotating, an error detection signal (abnormal rotation/ 24V cut off) is detected for more than 1second. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Replace DCPS /2. - 4 Replace PRCB. |
Error code: | C-2221 |
Description: | When the recycle cut motor (M24) is turned ON, an error detection signal is detected twice in a row within a specified period of time. (An error detection signal on the first time is ignored.) |
Causes: | Confirmation of the wiring harness and the connector Recycle cut motor (M24) Recycle cut drive board (RCDB) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 6-M 3 Replace M28 and PRCB at a time. |
Error code: | C-2222 |
Description: | Toner pump motor (M28) rotation abnormality. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error detection signal (blowout of ICP/24V cut off) is not detected. |
Causes: | Toner pump motor (M28) Printer control board (PRCB) |
Remedy: | 1 Check the toner pump section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 6-M 4 Replace M28. - 5 Replace PRCB. |
Error code: | C-2224 |
Description: | Air pump motor (M29) rotation abnormality + 24V power abnormality. While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Replace DCPS /2. - 4 Replace PRCB. |
Error code: | C-2225 |
Description: | Air pump motor (M29) power abnormality. An error detection signal (abnormal rotation) is detected for more than 1second. At this time, an abnormality signal (blowout of ICP) is detected, but no abnormality signal (24V cut off) is detected. |
Causes: | Air pump motor (M29) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 6-M 3 Replace M29 and PRCB at a time. |
Error code: | C-2226 |
Description: | Air pump motor (M29) rotation abnormality. An error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected. |
Causes: | Air pump motor (M29) Printer control board (PRCB) |
Remedy: | 1 Check the air pump section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 6-M 4 Replace M29. - 5 Replace PRCB. |
Error code: | C-2227 |
Description: | Developing screw motor (M21) rotation abnormality. The M21EM error detection signal is detected twice in succession within a specified period of time after M21 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Developing screw motor (M21) Printer control board (PRCB) |
Remedy: | 1 Check the developing screw section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 18-K 4 Replace M21. - 5 Replace PRCB. |
Error code: | C-2228 |
Description: | The transfer belt motor (M30) rotation abnormality. The M30EM error detection signal is detected twice in succession within a specified period of time after M30 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
Causes: | Transfer belt motor (M30) ADU drive board (ADUDB) Printer control board (PRCB) |
Remedy: | 1 Check the transfer belt, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-O 5 Replace M30. - 6 Replace PRCB. - 7 Replace ADUDB. |
Error code: | C-2230 |
Description: | Waste toner box swing motor (M19) drive abnormality. The waste toner box swing sensor (PS15) ON or OFF is not detected twice in succession within a specified period of time after M19 turns ON. |
Causes: | Waste toner box swing sensor (PS15) Waste toner box swing motor (M19) Printer control board (PRCB) |
Remedy: | 1 Check the waste toner box swing section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 2-M 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 2-M 5 Replace PS15. - 6 Replace M19. - 7 Replace PRCB. |
Error code: | C-2231 |
Description: | De-curler motor (M32) rotation abnormality. The M32EM error detection signal is detected twice in succession within a specified period of time after M32 was turned ON, and the main door detection is Close. |
Causes: | De-curler motor (M32) ADU drive board (ADUDB) Printer control board (PRCB) |
Remedy: | 1 Check the de-curler section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-O 5 Replace M32. - 6 Replace PRCB. |
Error code: | C-2233 |
Description: | Waste toner box swing motor (M19) rotation abnormality. The M19EM error detection signal is not detected twice in succession within a specified period of time after M19 was turned ON. |
Causes: | Waste toner box swing motor (M19) Printer control board (PRCB) |
Remedy: | 1 Check the waste toner box swing section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 2-M 4 Replace M19. - 5 Replace PRCB. |
Error code: | C-2234 |
Description: | Transfer belt pressure release motor (M26) operation time abnormality 1. When M26 moves from the HP position to the pressure position, the transfer pressure position sensor /1 or /2 (PS55 or PS56) does not turn ON within a specified period of time. At this time, the main door detection is Close. |
Causes: | Transfer pressure position sensor /1 (PS55) Transfer pressure position sensor /2 (PS56) Transfer belt pressure release motor (M26) ADU drive board (ADUDB) |
Remedy: | 1 Check the transfer belt pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 19-L 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 21-L 5 Replace PS55 or PS56. - 6 Replace M26. - 7 Replace ADUDB. |
Error code: | C-2235 |
Description: | Transfer belt pressure release motor (M26) operation time abnormality 2. • The transfer pressure home sensor (PS54) ON is not detected within a specified period of time after the main power turns ON. At this time, the main door detection is Close. • When M26 moves from the pressure position to the HP position, PS54 does not turn ON within a specified period of time. At this time, the main door detection is Close. |
Causes: | Transfer pressure home sensor (PS54) Transfer belt pressure release motor (M26) ADU drive board (ADUDB) |
Remedy: | 1 Check the transfer belt pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 19-L 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 21-L 5 Replace PS54. - 6 Replace M26. - 7 Replace PRCB. |
Error code: | C-2236 |
Description: | Transfer belt pressure release motor (M26) power abnormality. While M26 is rotating, the M26EM error detection signal is detected. At this time, an error detection signal (blowout of ICP) is detected, and the main door detection is Close. |
Causes: | Transfer belt pressure release motor (M26) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 21-L 3 Replace M26 and ADUDB at a time. |
Error code: | C-2237 |
Description: | Waste toner motor (M9) rotation abnormality. The M9EM error detection signal is detected twice in succession within a specified period of time after M9 was turned ON. |
Causes: | Waste toner motor (M9) Printer control board (PRCB) |
Remedy: | 1 Check the waste toner section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 1-M 4 Replace M9. - 5 Replace PRCB. |
Error code: | C-2238 |
Description: | Blade motor (M22) abnormality. Waste blade motor does not move to the weak pressure position within a specified period of time after M22 turns ON. |
Causes: | • Blade sensor /1 (PS24) • Blade sensor /2 (PS25) • Blade motor (M22) • Printer control board (PRCB) |
Remedy: | 1. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 14-I) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 14-I, 15-I) 4. Replace PS24 or PS25. 5. Replace M22. 6. Replace PRCB. |
Error code: | C-2241 |
Description: | Abnormality of the intermediate hopper motor (M11) drive in the printer control board (PRCB). |
Causes: | • Intermediate hopper motor (M11) • Printer control board (PRCB) |
Remedy: | 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 2-P) 3. Replace M11 and PRCB at a time. |
Error code: | C-2242 |
Description: | Drum cleaner motor (M35) abnormality The M35 EM error detection signal is detected twice in succession within a specified period of time after M35 was turned ON. |
Causes: | • Drum cleaner motor (M35) • Printer control board (PRCB) |
Remedy: | 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Rotate the motor by I/O or hand, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 15-P) 3. Replace M35. 4. Replace PRCB. |
Error code: | C-2304 |
Description: | Transfer suction fan (FM5) rotation abnormality + 24V power abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-2306 |
Description: | Transfer suction fan (FM5) rotation abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected. |
Causes: | Transfer suction fan (FM5) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 3-L 3 Replace FM5. - 4 Replace PRCB. |
Error code: | C-2307 |
Description: | Developing cooling fan /Up (FM31) rotation abnormality + 24V power abnormality. The FM31EM error detection signal is detected twice in succession within a specified period of time after FM31 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-2309 |
Description: | Developing cooling fan (FM31) rotation abnormality. The FMx error detection signal is detected twice in succession within a specified period of time after FMx was turned ON. However, error detection signals V cut off/blowout of ICP) are not detected. |
Causes: | Developing cooling fan (FM31) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 3 Replace FM31. - 4 Replace PRCB. |
Error code: | C-2311 |
Description: | Developing cooling fan (FM11) rotation abnormality + 24V power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-2313 |
Description: | Pump cooling fan (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected. |
Causes: | Pump cooling fan (FM11) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 3-L 4 Replace FM11. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-2317 |
Description: | Charger exhaust fan (FM44) rotation abnormality + 24V power abnormality. The FM44 EM error detection signal is detected twice in succession within a specified period of time after FM44 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | • DC power supply /2 (DCPS/2) • AC drive board (ACDB) |
Remedy: | 1. Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. 2. Replace DCPS /2 3. Replace ACDB. |
Error code: | C-2318 |
Description: | Charger exhaust fan (FM44) rotation abnormality. The FM44 EM error detection signal is detected twice in succession within a specified period of time after FM44 was turned ON. However, error detection signal (24V cut off) is not detected. |
Causes: | • Charger exhaust fan (FM44) • Printer control board (PRCB) • AC drive board (ACDB) |
Remedy: | 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between ACDB and the fan, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 13-A) 4. Replace FM44. 5. Replace PRCB. 6. Replace ACDB. |
Error code: | C-2401 |
Description: | The temperature of the drum temperature sensor (TH5) detected a specified period of time after the main power switch (SW1) is turned ON is -3°C or lower, and also, the drum temperature after a specified period of time is -3°C or lower. |
Causes: | Confirmation of the wiring harness and the connector Drum temperature sensor (TH5) Printer control board (PRCB) |
Remedy: | 1 Check the EL section, and clean/repair it if any abnormality. 16-F 2 Check the connector connection and the wiring between PRCB and EL, and repair it if any abnormality. - 3 Replace EL. - 4 Replace PRCB. |
Error code: | C-2402 |
Description: | When the main power switch (SW1) turns ON with the fusing temperature below 50°C, the detected temperature of the drum temperature sensor (TH5) is more than 52°C, and when the detected temperature is above 52°C after a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Drum temperature sensor (TH5) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and TH5, and repair it if any abnormality. - 2 Check the TH5, and repair/replace it if any abnormality. 17-F 3 Replace TH5. - 4 Replace PRCB. |
Error code: | C-2403 |
Description: | The erase lamp (EL1) is unconnected. |
Causes: | Confirmation of the wiring harness and the connector Erase lamp (EL1) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and TH5, and repair it if any abnormality. - 2 Check the TH5, and repair/replace it if any abnormality. 17-F 3 Replace TH5. - 4 Replace PRCB. |
Error code: | C-2411 |
Description: | TCR sensor (TCRS) output abnormality 1. The TCRS output is detected more than 3.0V (153step) in printing. |
Causes: | TCR sensor (TCRS) Printer control board (PRCB) |
Remedy: | 1 Check TCRS, and clean/repair it if there is sensor dirt or any abnormality. 18-F 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 4 Replace TCRS. - 5 Replace PRCB. |
Error code: | C-2412 |
Description: | TCR sensor (TCRS) output abnormality 2. The TCRS output is detected more than 0.5V (25step) in printing. |
Causes: | TCR sensor (TCRS) Printer control board (PRCB) |
Remedy: | 1 Check TCRS, and clean/repair it if there is sensor dirt or any abnormality. 18-F 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 4 Replace TCRS. - 5 Replace PRCB. |
Error code: | C-2413 |
Description: | TCR sensor (TCRS) output abnormality 3. • The mode does not return from the toner supply mode to the normal mode within a specified period of time after the toner automatic supply is executed in printing. • The TCRS output is detected more than 2.6V (132step). |
Causes: | TCR sensor (TCRS) Printer control board (PRCB) |
Remedy: | 1 Check TCRS, and clean/repair it if there is sensor dirt or any abnormality. 18-F 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 4 Replace TCRS. - 5 Replace PRCB. |
Error code: | C-2701 |
Description: | A charge leak is detected. After a charge error detection signal is detected while in the charge ON, up to 5 charge ON/OFF operations occur in succession. |
Causes: | Confirmation of the charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /1 (HV1) Printer control board (PRCB) |
Remedy: | 1 Clean the power feed section for the charger. - 2 Check the charger (charging wire and the grid), and clean/repair it if there is any dirt or abnormality. - 3 Check the connector connection and the wiring between HV1 and the charger, and repair it if any abnormality. 18-G 4 Replace HV1. |
Error code: | C-2702 |
Description: | A transfer leak is detected. After a transfer error detection signal is detected while in the transfer ON, up to 5 transfer ON/OFF operations occur in succession. |
Causes: | Confirmation of the transfer/ separation charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) Printer control board (PRCB) ADU drive board (ADUDB) |
Remedy: | 1 Check the transfer roller section, and clean/repair it if there is sensor dirt or any abnormality. - 2 Clean the power feed section for the transfer roller. - 3 Check the transfer roller pressure section, and clean/repair it if there is sensor dirt or any abnormality. - 4 Check the connector connection and the wiring between HV2 and the power feed section, and repair it if any abnormality. 13-O 5 Replace HV2. |
Error code: | C-2704 |
Description: | The error detection signal (blowout of a 24V ICP) of the high voltage unit /2 (HV2) is detected. |
Causes: | Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and MFDBS/ MFDBR, and repair/replace it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB and HV2, and repair/replace it if any abnormality. - 3 Replace ADUDB and HV2 at a time. |
Error code: | C-2705 |
Description: | PCC leak is detected. After a PCC EM signal abnormality is detected while in the PCC ON, up to 5 transfer ON/OFF operations occur in succession while in 10 prints. |
Causes: | PCC unit High voltage unit /3 (HV3) |
Remedy: | 1 Check the discharging wire of the PCC unit and replace it if the wire is cut. - 2 Check the installation condition of the PCC unit and install it again if any abnormality. - 3 Check the connector connection and the wiring between HV3 and the power feed section, and repair/replace it if any abnormality. 18-F 4 Replace HV3. |
Error code: | C-2801 |
Description: | The dirt correction of the sensor is not completed. While in the maximum density correction, the dirt correction of the IDC sensor is not sufficient. When this condition is detected 10 times in succession, the error code is displayed. |
Causes: | Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Printer control board (PRCB) |
Remedy: | 1 Check TCB, and clean it with alcohol if there is IDC sensor dirt or any abnormality. Be sure to clean TCB with alcohol, otherwise replacement of TCB is required. 17-F 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCB, and repair it if any abnormality. - 4 Replace TCB. - 5 Replace PRCB. |
Error code: | C-2802 |
Description: | The maximum density correction (Dmax) is not completed. While in Dmax, the number of rotations of the developing sleeve gets to the maximum. |
Causes: | Developing motor (M3) Toner control board (TCB) Printer control board (PRCB) |
Remedy: | 1 Check TCB, and clean it with alcohol if there is IDC sensor dirt or any abnormality. Be sure to clean TCB with alcohol, otherwise replacement of TCB is required. 17-F 2 Check the connector connection and the wiring between PRCB and TCB, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and clean/repair/ replace it if any abnormality. 18-K 4 Replace TCB. - 5 Replace M3. - 6 Replace PRCB. |
Error code: | C-2803 |
Description: | The IDC sensor (TCB) output abnormality. While in the maximum density correction, a patch for control is not output. (No output is made from the gamma sensor.) |
Causes: | Toner control board (TCB) LPH board (LPHB) Overall control board (OACB) Image processing board (IPB) |
Remedy: | 1 Check TCB, and clean it with alcohol if there is IDC sensor dirt or any abnormality. Be sure to clean TCB with alcohol, otherwise replacement of TCB is required. 17-F 2 Check the LPH section, and clean/replace it if there is LED dirt or any abnormality. 18-C 3 Check the connector connection and the wiring between OACB and IPB, and repair it if any abnormality. - 4 Check the connector connection and the wiring between LPHB and IPB, and repair it if any abnormality. - 5 Replace LPHB. - 6 Replace IPB. - 7 Replace OACB. |
Error code: | C-2804 |
Description: | The dirt correction of the IDC sensor is not completed |
Causes: | Toner control board (TCB) Printer control board (PRCB) |
Remedy: | 1 Check TCB, and clean it with alcohol if there is IDC sensor dirt or any abnormality. Be sure to clean TCB with alcohol, otherwise replacement of TCB is required. 17-F 2 Check the developing section, and clean/repair it if there is any dirt or abnormality. - 3 Check the connector connection and the wiring between PRCB and TCB, and repair it if any abnormality. - 4 Replace TCB. - 5 Replace PRCB. |
Error code: | C-2807 |
Description: | Drum potential sensor (DPS) output abnormality 1. The DPS detects the value less than the potential specified value of the unexposed part 5 times in succession. |
Causes: | Drum potential sensor (DPS) Drum potential sensor board (DPSB) Printer control board (PRCB) |
Remedy: | 1 Check DPS, and clean/repair it if there is sensor dirt or any abnormality. 17-F 2 Check the connector connection and the wiring between PRCB and DPS, and repair it if any abnormality. - 3 Replace DPS. - 4 Replace DPSB. - 5 Replace PRCB. |
Error code: | C-2808 |
Description: | Dot diameter correction abnormality. While in the dot diameter correction, the correction is terminated with an abnormal value. |
Causes: | Drum potential sensor (DPS) Drum potential sensor board (DPSB) Image processing board (IPB) Printer control board (PRCB) Overall control board (OACB) |
Remedy: | 1 Check DPS, and clean/repair it if there is sensor dirt or any abnormality. 17-F 2 Check the connector connection and the wiring between PRCB and OACB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between OACB and IPB, and repair it if any abnormality. - 4 Replace DPS. - 5 Replace DPSB. - 6 Replace IPB. - 7 Replace PRCB. |
Error code: | C-2809 |
Description: | Drum potential sensor (DPS) output abnormality 2. While in the 0V check of the DPS, more than 100V of the drum surface potential is detected more than 5 times. When this condition is detected 5 times in succession, the error code is displayed. |
Causes: | Drum potential sensor (DPS) Drum potential sensor board (DPSB) Printer control board (PRCB) |
Remedy: | 1 Check DPS, and clean/repair it if there is sensor dirt or any abnormality. 17-F 2 Check the connector connection and the wiring between PRCB and DPS, and repair it if any abnormality. - 3 Replace DPS. - 4 Replace DPSB. - 5 Replace PRCB. |
Error code: | C-2810 |
Description: | Drum potential sensor (DPS) output abnormality. While in the drum potential correction, a patch for control is not output with the V1 getting to more than 350V. When this condition is detected 5 times in succession, the error code is displayed. |
Causes: | Confirmation of the wiring harness and the connector Drum potential sensor board (DPSB) Drum potential sensor (DPS) Printer control board (PRCB) |
Remedy: | 1 Check DPS, and clean/repair it if there is sensor dirt or any abnormality. 17-F 2 Check the connector connection and the wiring between PRCB and DPS, and repair it if any abnormality. - 3 Replace DPS. - 4 Replace DPSB. - 5 Replace PRCB. |
Error code: | C-2811 |
Description: | The data is defective. While in the drum potential correction, no convergence is obtained even after correction is made more than 10 times. When this condition is detected 5 times in succession, the error code is displayed. |
Causes: | Confirmation of the wiring harness and the connector Drum potential sensor board (DPSB) Drum potential sensor (DPS) Printer control board (PRCB) |
Remedy: | 1 Check DPS, and clean/repair it if there is sensor dirt or any abnormality. 17-F 2 Check the connector connection and the wiring between PRCB and DPS, and repair it if any abnormality. - 3 Replace DPS. - 4 Replace DPSB. - 5 Replace PRCB. |
Error code: | C-2812 |
Description: | Transfer current auto adjustment abnormality. The auto adjustment of the transfer current has not completed. |
Causes: | Transfer roller High voltage unit /2 (HV2) |
Remedy: | 1 Check the transfer roller section, and clean/repair it if there is sensor dirt or any abnormality. - 2 Clean the power feed section for the transfer roller. - 3 Check the connector connection and the wiring between HV2 and the power feed section, and repair it if any abnormality. 13-O 4 Replace HV2. |
Error code: | C-2815 |
Description: | Developing bias auto adjustment abnormality. The auto adjustment of the developing bias has not completed. |
Causes: | Developer High voltage unit /1 (HV1) |
Remedy: | 1 Clean the power feed section for the developing sleeve. - 2 Check the developer, and clean/repair it if there is any adhesion or abnormality. - 3 Check the connector connection and the wiring between HV1 and the developing sleeve, and repair it if any abnormality. 18-G 4 Replace HV1. |
Error code: | C-2816 |
Description: | Drum charger capacity deterioration. When the charger grid/developing bias is in excess of the limit of correction, lower the developing potential/fogging margin potential in steps of 50V. As a result, less than 50V of the difference with the target charger potential is detected 10 times in succession. |
Causes: | Drum potential sensor (DPS) Drum potential sensor board (DPSB) Charging corona High voltage unit /1 (HV1) |
Remedy: | 1 Clean the power feed section for the charger. - 2 Check DPS, and clean/repair it if there is sensor dirt or any abnormality. 17-F 3 Check the charger (charging wire and the grid), and clean/repair it if there is any dirt or abnormality. - 4 Check the drum, and clean/repair it if there is any dirt or abnormality. - 5 Check the connector connection and the wiring between HV1 and the charger, and repair it if any abnormality. 18-G 6 Replace DPS. - 7 Replace DPSB. - 8 Replace the drum. - 9 Replace HV1. |
Error code: | C-2821 |
Description: | The toner supply prohibition status is not released 1. Even though the TCR sensor (TCRS) output increases, the number of the toner supply prohibition status continuity is detected 30 times, and more than 2.5V of the TCRS output value is detected. |
Causes: | Developing unit TCR sensor (TCRS) Printer control board (PRCB) |
Remedy: | 1 Check the developing section, and clean/repair it if there is any dirt or abnormality. - 2 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 3 Replacing the developing unit - 4 Replace PRCB. |
Error code: | C-2822 |
Description: | The toner supply prohibition status is not released 2. The number of the toner supply prohibition status continuity becomes 100 times. |
Causes: | Developing unit TCR sensor (TCRS) Printer control board (PRCB) |
Remedy: | 1 Check the developing section, and clean/repair it if there is any dirt or abnormality. - 2 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 3 Replacing the developing unit - 4 Replace PRCB. |
Error code: | C-3102 |
Description: | The blowout of ICP for the web motor (M16) in the printer control board (PRCB) is checked. When M16 turns ON from OFF, the blowout of ICP abnormality is detected with a 24V down signal normal. |
Causes: | Confirmation of the wiring harness and the connector Web motor (M16) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the fusing pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 13-F 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 5 Replace PS58. - 6 Replace M33. - 7 Replace PRCB. |
Error code: | C-3103 |
Description: | Fusing pressure release motor (M33) operation time abnormality 2. The fusing pressure home sensor (PS58) ON is not detected within a specified period of time after the main power turns ON. When M33 moves from the pressure position to the release position, PS58 does not turn ON within a specified period of time. |
Causes: | Fusing pressure home sensor (PS58) Fusing pressure release motor (M33) Printer control board (PRCB) |
Remedy: | 1 Check the fusing pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 13-F 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 5 Replace PS58. - 6 Replace M33. - 7 Replace PRCB. |
Error code: | C-3104 |
Description: | Abnormality when the fusing unit used exclusively for PRESS1250/1250P/1052 or EF-120 is set to PRO 951. An error is detected in the following conditions with the fusing unit used exclusively for PRESS1250/1250P/1052 or EF-102 is set to PRO 951. In case that either of the fusing pressure home sensor (PS58), fusing pressure position sensor /1 (PS59), fusing pressure position sensor /2 (PS60) and fusing pressure position sensor /3 (PS61) turns ON when both the ADU knob set and the fusing unit set are detected. |
Causes: | • Fusing unit • Printer control board (PRCB) |
Remedy: | 1. Check that the proper fusing unit is installed, and replace it if the wrong one is installed 2. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality 3. Replace PRCB. |
Error code: | C-3201 |
Description: | Drum motor (M24) power abnormality + 24V power abnormality. When M24 turns ON, error detection signals (blowout of ICP and the 24V cut off) are detected. |
Causes: | DC power supply /2 (DCPS /2) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-3202 |
Description: | Web motor (M24) power abnormality. An error detection signal (blowout of ICP) is detected when M24 turns ON. At this time, an error detection signal (24V cut off) is not detected. |
Causes: | Web motor (M24) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 3 Replace M24 and ACDB at a time. |
Error code: | C-3501 |
Description: | Fusing roller /Up high temperature detection (software). TH1 detects a temperature of 235°C or above 5 times in a specified period of time. Or, the fusing temperature sensor /2 (TH2) detects a temperature of 240°C or above. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3502 |
Description: | Fusing heating roller high temperature abnormality (software). TH3 detects a temperature of 230°C or above 5 times in a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3503 |
Description: | Fusing roller /Up high temperature abnormality (hardware). An abnormal condition is detected with the fusing error detection signal 1. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3504 |
Description: | Fusing heating roller high temperature abnormality (hardware). An abnormal condition is detected with the fusing error detection signal 4. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3801 |
Description: | Fusing roller /Up low temperature abnormality (software). TH1 does not get to 75°C when a specified period of time has elapsed after the main switch (SW1) is turned ON for the fusing ON control. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3802 |
Description: | Fusing heating roller low temperature abnormality (software). TH3 does not get to 50°C when a specified period of time has elapsed after the main switch (SW1) is turned ON for the fusing ON control. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3901 |
Description: | Fusing roller /Up sensor abnormality (software). TH1 detects a temperature of 230°C or above 30 times in a row in a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3902 |
Description: | Fusing heating roller sensor abnormality (software). TH3 detects a temperature of 220°C or above 30 times in a row in a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3903 |
Description: | Fusing roller /Up sensor abnormality (hardware). The output voltage of the TH1 is detected as a low temperature abnormality (- 6°C or lower) in the comparator circuit. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3904 |
Description: | Fusing heating roller sensor abnormality (hardware). The output voltage of the TH3 is detected as a low temperature abnormality (-6°C or lower) in the comparator circuit. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3905 |
Description: | Fusing roller /Up abnormality detection (hardware). The output voltage of the TH2 is detected as a low temperature (-6°C or lower) or high temperature (240.5°C or higher) abnormality in the comparator circuit. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 2 (TH2) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-3906 |
Description: | Fusing heating roller abnormality detection (hardware). The output voltage of the TH4 is detected as a low temperature (-6°C or lower) or high temperature (240.5°C or higher) abnormality in the comparator circuit. |
Causes: | Confirmation of the wiring harness and the connector Fusing temperature sensor / 4 (TH4) Fusing heater lamp / 3 (L3) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire. |
Error code: | C-4301 |
Description: | The rotation of the write unit cooling fan /1 (FM5) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. |
Causes: | Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-4303 |
Description: | The rotation of the write unit cooling fan /1 (FM5) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected. |
Causes: | Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM12. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-4304 |
Description: | When the print is started, an error detection signal of the writing section cooling fan /1 (FM5) is detected. |
Causes: | Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM12. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-4305 |
Description: | The rotation of the write unit cooling fan /2 (FM8) is checked and the 24V power source is also checked. An abnormal condition occurs with the FM8 EM signal a specified period of time after the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. |
Causes: | Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-4307 |
Description: | The rotation of the write unit cooling fan /2 (FM8) is checked. An abnormal condition occurs with the FM8 EM signal a specified period of time after the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected. |
Causes: | Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 4 Replace FM3 - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-4314 |
Description: | The rotation of the polygon cooling fan (FM9) is checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after FM9 turns ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected. |
Causes: | Confirmation of the wiring harness and the connector Polygon cooling fan (FM9) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-4316 |
Description: | Front cooling fan (FM18) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected. |
Causes: | Front cooling fan (FM18) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM18. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-4701 |
Description: | FIFO address abnormality for the printer. While in the image write, the expansion processing of image data that is read in is not correctly terminated. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) Gate array damaged |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Replace IPB. |
Error code: | C-4702 |
Description: | An error interrupt occurs with the compression/expansion chip FIFO. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) Gate array damaged |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Replace IPB. |
Error code: | C-4703 |
Description: | Elongation abnormality. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) Gate array damaged |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Check DIMM to see that it is properly set. 21-D 3 Replace DIMM. - 4 Replace IPB. |
Error code: | C-4705 |
Description: | While in the image write, the expansion processing from the memory to the printer does not terminate within a specified period of time. The output from the page memory to the printer does not terminate within a specified period of time. The PVV is not detected within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Check the connector connection and the wiring on PRCB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between IPB and PRCB, and repair it if any abnormality. - 4 Replace IPB. - 5 Replace PRCB. |
Error code: | C-4706 |
Description: | When writing images, in spite of no resource provided, an inappropriate processing such as an access to the elongation device is made. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Rewrite the firmware for image control. - 3 Replace IPB. |
Error code: | C-4708 |
Description: | When accessing to the memory device, a defective software is detected. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Rewrite the firmware for image control. - 3 Replace IPB. |
Error code: | C-4709 |
Description: | The expansion processing from the memory to the page memory is not terminated within a specified period of time. The compression processing from the page memory to the memory is not terminated within a specified period of time. The development from the memory into the page memory is not terminated within a specified period of time. The transmission of the compressed data from memory to memory is not terminated within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring on IPB and OACB, and repair it if any abnormality. - 2 Check the connector connection and the wiring on PRCB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between IPB and OACB/between OACB and PRCB, and repair it if any abnormality. - 4 Rewrite the firmware for image control. - 5 Replace IPB. - 6 Replace OACB. - 7 Replace PRCB. |
Error code: | C-4720 |
Description: | Shift amount abnormality while in the repeat. When the shift amount (used for cutting margin, etc.) while in the repeat is negative (-). |
Causes: | Image processing board (IPB) |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Rewrite the firmware for image control. - 3 Replace IPB. |
Error code: | C-4721 |
Description: | The centering adjustment is too late. The print operation starts before the paper centering adjustment is terminated. (The centering adjustment is too late.) |
Causes: | Original skew sensor /Fr (PS65) Original skew sensor /Rr (PS66) Printer control board (PRCB) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring on IPB and PECB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUCB and the sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 18-L 4 Replace PS65 or PS66. - 5 Replace PRCB. - 6 Replace ADUDB. |
Error code: | C-4722 |
Description: | The creation of the PWM gamma curve failed. A PWM gamma curve is not created properly. |
Causes: | Toner control board (TCB) Printer control board (PRCB) |
Remedy: | 1 Check TCB, and clean it with alcohol if there is IDC sensor dirt or any abnormality. Be sure to clean TCB with alcohol, otherwise replacement of TCB is required. - 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCB, and repair it if any abnormality. - 4 Replace TCB. - 5 Replace PRCB. |
Error code: | C-4725 |
Description: | LPH drive board (LPHB) connection abnormality. Due to the disconnection of the LPHB connector, no connection is available with the overall control board. |
Causes: | LPH board (LPHB) Relay board /A (RBA) Image processing board (IPB) |
Remedy: | 1 Check the connector connection and the wiring between LPHB and RBA, and repair it if any abnormality. - 2 Check the connector connection and the wiring between IPB and RBA, and repair it if any abnormality. - 3 Check LPHB, and repair/replace it if any abnormality. 18-C 4 Rewrite the firmware for image control. - 5 Replace LPHB. - 6 Replace RBA. - 7 Replace IPB. |
Error code: | C-4850 |
Description: | Segmentation abnormality. The overall control software accesses an illegal address. |
Causes: | Image processing board (IPB) |
Remedy: | 1 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 2 Rewrite the firmware for image control. - 3 Replace IPB. |
Error code: | C-5010 |
Description: | Communication error between the overall control board (OACB) and the printer control board (PRCB). Any of the following error is detected during data reception between OACB and PRCB. • Data head error • Data check sum error • Undefined command reception error • Occurrence of communication GA error vector |
Causes: | Printer control board (PRCB) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on OACB, and repair it if any abnormality. - 3 Check the connector connection and the wiring on PRCB, and repair it if any abnormality. - 4 Check the connector connection and the wiring between OACB and PRCB, and repair it if any abnormality. - 5 Replace OACB. - 6 Replace PRCB. |
Error code: | C-5101 |
Description: | A speed error signal of the fusing motor (M1) is checked. An error detection signal is detected twice in succession a specified period of time after M1 turns ON. (The first signal is ignored.) |
Causes: | Confirmation of the wiring harness and the connector Fusing motor (M1) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the fusing drive section, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 17-K 4 Replace M1. - 5 Replace PRCB. |
Error code: | C-5102 |
Description: | Toner counter (CNT1) power abnormality 1. When CNT1 is turned ON from OFF, an error detection signal (blowout of ICP/24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-5311 |
Description: | When the print is started, an error detection signal of the cooling fan /3 (FM6) is detected. |
Causes: | Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-5313 |
Description: | Rotation of the ADU cooling fan / 1 (FM10) is checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after FM10 is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected. |
Causes: | Confirmation of the wiring harness and the connector ADU cooling fan /1 (FM10) ADU drive board (ADUDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM6. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-5317 |
Description: | Rotation of the ADU cooling fan / 4 (FM23) is checked. An abnormal condition occurs with the FM23 EM signal a specified period of time after FM23 is turned ON. This abnormal condition recurs even a specified period of time after FM23 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected. |
Causes: | Confirmation of the wiring harness and the connector ADU cooling fan /4 (FM23) ADU drive board (ADUDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-5319 |
Description: | Rotation of the ADU cooling fan / 5 (FM25) is checked. An abnormal condition occurs with the FM25 EM signal a specified period of time after FM25 is turned ON. This abnormal condition recurs even a specified period of time after FM25 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected. |
Causes: | Confirmation of the wiring harness and the connector ADU cooling fan /5 (FM25) ADU drive board (ADUDB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 4 Replace FM1. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-5320 |
Description: | An abnormal condition occurs with the FM18 EM signal a specified period of time after the cooling fan /5 (FM18) is turned ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected. |
Causes: | Confirmation of the wiring harness and the connector Cooling fan /5 (FM18) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-5322 |
Description: | Rotation of the cooling fan /5 (FM18) is checked. An abnormal condition occurs with the FM18 EM signal a specified period of time after FM18 is turned ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected. |
Causes: | Confirmation of the wiring harness and the connector Cooling fan /5 (FM18) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 4 Replace FM2. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-5326 |
Description: | Cooling fan /1 (FM1) rotation abnormality. When the print is started, the EM signal of FM1 turns ON. |
Causes: | Cooling fan /1 (FM1) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 4 Replace FM1. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-5327 |
Description: | Cooling fan /2 (FM2) rotation abnormality 2. When the print is started, the EM signal of FM2 turns ON. |
Causes: | Cooling fan /2 (FM2) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 4 Replace FM2. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-5328 |
Description: | Suction cooling fan /1 (FM6) rotation abnormality 2. When the print is started, the EM signal of FM6 turns ON. |
Causes: | Suction cooling fan /1 (FM6) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM6. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-5329 |
Description: | Abnormality of the fun connected to ADU drive board. The EM error detection signal is detected twice in succession within a specified period of time after ADU cooling fan /1 (FM14), /2 (FM15), /3 (FM13), sensor cooling fan /1 (FM16) and registration cooling fan (FM17) connected to ADU drive board was turned ON. At this time, the door close detection of the door open/close sensor /1 (PS1), /2 (PS2) and PF door open/close sensor (PS70) is detected 10 times in succession. |
Causes: | ADU cooling fan /1 (FM14) ADU cooling fan /2 (FM15) ADU cooling fan /3 (FM13) Sensor cooling fan (FM16) Registration cooling fan (FM17) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. - 3 Replace the fan. - 4 Replace ADUDB. |
Error code: | C-5330 |
Description: | The rotation of the power supply cooling fan /3 (FM32) is checked. An abnormal condition occurs with the FM32 EM signal a specified period of time after FM32 is turned ON. This abnormal condition recurs even a specified period of time after FM32 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected. |
Causes: | Confirmation of the wiring harness and the connector Power supply cooling fan /3 (FM32) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-5332 |
Description: | Suction cooling fan /2 (FM7) rotation abnormality. The EM error detection signal of FM7 is detected twice in succession within a specified period of time after FM7 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected. |
Causes: | Suction cooling fan /2 (FM7) Printer control board (PRCB) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM7. - 5 Replace PRCB. - 6 Replace ACDB. |
Error code: | C-5337 |
Description: | De-curler fan /1 (FM29) rotation abnormality. The EM error detection signal of FM29 is detected twice in succession within a specified period of time after FM29 was turned ON. At this time, the door close is detected. |
Causes: | de-curler fan /1 (FM29) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 17-O 3 Replace FM29. - 4 Replace ADUDB. - |
Error code: | C-5338 |
Description: | De-curler fan /2 (FM30) rotation abnormality. The EM error detection signal of FM30 is detected twice in succession within a specified period of time after FM30 was turned ON. At this time, the door close is detected. |
Causes: | De-curler fan /2 (FM30) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 18-O 3 Replace FM30. - 4 Replace ADUDB. |
Error code: | C-5339 |
Description: | Transfer belt cleaning fan (FM27) rotation abnormality. When the print is started, the EM signal of FM27 turns ON. |
Causes: | Transfer belt cleaning fan (FM27) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. - 3 Replace FM27. - 4 Replace ADUDB. |
Error code: | C-5340 |
Description: | Rotation abnormality of fans equipped in ADU. The EM error signal is detected twice in succession within a specified period of time after ADU cooling fun /2 (FM15), belt cooling fan (FM37) and reverse cooling fan (FM38) was turned ON. At this time, the door close is detected. |
Causes: | ADU cooling fan /2 (FM15) Belt cooling fan (FM37) Reverse cooling fan (FM38) ADU drive board (ADUDB) |
Remedy: | 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 17-O, 20-O, 21-O 3 Replace FM15. - 3 Replace FM37. - 3 Replace FM38. - 4 Replace ADUDB. |
Error code: | C-5341 |
Description: | Collection pipe cooling fan (FM34) rotation abnormality + 24V power abnormality. The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB. |
Error code: | C-5343 |
Description: | Collection pipe cooling fan (FM34) rotation abnormality 1. The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected. |
Causes: | Collection pipe cooling fan (FM34) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 3 Replace FM34. - 4 Replace PRCB. |
Error code: | C-5344 |
Description: | Collection pipe cooling fan (FM34) rotation abnormality 2. When the print is started, the EM signal of FM34 turns ON. |
Causes: | Collection pipe cooling fan (FM34) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 3 Replace FM34. - 4 Replace PRCB. |
Error code: | C-5345 |
Description: | Toner bottle cooling fan (FM35) rotation abnormality + 24V power abnormality. The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
Causes: | DC power supply /2 (DCPS /2) AC drive board (ACDB) |
Remedy: | 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB. |
Error code: | C-5347 |
Description: | Toner bottle cooling fan (FM35) rotation abnormality 1. The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected. |
Causes: | Toner bottle cooling fan (FM35) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM35. - 4 Replace PRCB. |
Error code: | C-5348 |
Description: | Toner bottle cooling fan (FM35) rotation abnormality 2. When the print is started, the EM signal of FM35 turns ON. |
Causes: | Toner bottle cooling fan (FM35) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM35. - 4 Replace PRCB. |
Error code: | C-6101 |
Description: | The scanner home sensor (PS5) does not turn ON within a specified period of time after the home position search is started. |
Causes: | Confirmation of the wiring harness and the connector Scanner motor (M13) Scanner home sensor (PS5) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | Check the connector connection and the wiring between SDB and DCPS /1, and repair it if any abnormality. - 2 Replace DCPS /1. - 3 Replace SDB. |
Error code: | C-6102 |
Description: | Scanner motor (M27) power abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected. |
Causes: | Scanner motor (M27) Scanner drive board (SDB) |
Remedy: | 1 Check the connector connection and the wiring between SDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 1-F 3 Replace M27 and SDB at a time. |
Error code: | C-6103 |
Description: | Scanner motor (M27) movement time abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (blowout of a fuse/24V cut off) of M27 is not detected. |
Causes: | Scanner home sensor (PS51) APS sensor /1 (PS52) Scanner motor (M27) Scanner drive board (SDB) |
Remedy: | 1 Check the scanner drive section, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 2-F 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 1-F 5 Replace PS51 and PS52. - 6 Replace M27. - 7 Replace SDB. |
Error code: | C-6301 |
Description: | The rotation of the scanner cooling fan (FM7) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM7 EM signal a specified period of time after FM7 turns ON. This abnormal condition recurs even a specified period of time after FM7 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. |
Causes: | Confirmation of the wiring harness and the connector Scanner cooling fan (FM7) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2) |
Remedy: | 1 Check the connector connection and the wiring between SDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace SDB. |
Error code: | C-6302 |
Description: | Scanner cooling fan (FM19) power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected. |
Causes: | Scanner cooling fan (FM19) Scanner drive board (SDB) |
Remedy: | 1 Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-F 3 Replace FM19 and SDB. |
Error code: | C-6303 |
Description: | Scanner cooling fan (FM19) rotation abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected. |
Causes: | Scanner cooling fan (FM19) Scanner drive board (SDB) Printer control board (PRCB) |
Remedy: | 1 Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDB and PRCB, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-F 4 Replace FM19. - 5 Replace SDB. - 6 Replace PRCB. |
Error code: | C-6701 |
Description: | When processing images, a filter coefficient cannot be created normally. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6702 |
Description: | FIFO address abnormality for the scanner. While in the image read, the compression of image data that is read in is not correctly terminated. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6703 |
Description: | After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6704 |
Description: | While in the image read, the compression processing from the scanner into the memory does not terminate within a specified period of time. The development from the scanner into the page memory does not terminate within a specified period of time. The SVV is not detected within a specified period of time. |
Causes: | Confirming the DF operation Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between IPB and OACB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between OACB and PRCB, and repair it if any abnormality. - 4 Replace IPB. - 5 Replace OACB. - 6 Replace PRCB. |
Error code: | C-6705 |
Description: | When reading images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6706 |
Description: | While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6707 |
Description: | Shading correction abnormality (GA abnormality). |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6708 |
Description: | AOC/AGC adjustment abnormality. The light blocking cover at the read section and the lens cover are removed. • The connector of the CCD board is disconnected. • The power cable of the CCD board is unplugged. • The ICP of the CCD board is cut off. The light volume of the exposure lamp is excessive. The exposure lamp does not light up. |
Causes: | 1. CCD related parts Confirmation of the wiring harness and the connector CCD board (CCDB) Overall control board (OACB) 2. Exposure lamp related parts Confirmation of the wiring harness and the connector Exposure lamp (L4) L4 inverter (L4INVB) Scanner drive board (SDB) |
Remedy: | 1 Check the reading section, and repair it if any abnormality such as cover off. - 2 Check the connector connection and the wiring between IPB and CCDB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDB and L4_INVB/ between L4_INVB and L4, and repair it if any abnormality. 2-F 4 When L4 is high-light intensity, low-light intensity or does not light, replace L4. - 5 When L4 is high-light intensity, low-light intensity or does not light after replacing L4, replace L4_INVB. - 6 Replace CCDB. - |
Error code: | C-6709 |
Description: | Abnormality of the adjustment data by resolutions. The adjustment data evacuated by resolutions is not available. |
Causes: | Image processing board (IPB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6710 |
Description: | Density conversion gamma curve creation abnormality. A density conversion gamma curve cannot be created normally. |
Causes: | Image processing board (IPB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6717 |
Description: | Sequentially shot page area abnormality. Due to an image area abnormality on the memory, images cannot be developed on the memory. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB. |
Error code: | C-6719 |
Description: | The scan operation starts before the original skew adjustment is terminated. (The skew adjustment is too late.) |
Causes: | Confirming the DF operation Confirmation of the wiring harness and the connector Original skew sensor /Rr (PS311: DF) Original skew sensor /Rr (PS312: DF) Overall control board (OACB) |
Remedy: | 1 Check the original skew sensor, and repair it if any abnormality. DF-615: 2-G 2 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between IDFCB and OACB, and repair it if any abnormality. - 4 Conduct the DF paper skew adjustment of the mechanical adjustment to correct the original skew. - 5 Conduct [Service mode]-[Process adjustment]-[ADF Skew Offset Adj.] - 6 Replace PS311 or PS312. - 7 Replace DFCB - 8 Replace OACB. |
Error code: | C-6721 |
Description: | The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs. |
Causes: | Confirmation of the wiring harness and the connector Exposure lamp (L4) L4 inverter (L4INVB) Scanner drive board (SDB) |
Remedy: | 1 Check the reading section, and repair it if any abnormality such as cover off. - 2 Check the connector connection and the wiring between IPB and CCDB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDB and L4_INVB/ between L4_INVB and L4, and repair it if any abnormality. 2-F 4 When L4 is high-light intensity, low-light intensity or does not light, replace L4. - 5 When L4 is high-light intensity, low-light intensity or does not light after replacing L4, replace L4_INVB. - 6 Replace CCDB. - |
Error code: | C-6801 |
Description: | A communication error between OACB and OB1 is checked. |
Causes: | Confirmation of the wiring harness and the connector Operation board /1 (OB1) Operation board /3 (OB3) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between OB1 and OACB, and repair it if any abnormality. - 3 Check the connector connection and the wiring of the operation panel, and repair it if any abnormality. - 4 Replace OACB. - 5 Replace OB1. |
Error code: | C-8001 |
Description: | Although the main body sends out data according to the data retransmission request made by the DF, a retransmission request signal is received again. |
Causes: | Confirmation of the wiring harness and the connector DF control board (DFCB: DF) Overall control board (OACB: main body) |
Remedy: | 1 Check the connector connection and the wiring between IDFCB and OACB, and repair it if any abnormality. - 2 Replace DFCB - 3 Replace OACB. |
Error code: | C-8002 |
Description: | When a checksum error or an SRGA reception error was detected while in the reception in serial communication, a signal was sent to make a request for sending data again. And when data is being received upon this request, a checksum error or an SRGA reception error is detected again. |
Causes: | Confirmation of the wiring harness and the connector DF control board (DFCB: DF) Overall control board (OACB: main body) |
Remedy: | 1 Check the connector connection and the wiring between IDFCB and OACB, and repair it if any abnormality. - 2 Replace DFCB - 3 Replace OACB. |
Error code: | C-8003 |
Description: | When the main power switch (SW1) is ON, there is no response to the initial communication request from the main body to the DF even after a specified period of time elapses. |
Causes: | Confirmation of the wiring harness and the connector DF control board (DFCB) |
Remedy: | 1 Check the connector connection and the wiring between IDFCB and OACB, and repair it if any abnormality. - 2 Replace DFCB - 3 Replace OACB. |
Error code: | C-8201 |
Description: | Tray up/down motor (M303) abnormality. |
Causes: | Confirmation of the wiring harness and the connector Confirmation of the original tray up/down drive parts Tray up/down motor (M303) DF control board (DFCB) |
Remedy: | Check the original tray up/down section, and repair it if any abnormality. - 2 Check the connector connection and the wiring between DFCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. DF-615: 6-E 4 Replace M303. - 5 Replace DFCB |
Error code: | C-8301 |
Description: | Cooling fan (FM301) abnormality. |
Causes: | Confirmation of the wiring harness and the connector Cooling fan (FM301) DF control board (DFCB) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. DF-615: 7-C, 8-G 3 Replace FM301 or FM302. - 4 Replace DFCB |
Error code: | C-8401 |
Description: | Original registration sensor (PS306) abnormality. |
Causes: | Confirming the sensor operation Confirmation of the wiring harness and the connector Original registration sensor (PS306) DF control board (DFCB) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 2-E, 2-D 3 Replace PS306 or PS318. - 4 Replace DFCB |
Error code: | C-8402 |
Description: | Original conveyance sensor (PS308) abnormality. |
Causes: | Confirming the sensor operation Confirmation of the wiring harness and the connector Original conveyance sensor (PS308) DF control board (DFCB) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 2-G 3 Replace PS308. - 4 Replace DFCB |
Error code: | C-8403 |
Description: | Original reverse sensor (PS309) abnormality. |
Causes: | Confirming the sensor operation Confirmation of the wiring harness and the connector Original reverse sensor (PS309) DF control board (DFCB) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 3-F 3 Replace PS309. - 4 Replace DFCB |
Error code: | C-8404 |
Description: | Non-volatile memory error. |
Causes: | Confirmation of the wiring harness and the connector DF control board (DFCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on DFCB, and repair it if any abnormality. - 3 Rewrite the firmware of DF-615. - 4 Replace DFCB |
Error code: | C-8405 |
Description: | Reverse jam sensor (PS304) abnormality. |
Causes: | Confirming the sensor operation Confirmation of the wiring harness and the connector Reverse jam sensor (PS304) DF control board (DFCB) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 3-E 3 Replace PS304. - 4 Replace DFCB |
Error code: | C-8406 |
Description: | Original reverse/exit sensor (PS313) abnormality. |
Causes: | Confirming the sensor operation Confirmation of the wiring harness and the connector Original reverse/exit sensor (PS313) DF control board (DFCB) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 4-B 3 Replace PS313. - 4 Replace DFCB |
Error code: | C-8407 |
Description: | Original skew sensor /Fr (PS312) abnormality. 18-4 |
Causes: | Original skew sensor /Fr (PS312: DF-615) DF control board (DFCB: DF-615) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 2-G 3 Replace PS312. - 4 Replace DFCB |
Error code: | C-8408 |
Description: | Original skew sensor /Rr (PS311) abnormality. 18-4 |
Causes: | Original skew sensor /Rr (PS311: DF-615) DF control board (DFCB: DF-615) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 2-G 3 Replace PS311. - 4 Replace DFCB |
Error code: | C-8409 |
Description: | Original registration sensor /Lt (PS306) abnormality. 18-4 |
Causes: | Original registration sensor /Lt (PS306: DF-615) DF control board (DFCB: DF-615) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. DF-615: 2-E 3 Replace PS306. - 4 Replace DFCB |
Error code: | C-8410 |
Description: | Centering sensor /Fr (PS320) abnormality. 18-4 |
Causes: | Centering LED sensor /Fr (PS319: DF-615) Centering sensor /Fr (PS320: DF-615) DF control board (DFCB: DF-615) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check the sensor to see LED emission and light-receiving path, and repair/replace it if any abnormality. DF-615: 1-H, 2-H 3 Replace PS319 and PS320. - 4 Replace DFCB |
Error code: | C-8411 |
Description: | Centering sensor /Rr (PS321) abnormality. 18-4 |
Causes: | Centering LED sensor /Rr (PS322: DF-615) Centering sensor/Rr (PS321: DF-615) DF control board (DFCB: DF-615) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 2 Check the sensor to see LED emission and light-receiving path, and repair/replace it if any abnormality. DF-615: 2-H, 2-I 3 Replace PS321 and PS322. - 4 Replace DFCB |
Error code: | C-8412 |
Description: | Multi feed detection sensor (MFDBS, MFDBR) abnormality. 18-4 |
Causes: | Multi feed detection board /S (MFDBS: DF-615) Multi feed detection board /R (MFDBR: DF-615) DF control board (DFCB: DF-615) |
Remedy: | 1 Check the connector connection and the wiring between DFCB and the multi feed detection board, and repair it if any abnormality. - 2 Check the multi feed detection board to see light-emission and light-receiving path, and repair/replace it if any abnormality. DF-615: 3-C, 7-A 3 Replace MFDBS or MFDBR. - 4 Replace DFCB |
Error code: | C-A001 |
Description: | DMA abnormality. |
Remedy: | 1 Check the connector connection and the wiring between ICB and PCIRB/between PCIRB and OACB, and repair it if any abnormality. - 2 Replace ICB. - 3 Replace PCIRB. - 4 Replace OACB. |
Error code: | C-A002 |
Description: | HDD/2 (HDD2) abnormality. |
Causes: | Confirmation of the wiring harness and the connector HDD/2 (HDD2) PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 Check the connector connection and the wiring between ICB and HDD2/between PCIRB and HDD2, and repair it if any abnormality. - 2 Format HDD2. - 3 Replace HDD2. - 4 Replace PCIRB. - 5 Replace ICB. |
Error code: | C-A003 |
Description: | IC cooling fan (FM28) abnormality. |
Causes: | Confirmation of the wiring harness and the connector IC cooling fan (FM28) PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 Check the connector connection and the wiring between ICB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 22-D 3 Replace FM24. - 4 Replace ICB. |
Error code: | C-A004 |
Description: | FATAL error. |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on ICB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ICB and PCIRB/between PCIRB and OACB, and repair it if any abnormality. - 4 Replace ICB. |
Error code: | C-A005 |
Description: | The CF card in ICB is different from the program version of the HDD/2 (HDD2). |
Causes: | Reinstalling IC firmware IC board (ICB) |
Remedy: | 1 Check the firmware versions of CF and HDD2 and rewrite if the versions are improper. - 2 Replace CF. - 3 Replace HDD2. |
Error code: | C-A006 |
Description: | While in the security ON, the unlock of the HDD/2 (HDD2) results in failure. (Due to the mismatch of the password) |
Causes: | Confirmation of the wiring harness and the connector HDD/2 (HDD2) IC board (ICB) |
Remedy: | 1 Check to see that HDD2 password for the security mode is properly set, and repair it if any abnormality. |
Error code: | C-A007 |
Description: | While in the security ON, an unlocked HDD is connected. |
Causes: | Confirmation of the wiring harness and the connector HDD/2 (HDD2) IC board (ICB) |
Remedy: | 1 Check to see that HDD2 password for the security mode is properly set, and repair it if any abnormality. |
Error code: | C-A008 |
Description: | An unformatted HDD/2 (HDD2) is detected. |
Causes: | Confirmation of the wiring harness and the connector Hard disk format HDD/2 (HDD2) |
Remedy: | 1 Format HDD2. - 2 Replace HDD2. |
Error code: | C-A009 |
Description: | Controller memory abnormality. |
Causes: | DIMM (DIMM) IC board (ICB) |
Remedy: | 1 Check DIMM on ICB, and reinstall it if any abnormality. 21-D 2 Replace DIMM. - 3 Replace ICB. |
Error code: | C-A101 |
Description: | The communication from ICB to the overall control board (OACB) is blocked. |
Causes: | Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 Check the connector connection and the wiring between ICB and PCIRB/between PCIRB and OACB, and repair it if any abnormality. - 2 Replace ICB. - 3 Replace PCIRB. - 4 Replace OACB. |
Error code: | C-C101 |
Description: | Initial communication error between OACB/PRCB. When the main power switch (SW1) is turned ON, a response from the printer control board (PRCB) is not received even after a specified period of time elapses. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and OACB, and repair it if any abnormality. - 3 Replace PRCB. - 4 Replace OACB. |
Error code: | C-C102 |
Description: | Communication error between OACB/PRCB. |
Causes: | Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and OACB, and repair it if any abnormality. - 3 Replace PRCB. - 4 Replace OACB. |
Error code: | C-C103 |
Description: | Communication error between OACB/OB1. |
Causes: | Confirmation of the wiring harness and the connector Operation board /1 (OB1) Operation board /3 (OB3) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between OB1 and OACB, and repair it if any abnormality. 9-C 3 Check the connector connection and the wiring of the operation panel, and repair it if any abnormality. - 4 Replace OB1. - 5 Replace OACB. |
Error code: | C-C104 |
Description: | When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the printer control program. |
Causes: | S and CA program |
Remedy: | 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and PRCB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace PRCB. |
Error code: | C-C105 |
Description: | ISW write abnormality 2 of the printer control board. |
Causes: | IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) Printer control board (PRCB) |
Remedy: | 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and PRCB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace PRCB. |
Error code: | C-C106 |
Description: | While in the data transmission by the ISW, a formal header information cannot be received within a specified period of time. |
Causes: | USB cable USB port on PC |
Remedy: | 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace OACB. |
Error code: | C-C107 |
Description: | While in the data transmission by the ISW, a checksum error or header error is detected with the download data. |
Causes: | USB cable Program file corruption |
Remedy: | 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace OACB. |
Error code: | C-C108 |
Description: | When ISW transfers data, the data is not written into the flash ROM correctly. |
Causes: | USB cable The board to which the data is transferred. |
Remedy: | 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace OACB. |
Error code: | C-C109 |
Description: | When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the FS control program. |
Causes: | FS control program |
Remedy: | 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB. |
Error code: | C-C111 |
Description: | ISW write abnormality on the 1st tandem LS. The firmware is not written on first LS or an error is detected during the ROM check. |
Causes: | IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) |
Remedy: | 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB. |
Error code: | C-C112 |
Description: | ISW write abnormality on the 2nd tandem LS. The firmware is not written on second LS or an error is detected during the ROM check. |
Causes: | IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) |
Remedy: | 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB. |
Error code: | C-C113 |
Description: | ISW write abnormality on FD. The firmware is not written on FD or an error is detected during the ROM check. |
Causes: | IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) |
Remedy: | 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB. |
Error code: | C-C114 |
Description: | ISW write abnormality on SD. The firmware is not written on SD or an error is detected during the ROM check. or an error is detected during the ROM check. |
Causes: | IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) |
Remedy: | 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB. |
Error code: | C-C116 |
Description: | ISW write abnormality on PB. The firmware is not written on PB or an error is detected during the ROM check. |
Causes: | IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) |
Remedy: | 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB. |
Error code: | C-C117 |
Description: | When turning the sub power switch (SW2) ON, ISW unwritten area in the GP program was detected. |
Causes: | GP control firmware |
Remedy: | 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB. |
Error code: | C-C118 |
Description: | When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU firmware. |
Causes: | • Firmware of RUCB • RU control board (RUCB) |
Remedy: | 1. Reinstall the RUCB firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RBU and OACB, and repair it if any abnormality. 5. Replace RUCB |
Error code: | C-C119 |
Description: | When turning the sub power switch (SW2) ON, ISW unwritten area in the MK program was detected. |
Causes: | I/F board (IFB) |
Remedy: | 1. Reinstall the RU firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RUB and OACB, and repair it if any abnormality. 5. Replace RUCB |
Error code: | C-C120 |
Description: | When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the DF control program. |
Causes: | Confirmation of the wiring harness and the connector DF control board (DFCB: DF) Overall control board (OACB: main body) |
Remedy: | 1 Check the connector connection and the wiring between the main body and DF, and repair it if any abnormality. - 2 Reinstalling DF firmware - 3 Replace DFCB - 4 Replace OACB. |
Error code: | C-C121 |
Description: | When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (3rd tandem). |
Causes: | • LSCB firmware • LS control board (LSCB) |
Remedy: | 1. Reinstall the LSCB firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RBU and OACB, and repair it if any abnormality. 5. Replace LSCB. |
Error code: | C-C124 |
Description: | When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the SD firmware. |
Causes: | • Firmware of SD • SD control board (SDCB) |
Remedy: | 1. Reinstalling SDCB firmware 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RBU and OACB, and repair it if any abnormality. 5. Replace SDCB. |
Error code: | C-C125 |
Description: | When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the IC program. |
Causes: | IC program |
Remedy: | 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Reinstall the firmware related to the controller. - 3 Replace ICB. |
Error code: | C-C130 |
Description: | Wrong firmware. A firmware for different type is installed. |
Remedy: | 1 Reinstall the correct firmware |
Error code: | C-C131 |
Description: | DF-615 is installed to PRO 951. Or, DF-615 is installed to PRESS1250/1052. |
Causes: | DF |
Remedy: | 1. Check DF, and repair it if any abnormality. |
Error code: | C-C132 |
Description: | The image processing board (IPB) used exclusively for PRESS1250/1250P/1052 is installed to PRO951. Or, IPB used exclusively for PRO951 is installed to PRESS1250/1250P/1052. |
Causes: | Image processing board (IPB) |
Remedy: | 1. Check that the proper IPB is installed, and replace it if the wrong one is installed. 2. Check the connector and the wiring connected to IPB, and repair it if any abnormality. 3. Replace IPB. |
Error code: | C-C136 |
Description: | When the version differs between Common API for the overall control and IC controller. |
Causes: | • Overall control board (OACB) • IC board (ICB) |
Remedy: | 1. Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 2. Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. (Wiring diagram: Main body (4/4): 21-D, Main body (1/4): 11-N) 3. Reinstall the firmware of the image control (I1) and the IC controler (P). 4. Replace ICB or OACB. |
Error code: | C-D001 |
Description: | HDD/1 (HDD1) initialization abnormality. The HDD1 is defective, or the connector is poorly connected. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB) |
Remedy: | 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. - 2 Format HDD1. - 3 Replace HDD1. |
Error code: | C-D002 |
Description: | The JOB information cannot be stored on the HDD/1 (HDD1). |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. 4-D 2 Reinstall the firmware related to the overall control. - 3 Replace HDD1. |
Error code: | C-D003 |
Description: | When HDD/1 (HDD1) JOB auto deletion is being executed, a route cannot be opened. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. 4-D 2 Reinstall the firmware related to the overall control. - 3 Replace HDD1. |
Error code: | C-D004 |
Description: | HDD/1 (HDD1) access defective. The HDD1 is defective, or the connector is poorly connected. |
Causes: | Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. 4-D 2 Reinstall the firmware related to the overall control. - 3 Replace HDD1. |
Error code: | C-D010 |
Description: | HDD overwrite erase is conducted. |
Remedy: | 1 Format HDD1. - 2 Replace HDD1. |
Error code: | C-D080 |
Description: | The common API related HDD file on the hard disk / 1 (HDD1) is crushed |
Causes: | Hard disk /1 (HDD1) |
Remedy: | 1. Execute output check code "99-03" in I/O check mode. 2. Replace HDD1. |
Error code: | C-E001 |
Description: | The message queue is insufficient or destroyed. |
Causes: | Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB. |
Error code: | C-E002 |
Description: | The parameter value is in excess of the permissible limits. |
Causes: | Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB. |
Error code: | C-E003 |
Description: | The ID of the task that sends the message queue is undefined. |
Causes: | Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB. |
Error code: | C-E004 |
Description: | The receiving event of the message is undefined. |
Causes: | Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB. |
Error code: | C-E005 |
Description: | Memory access abnormality. |
Causes: | Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB. |
Error code: | C-E006 |
Description: | Header readout address abnormality. |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB. |
Error code: | C-E007 |
Description: | DIMM memory abnormality. An error is detected in the DIMM memory check at the start. |
Causes: | Overall control board (OACB) |
Remedy: | 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB. |
Название
Konica Minolta TN015 Тонер-картридж черный
Konica Minolta Сервисный комплект
Konica Minolta Блок проявки