Kyocera ECOSYS M6026cdn
Рейтинг
Модули
Paper Feed Section 1
Electrical Components 1
Developer Section
PAPER CASSETTE
DRIVE SECTION
FRAME L
PANEL
(Электронные компоненты)
SCANNER SECTION
DUPLEX
COVERS
Image Formation Section
Document Processor
Paper Conveying Section
CASSETTE ASSEMBLY
FAX Section
ELECTRICAL COMPONENTS 2
Laser Scanner Section
TRANSFER SECTION
PAPER FEED
Fuser Section
PAPER FEED SECTION 2
Operation Section
Детали Laser Scanner Section
Деталь: | PARTS HOLDER FEED ASSY SP |
Парткод: | 302KV94191 |
Деталь: | PARTS HOLDER MIDDLE ROLLER ASSY SP |
Парткод: | 302KV94200 |
Деталь: | PARTS PWB ASSY CASSETTE SP |
Парткод: | 302KT94070 |
Деталь: | ACTUATOR PE |
Парткод: | 302KT06050 |
Деталь: | ACTUATOR REGIST |
Парткод: | 302KV06090 |
Деталь: | ACTUATOR B |
Парткод: | 302KV06341 |
Деталь: | PARTS HOLDER RETARD ASSY SP |
Парткод: | 302KT94051 |
Цена: | 2 700 ₽ |
Деталь: | GUIDE CASSETTE |
Парткод: | 302KT06011 |
Деталь: | FRAME FEED |
Парткод: | 302KV06012 |
Деталь: | GUIDE PICK HOLDER |
Парткод: | 302KV06031 |
Деталь: | SHAFT FEED |
Парткод: | 302KV06151 |
Деталь: | RELEASE ACTUATOR PE |
Парткод: | 302KV06180 |
Деталь: | SPRING ACTUATOR A |
Парткод: | 302KV06350 |
Деталь: | PIN FEED |
Парткод: | 302KV06370 |
Деталь: | COVER RETARD |
Парткод: | 302KV06610 |
Деталь: | CONN.CORD ASSY S03586 |
Парткод: | 302KV46450 |
Деталь: | SPRING ACT |
Парткод: | 302KV06201 |
Деталь: | PARTS PWB ENGINE ASSY SP |
Парткод: | 302M894061 |
Деталь: | PARTS PWB ENGINE ASSY SP |
Парткод: | 302PV94030 |
Деталь: | PARTS ID SENSOR ASSY SP |
Парткод: | 302KV94320 |
Цена: | 6 700 ₽ |
Деталь: | PARTS PWB ASSY RFID SP |
Парткод: | 302KV94350 |
Цена: | 110 ₽ |
Деталь: | PARTS PWB ASSY THERMISTOR SP |
Парткод: | 302KV94360 |
Цена: | 6 100 ₽ |
Деталь: | PARTS BUSH GEAR SP |
Парткод: | 302KV94080 |
Деталь: | PARTS MOTOR-DC ASSY K SP |
Парткод: | 302KV94300 |
Цена: | 6 300 ₽ |
Деталь: | PARTS MOTOR-DC ASSY M SP |
Парткод: | 302KV94290 |
Цена: | 6 300 ₽ |
Деталь: | PARTS MOTOR-DC ASSY C SP |
Парткод: | 302KV94280 |
Цена: | 6 300 ₽ |
Деталь: | PARTS MOTOR-DC ASSY Y SP |
Парткод: | 302KV94270 |
Цена: | 6 300 ₽ |
Деталь: | PARTS MOTOR-DC ASSY LSU SP |
Парткод: | 302KV94310 |
Цена: | 6 500 ₽ |
Деталь: | FAN POWER PWB 50 |
Парткод: | 302F944160 |
Цена: | 4 600 ₽ |
Деталь: | FAN MOTOR |
Парткод: | 302HN44010 |
Деталь: | MOTOR FUSER |
Парткод: | 302HN44090 |
Деталь: | SWITCH SIZE |
Парткод: | 302HN44180 |
Деталь: | FAN MOTOR |
Парткод: | 302HN44210 |
Деталь: | SENSOR OPT. |
Парткод: | 7NXGP1S173LCH01 |
Деталь: | HINGE LID L |
Парткод: | 302KV02532 |
Деталь: | CAM TONER SUPPLY |
Парткод: | 302KV02461 |
Деталь: | DUCT LEFT INNER |
Парткод: | 302KV02250 |
Деталь: | BELT S2M Z371 |
Парткод: | 302KV02A90 |
Деталь: | GUIDE CASSETTE L |
Парткод: | 302KT02180 |
Деталь: | MOTOR-DC ASSY LIFT |
Парткод: | 302KV00160 |
Деталь: | GUIDE TOP L |
Парткод: | 302KV02170 |
Деталь: | HOLDER TONER MOTOR |
Парткод: | 302KV02240 |
Деталь: | GUIDE CONTAINER |
Парткод: | 302KV02281 |
Деталь: | HOLDER RFID |
Парткод: | 302KV02290 |
Деталь: | GEAR Z50S |
Парткод: | 302KV02680 |
Деталь: | GEAR Z40R |
Парткод: | 302KV02A60 |
Деталь: | PULLEY P27 |
Парткод: | 302KV02A70 |
Деталь: | CONN.CORD ASSY S03535 |
Парткод: | 302KV46030 |
Деталь: | HOLDER GEAR |
Парткод: | 302KT02170 |
Деталь: | GEAR Z33S-Z13S |
Парткод: | 302KT02150 |
Деталь: | GEAR Z41S |
Парткод: | 302KV02B70 |
Деталь: | GEAR Z36R-Z35R |
Парткод: | 302KV02B00 |
Деталь: | GEAR Z16S |
Парткод: | 302KV02670 |
Деталь: | DV-560 US (K) |
Парткод: | 302HN93253 |
Деталь: | DV-560(K) |
Парткод: | 302HN93013 |
Деталь: | DV-560 US (M) |
Парткод: | 302HN93283 |
Деталь: | DV-560(M) |
Парткод: | 302HN93043 |
Деталь: | DV-560 US (C) |
Парткод: | 302HN93273 |
Деталь: | DV-560(C) |
Парткод: | 302HN93033 |
Деталь: | DV-560 US (Y) |
Парткод: | 302HN93263 |
Деталь: | DV-560(Y) |
Парткод: | 302HN93023 |
Деталь: | STOPPER HOOK |
Парткод: | 302KT09111 |
Деталь: | SPRING STOPPER HOOK |
Парткод: | 302KT09170 |
Деталь: | CT-591 |
Парткод: | 302KT93041 |
Деталь: | DR-590A |
Парткод: | 302KV93090 |
Деталь: | GEAR Z36L |
Парткод: | 302KV31130 |
Цена: | 60 ₽ |
Деталь: | ARM CLUTCH C |
Парткод: | 302KV31170 |
Цена: | 60 ₽ |
Деталь: | SPRING CLUTCH B |
Парткод: | 302KV31190 |
Цена: | 60 ₽ |
Деталь: | GEAR Z50R |
Парткод: | 302KV31091 |
Цена: | 70 ₽ |
Деталь: | MOTOR-DC ASSY DLP |
Парткод: | 302KV00070 |
Цена: | 900 ₽ |
Деталь: | PARTS DRIVE MPF ASSY SP |
Парткод: | 302KV94230 |
Цена: | 6 700 ₽ |
Деталь: | PARTS DRIVE PRESS ASSY SP |
Парткод: | 302KV94220 |
Цена: | 6 700 ₽ |
Деталь: | CLUTCH 50 Z35R |
Парткод: | 302KV44041 |
Цена: | 900 ₽ |
Деталь: | DR-590B |
Парткод: | 302KV93101 |
Деталь: | PARTS DRIVE FEED ASSY SP |
Парткод: | 302KV94211 |
Цена: | 11 500 ₽ |
Деталь: | PANEL UNIT, MFC9840CDW |
Парткод: | FK-590 |
Цена: | 10 600 ₽ |
Деталь: | Блок лазера |
Парткод: | LK-595A |
Цена: | 18 300 ₽ |
Деталь: | Блок лазера |
Парткод: | LK-595B |
Цена: | 20 000 ₽ |
Деталь: | Formatter, exchange, HP Color LaserJet 3000dn and 3000dtn Series only (256 MB) |
Парткод: | 302PV94050 |
Цена: | 42 200 ₽ |
Деталь: | PARTS FRAME ISU TOP ASSY SP |
Парткод: | 302KW94070 |
Деталь: | PARTS CARRIAGE ASSY |
Парткод: | 302M893012 |
Деталь: | PARTS MOTOR ISU SP |
Парткод: | 302LW94060 |
Деталь: | HOOK ISU |
Парткод: | 302KW17291 |
Деталь: | FRAME ISU BOTTOM |
Парткод: | 302M817012 |
Деталь: | LEVER LINK |
Парткод: | 302M817070 |
Деталь: | CONN.CORD ASSY S03709 |
Парткод: | 302M846070 |
Деталь: | Редуктор, в сборе |
Парткод: | DR-590A |
Цена: | 6 400 ₽ |
Деталь: | Редуктор, в сборе |
Парткод: | DR-590B |
Цена: | 10 500 ₽ |
Деталь: | PARTS COVER RIGHT UPPER ASSY SP |
Парткод: | 302KW94100 |
Деталь: | COVER RIGHT UPPER |
Парткод: | 302KW04040 |
Деталь: | PARTS COVER FRONT ASSY SP |
Парткод: | 302KW94090 |
Деталь: | PARTS COVER WASTE ASSY SP |
Парткод: | 302KT94060 |
Деталь: | PARTS COVER RIGHT ASSY SP |
Парткод: | 302KV94110 |
Деталь: | PARTS COVER RIGHT ASSY(B) SP |
Парткод: | 302PT94080 |
Деталь: | PARTS LID TOP M ASSY SP |
Парткод: | 302KW94080 |
Деталь: | LUTCH |
Парткод: | 302HN08140 |
Деталь: | COVER LEFT BOTTOM |
Парткод: | 302KT04010 |
Деталь: | COVER RIGHT BOTTOM |
Парткод: | 302KT04020 |
Деталь: | COVER CABLE |
Парткод: | 302KT04030 |
Деталь: | COVER LEFT |
Парткод: | 302KV04030 |
Деталь: | COVER LEFT REAR |
Парткод: | 302KV04060 |
Деталь: | Cover Right Rear |
Парткод: | 302KV04070 |
Деталь: | STRAP COVER REAR |
Парткод: | 302KV04130 |
Деталь: | COVER LEFT UPPER |
Парткод: | 302KW04030 |
Деталь: | COVER CONNECTOR |
Парткод: | 302M804010 |
Деталь: | COVER CONNECTOR |
Парткод: | 302PS04010 |
Деталь: | COVER CONNECTOR |
Парткод: | 302M904010 |
Деталь: | COVER CONNECTOR |
Парткод: | 302PY04010 |
Деталь: | PIN LID TOP |
Парткод: | 302KW04090 |
Деталь: | COVER REAR UPPER |
Парткод: | 302KW04050 |
Деталь: | RAIL ISU |
Парткод: | 302KW02050 |
Деталь: | RAIL ISU B |
Парткод: | 302KW02170 |
Деталь: | HOLDER SPRING ISU |
Парткод: | 302KW02160 |
Деталь: | RAIL LID TOP |
Парткод: | 302KW17251 |
Деталь: | MC-590 |
Парткод: | 302KV93121 |
Деталь: | DK-590 |
Парткод: | 302KV93017 |
Деталь: | 3LJ94070 |
Парткод: | 303LJ94070 |
Деталь: | 3M694010 |
Парткод: | 303M694010 |
Деталь: | 3LJ94120 |
Парткод: | 303LJ94120 |
Цена: | 4 700 ₽ |
Деталь: | 3M694030 |
Парткод: | 303M694030 |
Цена: | 5 600 ₽ |
Деталь: | 3LJ94010 |
Парткод: | 303LJ94010 |
Деталь: | 3LJ94061 |
Парткод: | 303LJ94061 |
Деталь: | 3LJ94140 |
Парткод: | 303LJ94140 |
Деталь: | 3LJ94150 |
Парткод: | 303LJ94150 |
Деталь: | 3HL10200 |
Парткод: | 303HL10200 |
Деталь: | 3K502200 |
Парткод: | 303K502200 |
Деталь: | 3LJ02080 |
Парткод: | 303LJ02080 |
Деталь: | 3LJ07050 |
Парткод: | 303LJ07050 |
Деталь: | 3LJ24080 |
Парткод: | 303LJ24080 |
Деталь: | 3LJ44040 |
Парткод: | 303LJ44040 |
Цена: | 4 500 ₽ |
Деталь: | 3M602020 |
Парткод: | 303M602020 |
Деталь: | 3M602030 |
Парткод: | 303M602030 |
Деталь: | 3M602070 |
Парткод: | 303M602070 |
Деталь: | 3M604011 |
Парткод: | 303M604011 |
Деталь: | 3M604021 |
Парткод: | 303M604021 |
Деталь: | 36211110 |
Парткод: | 36211110 |
Цена: | 750 ₽ |
Деталь: | 3BR07040 |
Парткод: | 3BR07040 |
Цена: | 420 ₽ |
Деталь: | NX052600 |
Парткод: | 7NXSG2481+++H01 |
Деталь: | 3LJ02051 |
Парткод: | 303LJ02051 |
Деталь: | 2H724180 |
Парткод: | 302H724180 |
Деталь: | 3K507102 |
Парткод: | 303K507102 |
Деталь: | 3M602050 |
Парткод: | 303M602050 |
Деталь: | PARTS TRANSFER ASSY SP |
Парткод: | 302KV94160 |
Цена: | 6 100 ₽ |
Деталь: | PARTS CONVEYING ASSY SP |
Парткод: | 302KV94171 |
Деталь: | HOOK DU RELEASE |
Парткод: | 302KV29102 |
Деталь: | ACTUATOR FD |
Парткод: | 302KV28050 |
Деталь: | GEAR Z25S-Z19S |
Парткод: | 302KV28101 |
Цена: | 60 ₽ |
Деталь: | GEAR Z19S |
Парткод: | 302KV28140 |
Цена: | 60 ₽ |
Деталь: | ROLLER EXIT |
Парткод: | 302KV28070 |
Цена: | 750 ₽ |
Деталь: | LABEL MULTI LANGUAGE |
Парткод: | 302KV34090 |
Деталь: | PARTS DU REAR COVER ASSY SP |
Парткод: | 302KV94254 |
Деталь: | Узел подачи бумаги из кассеты, в сборе |
Парткод: | 302KV94192 |
Цена: | 2 800 ₽ |
Деталь: | PARTS FAX UNIT U SP |
Парткод: | 302KX94051 |
Деталь: | PARTS FAX UNIT E SP |
Парткод: | 302KX94041 |
Деталь: | PARTS FAX UNIT U SP |
Парткод: | 302PL94040 |
Деталь: | PARTS FAX UNIT E SP |
Парткод: | 302PL94020 |
Деталь: | PARTS FAX UNIT AS SP |
Парткод: | 302PL94050 |
Деталь: | PARTS PWB MAIN ASSY SP |
Парткод: | 302M894033 |
Деталь: | PARTS PWB MAIN ASSY SP EU |
Парткод: | 302M894044 |
Деталь: | PARTS PWB MAIN ASSY SP |
Парткод: | 302M994023 |
Деталь: | PARTS PWB MAIN ASSY SP EU |
Парткод: | 302M994034 |
Деталь: | PARTS PWB MAIN ASSY SP |
Парткод: | 302PX94020 |
Деталь: | PARTS PWB MAIN ASSY SP EU |
Парткод: | 302PX94030 |
Деталь: | PARTS PWB MAIN ASSY SP |
Парткод: | 302PY94020 |
Деталь: | PARTS PWB MAIN ASSY SP EU |
Парткод: | 302PY94030 |
Деталь: | PARTS PWB ASSY EXIT SP |
Парткод: | 302KT94080 |
Деталь: | PARTS HIGH VOLTAGE UNIT SP |
Парткод: | 302KV94060 |
Деталь: | PARTS SWITCHING REGULATOR 100V SP |
Парткод: | 302KW94040 |
Деталь: | PARTS SWITCHING REGULATOR 230V SP |
Парткод: | 302KW94050 |
Деталь: | PARTS SWITCHING REGULATOR 230V SP |
Парткод: | 302PV94020 |
Деталь: | INLET ASSY |
Парткод: | 302KV00100 |
Деталь: | INLET ASSY |
Парткод: | 302KV00190 |
Деталь: | SW. MICRO |
Парткод: | 7SM010104+++H01 |
Деталь: | SW.PUSH |
Парткод: | 7SP01000005+H01 |
Деталь: | FAN POWER PWB 50 |
Парткод: | 302F944160 |
Цена: | 4 600 ₽ |
Деталь: | FOOT |
Парткод: | 302HN02611 |
Деталь: | FAN MOTOR |
Парткод: | 302HN44010 |
Деталь: | PARTS TONER FULL DETECT SP |
Парткод: | 302KV94370 |
Деталь: | ACTUATOR DETECTION CONTAINER |
Парткод: | 302KV02480 |
Деталь: | ACTUATOR PUSH SWITCH |
Парткод: | 302KV02C70 |
Деталь: | SENSOR OPT. |
Парткод: | 7NXGP1S173LCH01 |
Деталь: | SW.PUSH |
Парткод: | 7SP01000001+H01 |
Деталь: | RATCHET SHUTTER |
Парткод: | 302KV02501 |
Деталь: | SPRING JOINT SHUTTER |
Парткод: | 302KV02A21 |
Деталь: | HOLDER JOINT |
Парткод: | 302KV02510 |
Деталь: | CONN.CORD ASSY S03577 |
Парткод: | 302KV46390 |
Деталь: | COVER INNER |
Парткод: | 302KV04080 |
Деталь: | LABEL MPF |
Парткод: | 302KV34080 |
Деталь: | HINGE LID R |
Парткод: | 302KV02542 |
Деталь: | LEVER INTERLOCK |
Парткод: | 302KV02521 |
Деталь: | SEAL BRACKET FRONT |
Парткод: | 302KV02E30 |
Деталь: | GUIDE TOP R |
Парткод: | 302KV02180 |
Деталь: | BRACKET FRONT HV |
Парткод: | 302KV02232 |
Деталь: | RACK JOINT SHUTTER |
Парткод: | 302KV02451 |
Деталь: | CONN.CORD ASSY S03704 |
Парткод: | 302M846021 |
Деталь: | CONN.CORD ASSY S03871 |
Парткод: | 302PX46020 |
Деталь: | CONN.CORD ASSY S03708 |
Парткод: | 302M846060 |
Деталь: | GEAR Z16S |
Парткод: | 302KV02670 |
Деталь: | WT-590 |
Парткод: | 302KV93110 |
Деталь: | POWER CORD(120) |
Парткод: | 3019527401 |
Деталь: | PARTS AC CORD EU SP |
Парткод: | 302FV94010 |
Деталь: | AC CORD ASSY |
Парткод: | 302FV45040 |
Деталь: | PARTS WASTE TONER ASSY SP |
Парткод: | 302KV94470 |
Деталь: | LK-5135 |
Парткод: | 302PA93011 |
Деталь: | LK-595A |
Парткод: | 302PT93011 |
Деталь: | LK-5136 |
Парткод: | 302PA93021 |
Деталь: | LK-595B |
Парткод: | 302PT93021 |
Деталь: | TR-590 |
Парткод: | 302KV93070 |
Деталь: | Блок проявки |
Парткод: | DV-560C |
Цена: | 12 800 ₽ |
Деталь: | Блок проявки |
Парткод: | DV-560K |
Цена: | 12 800 ₽ |
Деталь: | Блок проявки |
Парткод: | DV-560M |
Цена: | 12 800 ₽ |
Деталь: | Блок проявки |
Парткод: | DV-560Y |
Цена: | 12 800 ₽ |
Деталь: | Узел переноса заряда в драм-картридже, в сборе |
Парткод: | MC-590 |
Цена: | 6 400 ₽ |
Деталь: | Узел переноса изображения |
Парткод: | TR-590 |
Цена: | 15 700 ₽ |
Деталь: | FK-590(U) |
Парткод: | 302KV93050 |
Деталь: | FK-590(E) |
Парткод: | 302KV93040 |
Деталь: | PARTS COVER MPF ASSY SP |
Парткод: | 302KV94130 |
Деталь: | PARTS PLATE BOTTOM MPF ASSY SP |
Парткод: | 302KV94150 |
Деталь: | PARTS SEPARATOR MPF ASSY SP |
Парткод: | 302KV94140 |
Деталь: | PULLEY FEED DU |
Парткод: | 302F929050 |
Деталь: | ROLLER M/P ASSY /43487B0027 A4 |
Парткод: | 5AAVR0LL+051 |
Цена: | 800 ₽ |
Деталь: | LABEL ENERGY STAR |
Парткод: | 302G634070 |
Деталь: | FRAME MPF |
Парткод: | 302KV08041 |
Деталь: | GUIDE MPF FEED UP |
Парткод: | 302KV08150 |
Деталь: | GUIDE MPF FEED LOW A |
Парткод: | 302KV08160 |
Деталь: | GUIDE MPF FEED LOW B |
Парткод: | 302KV08281 |
Деталь: | SHAFT MIDDLE PULLEY |
Парткод: | 302KV06230 |
Деталь: | BUSH SPRING FEED |
Парткод: | 302KV24090 |
Деталь: | SPRING PULLEY MPF |
Парткод: | 302KV08120 |
Деталь: | PARTS PWB PANEL MAIN ASSY |
Парткод: | 302M894051 |
Деталь: | PARTS PWB PANEL MAIN ASSY SP |
Парткод: | 302PX94040 |
Деталь: | COVER PANEL A |
Парткод: | 302K305030 |
Деталь: | PANEL OPERATION L |
Парткод: | 302M805020 |
Деталь: | PANEL OPERATION L |
Парткод: | 302M905020 |
Деталь: | PANEL OPERATION R |
Парткод: | 302M805030 |
Деталь: | PANEL OPERATION M |
Парткод: | 302M805040 |
Деталь: | COVER IC-CARD |
Парткод: | 302M805050 |
Деталь: | COVER IC-CARD SUB A |
Парткод: | 302M805090 |
Деталь: | SHEET OPERATION L E |
Парткод: | 302M834110 |
Деталь: | SHEET OPERATION L E |
Парткод: | 302M934110 |
Деталь: | SHEET OPERATION L E |
Парткод: | 302PX34020 |
Деталь: | SHEET OPERATION L E |
Парткод: | 302PY34020 |
Деталь: | SHEET OPERATION L E |
Парткод: | 302PX34260 |
Деталь: | SHEET OPERATION L E |
Парткод: | 302PY34320 |
Деталь: | SHEET OPERATION R E |
Парткод: | 302M834310 |
Деталь: | SHEET OPERATION R E |
Парткод: | 302M934310 |
Деталь: | SHEET OPERATION R E |
Парткод: | 302PX34180 |
Деталь: | SHEET OPERATION R E |
Парткод: | 302PY34210 |
Деталь: | COVER IC-CARD SUB |
Парткод: | 302M805060 |
Деталь: | PARTS OPERATION UNIT SP |
Парткод: | 302M894010 |
Деталь: | PARTS OPERATION UNIT SP |
Парткод: | 302M994011 |
Деталь: | PARTS OPERATION ASSY SP |
Парткод: | 302PX94010 |
Деталь: | PARTS OPERATION ASSY SP |
Парткод: | 302PY94010 |
Деталь: | PARTS COVER IC-CARD SET SP |
Парткод: | 302M894070 |
Деталь: | PARTS COVER IC-CARD SET SP |
Парткод: | 302M894020 |
Коды ошибок
0030
0070
0100
0120
0130
0140
0150
0170
0180
0600
0610
0640
0830
0840
0870
0920
0930
1010
1020
1030
1500
1510
1520
1530
1600
1610
1620
1630
1800
2100
2200
2330
2340
2500
2600
2610
2730
2740
2820
3100
3200
3300
3500
4001
4002
4201
4202
4203
4204
4600
4700
5301
5302
5303
5304
6000
6020
6030
6400
7001
7002
7003
7004
7401
7402
7403
7404
7411
7412
7413
7414
9500 ... 9520
9530
F000
F010
F020
F040
F041
F050
F051
F278
Описание
Error code: | 0030 |
Description: | FAX control PWB system error Processing with the fax software was disabled due to a software problem. |
Causes: | Defective FAX control PWB. |
Remedy: | FAX control PWB 1. Turn the main power swtch off and after 5 seconds, re-mount the FAX controller PWB, then turn power on. 2. Reinstall the fax software. 3. Replace the FAX control PWB. |
Error code: | 0070 |
Description: | FAX control PWB incompatible detection error Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. |
Causes: | Defective FAX software. Defective FAX control PWB. |
Remedy: | FAX control PWB (The FAX PWB installed will not be the one designed for the machine.) 1. Install the FAX system designed for the model. 2. Reinstall the fax software. |
Error code: | 0100 |
Display: | MAINTENANCE CALL 0100 |
Description: | Backup memory device error |
Causes: | Defective flash memory. Defective main PWB. |
Remedy: | EEPROM (main PWB) 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM on the main circuit PWB is peroperly installed on the main circuit PWB and, if not, re-install it. 3. Replace the main PWB |
Error code: | 0120 |
Description: | There is a problem with Thermistor for Pre-Heater. |
Causes: | Thermistor Cable has short circuited or cutline. Thermistor has a problem. |
Remedy: | Check Cable connection around Thermistor Thermistor replacement |
Error code: | 0130 |
Description: | There is a problem with Thermistor for Print Heater. |
Causes: | Thermistor cable has short circuited or cutline. Thermistor has a problem. |
Remedy: | Check Cable connection around Thermistor Thermistor replacement |
Error code: | 0140 |
Description: | There is a problem with Thermistor for dryer. |
Causes: | Thermistor cable has short circuited or cutline. Thermistor has a problem. |
Remedy: | Check Cable connection around Thermistor Thermistor replacement |
Error code: | 0150 |
Description: | Even though the machine carries out the regular movement, the output of Slider Sensor does not reach the expected value. |
Causes: | Slider Motor has a problem. Slider Sensor has a problem. Wiring or Flexible Cable has short circuitted or cut-line. Servo Board has a problem. |
Remedy: | Check Cable connection of Servo Board Check Cable connection of Junction Board Slider Motor replacement Slider Sensor replacement Wiring or Flexible Cable replacement Servo Board replacement |
Error code: | 0170 |
Description: | Even though the machine carries out the regular movement, the output of Supply Pump 1 Sensor does not reach the expected value. |
Causes: | Supply Pump 1 Motor has a problem. Supply Pump 1 Sensor has a problem. Supply Pump 1 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem. |
Remedy: | Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 1 Magnet Supply Pump 1 Motor replacement Supply Pump 1 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement |
Error code: | 0180 |
Description: | Even though the machine carries out the regular movement, the output of Maintenance Liquid Pump Sensor does not reach the expected value. |
Causes: | Maintenance Liquid Pump Motor has a problem. Maintenance Liquid Pump Sensor has a problem. Maintenance Liquid Pump Magnet has dropped out. Wiring or Flexible Cable has short circuitted |
Remedy: | Check Cable connection of Servo Board Check Cable connection of Junction Board Maintenance Liquid Pump Motor replacement Maintenance Liquid Pump Sensor replacement Wiring or Flexible Cable replacement Servo Board replacement |
Error code: | 0600 |
Display: | Print Unable 06 Turn the power off and then back on again. |
Description: | Expanded memory (DIMM) installing error The expansion memory modules (DIMM) are not correctly mounted. |
Causes: | Improper installation expanded memory (DIMM). |
Remedy: | Improper installation expanded memory (DIMM). Check the installation of the expanded memory (DIMM). |
Error code: | 0610 |
Description: | Expanded memory (DIMM) error The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly. |
Causes: | Defective expanded memory (DIMM). Defective main PWB. |
Remedy: | Defective expanded memory (DIMM). Replace the expanded memory (DIMM) and check for correct operation. Defective main PWB. Replace the main PWB and check for correct operation. |
Error code: | 0640 |
Description: | Hard disk error The hard disk cannot be accessed. |
Causes: | Defective hard disk. Defective main PWB. |
Remedy: | HDD 1. If an abnormal noise is heard from the HDD, replace the HDD. 2. Check the SATA wiring between the HDD and the main circuit PWB for loose connection, disconnection and damages, and that it is connected into the correct terminal. Main PWB: YC1,YC27 3. Replace the SATA cable. 4. Execute U024 to initialize (FULL) the HDD. 5. If an error is detected after executing U024, replace the HDD. Lack of HDD capacity 1. Confirm the total capacity of the HDD if it is more than 320GB. Change the HDD or add it in case of lacking in capacity. Main PWB Replace the main PWB. |
Error code: | 0830 |
Description: | FAX control PWB flash program area checksum error A checksum error occurred with the program of the FAX control PWB |
Causes: | Defective FAX software. Defective FAX control PWB. |
Remedy: | FAX software 1. Reinstall the fax software. FAX control PWB 1. Execute initializing by U600.(Refer to the FAX service manual) 2. Replace the FAX control PWB. |
Error code: | 0840 |
Description: | Faults of RTC (“Time for maintenance T” is displayed) [Check at power up] The RTC setting has reverted to a previous state. The machine has not been powered for 5 years (compared to the settings stored periodically in the EEPROM). The RTC setting is older than 00:01 on January 1, 2000. [Checked periodically (in 5- minute interval) after powered up] The RTC setting has reverted to a state older than the last time it was checked. 10 minutes have been passed since the previous check. After C840 is detected, the machine enters in disconnection mode after the main power switch has been switched on and off and indicates ‘Maintenance T.’ |
Causes: | The battery is disconnected from the main PWB Defective main PWB. |
Remedy: | Battery (main PWB) 1. Make sure that the back-up batteries on the main PWB are not short-circuited. 2. Reset Maintenance T by executing U906. 3. If the same C call is displayed when power is switched on and off, replace the back up battery. 4. If communication error (due to a noise, etc.) is present with the RTC on the main circuit PWB, check the PWB is properly grounded. Main PWB Replace the main PWB |
Error code: | 0870 |
Description: | PCFAX control PWB to main PWB high capacity data transfer error High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. |
Causes: | Improper installation FAX control PWB. Defective FAX control PWB or main PWB. |
Remedy: | FAX control PWB 1. Turn the main power swtch off and after 5 seconds, re-mount the FAX controller PWB, then turn power on. 2. Replace the FAX control PWB. HDD Execute U024 to initialize the HDD. Main PWB Replace the main PWB. |
Error code: | 0920 |
Description: | Fax file system error The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. |
Causes: | Defective FAX control PWB. |
Remedy: | FAX control PWB 1. Execute initializing by U600 (Refer to the FAX service manual). 2. Replace the FAX control PWB. |
Error code: | 0930 |
Description: | EEPROM bus error |
Causes: | Defective drum PWB (EEPROM). Defective engine PWB (EEPROM). Defective engine PWB. Defective main PWB. |
Remedy: | Defective drum PWB (EEPROM). Replace the drum unit. Defective engine PWB (EEPROM). Replace the engine PWB and check for correct operation. Defective engine PWB. Replace the engine PWB and check for correct operation. Defective main PWB. Replace the main PWB and check for correct operation. |
Error code: | 1010 |
Display: | Problem with Printhead L/R Chk printing results |
Description: | Lift motor 1 error After cassette 1 is inserted, lift sensor 1 does not turn on within 12 s. This error is detected 4 times successively. The lock signal of the motor is detected continuously for 1 s. This error is detected 4 times successively. |
Causes: | Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective lift motor 1. Defective engine PWB. |
Remedy: | Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace. Lift motor 1 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift motor 1 and Feed PWB 2 (YC3) Feed PWB 2 (YC1) and Engine PWB (YC4) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the lift motor 1. Lift sensor 1 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift sensor 1 and Feed PWB 2 (YC8) Feed PWB 2 (YC1) and Engine PWB (YC4) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the lift sensor1. Feed PWB 2 Replace the Feed PWB 2. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 1020 |
Description: | Lift motor 2 error After cassette 2 is inserted, lift sensor 2 does not turn on within 12 s. This error is detected 4 times successively. The lock signal of the motor is detected continuously for 1 s. This error is detected 4 times successively. |
Causes: | Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective lift motor 2. Defective engine PWB. |
Remedy: | Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace. Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift motor 2 and Feed PWB 2 (YC3) Feed PWB 2 (YC1) and Engine PWB (YC4) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the lift motor 2. Lift sensor 2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift sensor 2 and Feed PWB 2 (YC8) Feed PWB 2 (YC1) and Engine PWB (YC4) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the lift sensor2. Feed PWB 2 Replace the Feed PWB 2. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 1030 |
Display: | GARO W1221 |
Description: | PF lift motor 1 error (paper feeder) After cassette 3 is inserted, PF lift sensor 1 does not turn on within 12 s. This error is detected 5 times successively. During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively. However, the first 1 s after motor is turned on is excluded from detection. |
Causes: | Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective PF lift motor 1. Defective PF main PWB. |
Remedy: | Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7) Defective drive transmission system of motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective PF lift motor 1. Replace the PF lift motor 1. Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1500 |
Display: | Print Unable 15 Turn the power off and then back on again. |
Description: | PF heater 1 high temperature error (paper feeder 1) A temperature higher than 75C/167F is detected. |
Causes: | Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 1 and PF main PWB (YC111) Shorted PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1510 |
Description: | PF heater 2 high temperature error (paper feeder 1) A temperature higher than 75C/167F is detected. |
Causes: | Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 2 and PF main PWB (YC111) Shorted PF thermistor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1520 |
Description: | PF heater 1 high temperature error (paper feeder 2) A temperature higher than 75C/167F is detected. |
Causes: | Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 1 and PF main PWB (YC111) Shorted PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1530 |
Description: | PF heater 2 high temperature error (paper feeder 2) A temperature higher than 75C/167F is detected. |
Causes: | Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 2 and PF main PWB (YC111) Shorted PF thermistor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1600 |
Description: | PF heater 1 low temperature error (paper feeder 1) An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. |
Causes: | Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF heater 1 and PF heater PWB (YC1) PF heater PWB (YC3) and PF main PWB (YC113) PF thermistor 1 and PF main PWB (YC114) PF thermistor 1 installed incorrectly. Check the installation of the PF thermistor 1. Defective PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Broken PF heater 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF heater PWB or PF main PWB. Replace the PF heater PWB or PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1610 |
Description: | PF heater 2 low temperature error (paper feeder 1) An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. |
Causes: | Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF heater 2 and PF heater PWB (YC2) PF heater PWB (YC3) and PF main PWB (YC113) PF thermistor 2 and PF main PWB (YC115) PF thermistor 2 installed incorrectly. Check the installation of the PF thermistor 2. Defective PF thermistor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Broken PF heater 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF heater PWB or PF main PWB. Replace the PF heater PWB or PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1620 |
Description: | PF heater 1 low temperature error (paper feeder 2) An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. |
Causes: | Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF heater 1 and PF heater PWB (YC1) PF heater PWB (YC3) and PF main PWB (YC113) PF thermistor 1 and PF main PWB (YC114) PF thermistor 1 installed incorrectly. Check the installation of the PF thermistor 1. Defective PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Broken PF heater 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF heater PWB or PF main PWB. Replace the PF heater PWB or PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1630 |
Description: | PF heater 2 low temperature error (paper feeder 2) An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. |
Causes: | Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF heater 2 and PF heater PWB (YC2) PF heater PWB (YC3) and PF main PWB (YC113) PF thermistor 2 and PF main PWB (YC115) PF thermistor 2 installed incorrectly. Check the installation of the PF thermistor 2. Defective PF thermistor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Broken PF heater 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF heater PWB or PF main PWB. Replace the PF heater PWB or PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 1800 |
Description: | Paper feeder communication error A communication error from paper feeder is detected 10 times in succession. |
Causes: | Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB. |
Remedy: | Paper feeder Check the wiring connection status with the main unit and, if necessary, try connecting it again. PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB (YC13) and Engine PWB (YC19) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PF main PWB (Refer to the service manual for the paper feeder). Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 2100 |
Description: | NIB self test failed. |
Causes: | Turn off the machine and turn it back on. Replace the NIB if this error is frequent. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing motor and engine PWB (YC14) Defective drive transmission system of the developing motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective developing motor. Replace the developing motor. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 2200 |
Description: | Main motor steady-state error After main motor is stabilized, the ready signal is at the H level for 2 s continuously. |
Causes: | Main motor. Engine PWB. |
Remedy: | Main motor 1. To check the motor operation execute U030 Main (main motor). 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Main motor and Engine PWB (YC16) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the main motor. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 2330 |
Description: | Fuser pressure release motor error When the fuser pressure release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser pressure release motor and engine PWB (YC38) Defective drive transmission system of the fuser pressure release motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective fuser pressure release motor. Replace the fuser pressure release motor. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 2340 |
Description: | Fuser pressure release motor time-out error When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s. |
Causes: | Defective connector cable or poor contact in the connector.Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser pressure release motor and engine PWB (YC38) Defective drive transmission system of the fuser pressure release motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective fuser pressure release motor. Replace the fuser pressure release motor. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 2500 |
Description: | Paper feed motor error After paper feed motor is driven, the ready signal does not turn to L within 2 s. After paper feed motor is stabilized, the ready signal is at the H level for 1 s continuously. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective paper feed motor. Defective engine PWB. |
Remedy: | Paper feed motor 1. To check the motor operation execute U030 Feed (paper feed motor). 2. Check the paper feed roller and drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Paper feed motor and Feed PWB 2(YC2) Feed PWB 2(YC1) and Engine PWB (YC4) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the paper feed motor. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 2600 |
Description: | PF paper feed motor error (large capacity feeder) After PF paper feed motor is driven, the ready signal does not turn to L within 2 s. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective PF paper feed motor. Defective PF main PWB. |
Remedy: | PF paper feed motor 1. To check the feed unit operation, execute U247 LCF- Motor ON. 2. Check the paper feed roller and drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF paper feed motor and PF main PWB (YC16) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the paper feed motor. PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 2610 |
Description: | PF paper feed motor error (paper feeder) After PF paper feed motor is driven, the ready signal does not turn to L within 2 s. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective PF paper feed motor. Defective PF main PWB. |
Remedy: | PF paper feed motor 1. To check the feed unit operation, execute U247 2PF - Motor ON. 2. Check the paper feed roller and drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF paper feed motor and PF main PWB (YC16) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the paper feed motor. PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder). |
Error code: | 2730 |
Description: | Secondary transfer release motor error When the transfer release motor is driven, the transfer release sensor does not turn on/off for 5 s. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective transfer release motor. Defective engine PWB. |
Remedy: | Transfer release motor 1. To check the motor operation, execute U030 Press Release. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Transfer release motor and relay PWB (YC14) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the Transfer release motor. Transfer release sensor 1. When abnormal noise is observed at the execution of Press Release of U030 motor operation check. 2. Check that the sensor and its mounting board are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 4. Replace the Transfer release motor. Paper conveying unit 1. The main-unit access drawer of the paper conveying unit has no foreign objects adhered or no distorted pins and, if necessary, repair. 2. Check the paper conveying unit is firmly closed. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Relay PWB (YC1) and Feed PWB 1(YC14) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the paper conveying unit and execute U052. Feed PWB 1 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Feed PWB 1 (YC1) and Engine PWB (YC6) 2. Check that the IC on the feed circuit PWB1 is not damaged (by an overcurrent or foreign object) and, if necessary, replace. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 2740 |
Description: | Developing release motor time-out error When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing release motor and engine PWB (YC35) Defective drive transmission system of the developing release motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective developing release motor. Replace the developing release motor. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 2820 |
Display: | Cannot adjust printhead. Press Online to clear the error and readjust printhead. |
Description: | Intermediate transfer belt motor steady-state error After transfer motor is stabilized, the ready signal is at the H level for 5 s continuously. The counter value obtained by timer capture is lower than 2200 for 10 times in a row. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective transfer motor. Defective engine PWB. |
Remedy: | Transfer motor 1. To check the motor operation, execute U030 Belt Meand. 2. Rotate the roller, driving gear by the hand and check that they are not unusually loaded. 3. Clean the intermediate transfer belt unit. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Transfer motor and Feed PWB 1(YC13) Feed PWB 1(YC2) and Engine PWB (YC5) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the Transfer motor. Feed PWB 1 Replace the Feed PWB 1. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 3100 |
Description: | Scanner carriage error The home position is not correct when the power is turned on, at the end of a reading process of the table and document processor. |
Causes: | Defective connector cable or poor contact in the connector. Defective home position sensor. Defective scanner motor. Defective ISC PWB. Defective main PWB. |
Remedy: | The scanner mirror frame is being locked after setup. Check whether the scanner mirror frame has been unlocked and unlock if necessary. Scanner motor 1. To check the scanner motor, execute U073. 2. Move the scanner by the hand to check whether it is unusually difficult to move. 3. Check that the optical wire rope is not disengaged and engage the wire. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Scanner motor and ISC PWB (YC5) ISC PWB (YC3) and Main PWB (YC11) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the scanner motor. Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Home position sensor and ISC PWB (YC8) 3. Replace the home position sensor. ISC PWB Replace the ISC PWB and execute U411. Main PWB Replace the main PWB. |
Error code: | 3200 |
Description: | Exposure lamp error When input value at the time of LED lamp PWB illumination does not exceed the threshold value between 5 s. |
Causes: | Defective connector cable or poor contact in the connector. Defective LED lamp PWB. Defective ISC PWB. Defective main PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. LED lamp PWB and ISC PWB (YC6) CCD PWB (YC2) and ISC PWB (YC9) ISC PWB (YC3) and main PWB (YC11) Defective LED lamp PWB. Replace the LED lamp PWB and check for correct operation. Defective ISC PWB. Replace the ISC PWB and check for correct operation. Defective CCD PWB. Replace the ISU and check for correct operation. Defective main PWB. Replace the main PWB and check for correct operation. |
Error code: | 3300 |
Description: | Optical system (AGC) error One of the gains is FF or 00 during the CCD lamp AGC is being processed. |
Causes: | Defective connector cable or poor contact in the connector. Defective exposure lamp Defective CCD PWB. Defective ISC PWB. Defective main PWB. |
Remedy: | LED lamp PWB 1. To check the lamp, execute U061 CCD. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. LED lamp PWB and ISC PWB (YC6) CCD PWB (YC2) and ISC PWB (YC9) ISC PWB (YC3) and Main PWB (YC11) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. If the LED lamp won’t light, replace the LED PWB and execut U411. CCD PWB Replace the ISU and execute U411. ISC PWB Replace the ISC PWB and execute U411. Main PWB Replace the main PWB. |
Error code: | 3500 |
Description: | Communication error between scanner and ASIC An error code is detected. |
Causes: | Defective connector cable or poor contact in the connector. Defective ISC PWB. Defective main PWB. |
Remedy: | ISC PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. ISC PWB (YC3) and Main PWB (YC11) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the ISC PWB and execute U411. Main PWB Replace the main PWB. |
Error code: | 4001 |
Display: | ERROR E146-4001 Call for service. |
Description: | Polygon motor synchronization error After polygon motor is driven, the ready signal does not turn to L within 30 s. The polygon motor speed won’t stabilize within 10 s. |
Causes: | Defective connector cable or poor contact in the connector. Defective polygon motor. Defective engine PWB. |
Remedy: | Polygon motor (LSU) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Polygon motor and Engine PWB (YC15) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the laser scanner unit. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 4002 |
Display: | Drum End Soon:Y |
Description: | Polygon motor C synchronization error After polygon motor C is driven, the ready signal does not turn to L within 30 s. The polygon motor speed won’t stabilize within 10 s. |
Causes: | Defective connector cable or poor contact in the connector. Defective polygon motor C. Defective engine PWB. |
Remedy: | Polygon motor C (LSU) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Polygon motor C and LSU relay PWB (YC9) LSU relay PWB (YC3) and Engine PWB (YC12) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the laser scanner unit. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 4201 |
Display: | Replace Drum:BK |
Description: | BD steady-state error K The BD signal is not detected. |
Causes: | Defective connector cable or poor contact in the connector. Defective PD PWB. Defective engine PWB. |
Remedy: | PD PWB K (LSU) 1. Confirm that the FFC wiring connector is not distorted and connect the FFC wiring all the way in. Laser scanner unit and LSU relay PWB (YC3) LSU relay PWB (YC2) and Engine PWB (YC11) 2. If the FFC wiring is disconnected, shorted or grounded, replace the FFC wiring. 3. Replace the laser scanner unit. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 4202 |
Display: | Replace Drum:Y |
Description: | BD steady-state error C The BD signal is not detected. |
Causes: | Defective connector cable or poor contact in the connector. Defective PD PWB C. Defective engine PWB. |
Remedy: | PD PWB C (LSU) 1. Confirm that the FFC wiring connector is not distorted and connect the FFC wiring all the way in. Laser scanner unit and LSU relay PWB (YC10) LSU relay PWB (YC3) and Engine PWB (YC12) 2. If the FFC wiring is disconnected, replace the FFC wiring. 3. Replace the laser scanner unit. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 4203 |
Display: | Replace Drum:M |
Description: | BD steady-state error M The BD signal is not detected. |
Causes: | Defective connector cable or poor contact in the connector. Defective PD PWB M. Defective engine PWB. |
Remedy: | PD PWB M (LSU) 1. Confirm that the FFC wiring connector is not distorted and connect the FFC wiring all the way in. Laser scanner unit and LSU relay PWB (YC8) LSU relay PWB (YC3) and Engine PWB (YC12) 2. If the FFC wiring is disconnected, replace the FFC wiring. 3. Replace the laser scanner unit. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 4204 |
Display: | Replace Drum:C |
Description: | BD steady-state error Y The BD signal is not detected. |
Causes: | Defective connector cable or poor contact in the connector. Defective PD PWB Y. Defective engine PWB |
Remedy: | PD PWB Y (LSU) 1. Confirm that the FFC wiring connector is not distorted and connect the FFC wiring all the way in. Laser scanner unit and LSU relay PWB (YC12) LSU relay PWB (YC3) and Engine PWB (YC12) 2. If the FFC wiring is disconnected, replace the FFC wiring. 3. Replace the laser scanner unit. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 4600 |
Display: | Maintenance Replace Laser |
Description: | LSU cleaning motor error After LSU cleaning motor is driven, the ready signal does not turn to L within 2 s. After LSU cleaning motor is stabilized, the ready signal is at the H level for 1 s continuously. |
Causes: | Defective connector cable or poor contact in the connector. Defective drive transmission system of motor. Defective LSU cleaning motor. Defective engine PWB. |
Remedy: | LSU cleaning motor 1. Execute LSU cleaning using Adjustment/Maintenance of the system menu. 2. Rotate the drive gear and the cleaning spiral by the hand and check that they are not unusually loaded, and replace if it is damaged. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. LSU cleaning motor and Engine PWB (YC21) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the LSU cleaning motor. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 4700 |
Display: | Supplies WT Box End Soon |
Description: | VIDEO_ASIC device error Communication with the video ASIC has failed 5 times successively. After writing to the VIDEO ASIC, the error that the reading value from the same address does not match occurs 8 times successively. |
Causes: | Engine PWB. Main PWB |
Remedy: | Main PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check that the connectors on the main PWB are properly connected, and if not, re-connect them. 3. Replace the main PWB. |
Error code: | 5301 |
Description: | Broken cleaning lamp K wire When the cleaning lamp K is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. |
Causes: | Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit K and Drum relay PWB (YC2) Drum relay PWB (YC1) and engine PWB (YC34) Defective cleaning lamp K. Replace the drum unit K. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 5302 |
Description: | Broken cleaning lamp C wire When the cleaning lamp C is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. |
Causes: | Defective connector cable or poor contact in the connector. Defective cleaning lamp C. Defective engine PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit C and Drum relay PWB (YC4) Drum relay PWB (YC1) and engine PWB (YC34) Defective cleaning lamp C. Replace the drum unit C. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 5303 |
Description: | Broken cleaning lamp M wire When the cleaning lamp M is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. |
Causes: | Defective connector cable or poor contact in the connector. Defective cleaning lamp M. Defective engine PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit M and Drum relay PWB (YC3) Drum relay PWB (YC1) and engine PWB (YC34) Defective cleaning lamp M. Replace the drum unit M. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 5304 |
Description: | Broken cleaning lamp Y wire When the cleaning lamp Y is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. |
Causes: | Defective connector cable or poor contact in the connector. Defective cleaning lamp Y. Defective engine PWB. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit Y and Drum relay PWB (YC5) Drum relay PWB (YC1) and engine PWB (YC34) Defective cleaning lamp Y. Replace the drum unit Y. Defective engine PWB. Replace the engine PWB and check for correct operation. |
Error code: | 6000 |
Description: | Broken fuser heater wire Fuser thermistor 1 does not reach 100° C/212 °F even after 30 s during warming up. The detected temperature of fuser thermistor 1 does not reach the specified temperature (ready indication temperature) for 420 s in warming up after reached to 100° C/212 °F. |
Causes: | Defective connector cable or poor contact in the connector. Deformed connector pin. Defective triac. Fuser thermostat triggered. Defective fuser heater. Defective engine PWB. |
Remedy: | Fuser unit 1. Check that no paper jam is present. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and Engine PWB (YC26) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the Fuser unit Replace the Fuser unit. (Deteriorated sensitivity due to the toner adhered to the center thermistor.) Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. Power source PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Power source PWB (YC3) and fuser heater PWB (YC3) Fuser heater PWB (YC2) and feed PWB 1 (YC27) Feed PWB 1 (YC1) and Engine PWB (YC6) Fuser heater 1. Replace the fuser unit. |
Error code: | 6020 |
Description: | Abnormally high fuser thermistor 1 temperature Fuser thermistor 1 detects a temperature higher than 240°C/464°F for 1 s. |
Causes: | Deformed connector pin. Defective triac. Shorted fuser thermistor 1. Defective engine PWB. |
Remedy: | Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and Engine PWB (YC26) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 6030 |
Description: | Broken fuser thermistor 1 wire Input from fuser center thermistor 1 is 1010 or more (A/D value) continuously for 1 s. Verify if A/D read in the differential output won’t change by 4 or more when it was turned on for 10 seconds in a lowtemperature environment. |
Causes: | Defective connector cable or poor contact in the connector. Deformed connector pin. Defective triac. Broken fuser thermistor 1 wire. Fuser thermostat triggered. Defective fuser heater. Defective engine PWB. |
Remedy: | Fuser unit 1. Check that no paper jam is present. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and Engine PWB (YC26) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the Fuser unit. (Deteriorated sensitivity due to the toner adhered to the center thermistor.) Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. Fuser thermistor 1 1. Replace the Fuser unit. Fuser thermostat (triggered) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and fuser heater PWB (YC1) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit. |
Error code: | 6400 |
Display: | No Belt Unit Open the Front Cover, pull out all Drum Units completely and install the Belt Unit. |
Description: | Zero-cross signal error While fuser heater ON/OFF control is performed, the zerocross signal is not input within 3 s. |
Causes: | Fuser unit. |
Remedy: | Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser heater PWB (YC2) and feed PWB 1 (YC27) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the fuser heater PWB. |
Error code: | 7001 |
Description: | Toner motor error During the toner motor is driven, an event in which a locking was detected for 5 times in 200 ms intervals has occurred in 30 sets. |
Causes: | Defective connector cable or poor contact in the connector. Defective toner motor. Defective engine PWB. |
Remedy: | Toner container 1. Check that the spiral screw of the toner container can be rotated by the hand. 2. Check for broken gears and replace if any. Toner motor 1. Draw out the toner container and execute U135 to check the toner motor operation. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner motor and Engine PWB (YC27) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the Toner motor. Screw sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Screw sensor and Front PWB (YC5) Front PWB (YC2) and Engine PWB (YC7) 3. Replace the Screw sensor. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 7002 |
Description: | Toner motor C error During the toner motor is driven, an event in which a locking was detected for 5 times in 200 ms intervals has occurred in 30 sets. |
Causes: | Defective connector cable or poor contact in the connector. Defective screw sensor C. Defective toner motor C. Defective engine PWB. |
Remedy: | Toner container C 1. Check that the spiral screw of the toner container can be rotated by the hand. 2. Check for broken gears and replace if any. Toner motor C 1. Draw out the toner container and execute U135 to check the toner motor operation. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner motor C and Engine PWB (YC27) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the Toner motor C. Screw sensor C 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Screw sensor C and Engine PWB (YC27) 3. Replace the screw sensor C. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 7003 |
Description: | Toner motor M error During the toner motor is driven, an event in which a locking was detected for 5 times in 200 ms intervals has occurred in 30 sets. |
Causes: | Defective connector cable or poor contact in the connector. Defective screw sensor M. Defective toner motor M. Defective engine PWB. |
Remedy: | Toner container M 1. Check that the spiral screw of the toner container can be rotated by the hand. 2. Check for broken gears and replace if any. Toner motor M 1. Draw out the toner container and execute U135 to check the toner motor operation. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner motor M and Engine PWB (YC27) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the Toner motor M. Screw sensor M 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Screw sensor M and Engine PWB (YC27) 3. Replace the screw sensor M. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 7004 |
Description: | Toner motor Y error During the toner motor is driven, an event in which a locking was detected for 5 times in 200 ms intervals has occurred in 30 sets. |
Causes: | Defective connector cable or poor contact in the connector. Defective screw sensor Y. Defective toner motor Y. Defective engine PWB. |
Remedy: | Toner container Y 1. Check that the spiral screw of the toner container can be rotated by the hand. 1. Check for broken gears and replace if any. Toner motor Y 1. Draw out the toner container and execute U135 to check the toner motor operation. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner motor Y and Engine PWB (YC27) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the Toner motor Y. Screw sensor Y 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Screw sensor Y and Engine PWB (YC27) 3. Replace the screw sensor Y. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. |
Error code: | 7401 |
Description: | Developer unit type mismatch error Improper adaptation of the machine and developer unit is detected. |
Causes: | Defective connector cable or poor contact in the connector. Different type of the developer unit is installed. |
Remedy: | Different type of the developer unit is installed. Install the developer unit of the correct type. Developer unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Developer unit and Front PWB (YC7) Front PWB (YC2) and Engine PWB (YC8) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. |
Error code: | 7402 |
Description: | Developer unit C type mismatch error Absence of the developer unit C is detected. |
Causes: | Defective connector cable or poor contact in the connector. Different type of the developer unit is installed. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit C and front PWB (YC13) Front PWB (YC2) and engine PWB (YC10) Different type of the developer unit is installed. Install the correct developer unit. |
Error code: | 7403 |
Description: | Developer unit M type mismatch error Absence of the developer unit M is detected. |
Causes: | Defective connector cable or poor contact in the connector Different type of the developer unit is installed |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit M and front PWB (YC11) Front PWB (YC2) and engine PWB (YC10) Different type of the developer unit is installed. Install the correct developer unit. |
Error code: | 7404 |
Description: | Developer unit Y type mismatch error Absence of the developer unit Y is detected. |
Causes: | Defective connector cable or poor contact in the connector. Different type of the developer unit is installed. |
Remedy: | Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit Y and front PWB (YC15) Front PWB (YC2) and engine PWB (YC10) Different type of the developer unit is installed. Install the correct developer unit. |
Error code: | 7411 |
Description: | Drum unit type mismatch error Improper adaptation of the machine and developer unit is detected. |
Causes: | Defective connector cable or poor contact in the connector. Different type of the drum unit is installed. |
Remedy: | Different type of the drum unit is installed. Install the drum unit of the correct type. Drum unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Drum unit and Front PWB (YC6) Front PWB (YC2) and Engine PWB (YC8) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. |
Error code: | 7412 |
Description: | Drum unit type Mismatch error (Cyan) Improper adaptation of the main unit and drum unit is detected. |
Causes: | Drum unit C |
Remedy: | Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB. |
Error code: | 7413 |
Description: | Drum unit type Mismatch error (Magenta) Improper adaptation of the main unit and drum unit is detected. |
Causes: | Drum unit M |
Remedy: | Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB. |
Error code: | 7414 |
Description: | Drum unit type Mismatch error (Yellow) Improper adaptation of the main unit and drum unit is detected. |
Causes: | Drum unit Y |
Remedy: | Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB. |
Error code: | 9500 ... 9520 |
Description: | Contact the Service Administrative Division. |
Remedy: | Contact the Service Administrative Division. |
Error code: | 9530 |
Description: | Machine No.backup error C |
Causes: | IPU PWB error |
Remedy: | Contact the Service Administrative Division. |
Error code: | F000 |
Description: | Communication error between the main unit and CPU |
Causes: | The panel cannot be detected since the CPU communication between the main PWB and the operation panel main PWB is unavailable. |
Remedy: | 1 Resetting the main power The communication between the main PWB and the operation panel main PWB is faulty. Remove the original and check the sensor. Next, turn off the power switch and main switch. Then, turn on the main switch and power switch when passing 5 seconds. 2 Checking the connection The connector is not properly connected. The wire or the SATA cable is faulty. Clean the terminal of the following SATA cable connector and the wire connectors and reconnect the connectors. If there is no continuity, replace the SATA cable or the wire. • Main PWB - Operation panel main PWB Wiring diagram 3 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. Executing U021 4 Replacing the main PWB The main PWB is faulty. Replace the main PWB. 5 Replacing the operation panel main PWB The operation panel main PWB is faulty. Replace the panel main PWB. |
Error code: | F010 |
Description: | Program read error (SSD) |
Causes: | The garbled 2bit data was detected during the program read from the flash memory. |
Remedy: | 1 (When the service call error appears after replacing the SSD) Replacing the SSD along the correct procedures The firmware is not stored in the SSD. Insert the USB memory device containing all released firmware into the main unit, and turn the main power on. Firmware Update 2 Checking the SSD (if lit after replacing the SSD) An SSD out of specification is installed. Install the SSD matching the memory capacity specification. 3 Resetting the main power The communication between the main PWB and the operation panel main PWB is faulty. Remove the original and check the sensor. Next, turn off the power switch and main switch. Then, turn on the main switch and power switch when passing 5 seconds. 4 Checking the SSD The SSD is not properly attached. Check if the SSD terminal is not faulty and clean it. Then, reinstall the SSD. 5 Checking the connection The connector is not properly connected. The wire or the SATA cable is faulty. Clean the terminal of the following SATA cable connector and the wire connectors and reconnect the connectors. If there is no continuity, replace the SATA cable or the wire. • Main PWB - Operation panel main PWB Wiring diagram 6 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. Executing U021 7 Replacing the SSD The SSD is faulty. Backup the data in the SSD at U026. Then, replace the SSD and turn the main power on while installing the USB memory storing the firmware for the affected model n the main unit. 8 Replacing the main PWB The main PWB is faulty. Replace the main PWB. |
Error code: | F020 |
Description: | System memory error (RAM reading/writing error or CPU memory error) |
Causes: | The error appears during the reading/writing check of the RAM for the CPU when the main unit starts up. |
Remedy: | 1 Resetting the main power The communication between the main PWB and the operation panel main PWB is faulty. Remove the original and check the sensor. Next, turn off the power switch and main switch. Then, turn on the main switch and power switch when passing 5 seconds. 2 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. Executing U021 3 Checking the main PWB The connector or the FFC is not properly connected. The wire, the FFC or the PWB is faulty. Clean the connectors on the main PWB and the FFC terminal. Then, reconnect the wire connector and the FFC. At that time, if the wire is pinched by other parts or it is damaged, repair or replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. If the issue is not resolved, replace the main PWB. |
Error code: | F040 |
Description: | Option installation error |
Causes: | The size of the attached main memory is 2 GB when the DSDF is installed. |
Remedy: | Main memory Replace the main memory with a 4 GB one. DSDF • Remove the DSDF. • Replace the DSDF with an RADF. |
Error code: | F041 |
Description: | Over than available setting number tray detection error |
Causes: | Over than available setting number tray is installed. |
Remedy: | Remove the available setting number tray. |
Error code: | F050 |
Description: | Engine main program error |
Causes: | The engine program cannot start up. |
Remedy: | 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 2 Resetting the main power The print engine ROM checksum is faulty. Remove the original and check the sensor. Next, turn off the power switch and main switch. Then, turn on the main switch and power switch when passing 5 seconds. 3 Checking the EEPROM The EEPROM is not properly attached. Reattach the EEPROM. 4 Checking the engine PWB The connector or the FFC is not properly connected. The wire, the FFC or the PWB is faulty. Clean the connectors on the engine PWB and the FFC terminal. Then, reconnect the wire connector and the FFC. At that time, if the wire is pinched by other parts or it is damaged, repair or replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. If the issue is not resolved, replace the engine PWB. |
Error code: | F051 |
Description: | Scanner engine program error |
Causes: | The scanner program cannot start up |
Remedy: | 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 2 Resetting the main power The scanner engine RAM checksum is faulty. Remove the original and check the sensor. Next, turn off the power switch and main switch. Then, turn on the main switch and power switch when passing 5 seconds. 3 Checking the SSD The SSD is not properly attached. Reattach the SSD. 4 Checking the engine PWB The connector or the FFC is not properly connected. The wire, the FFC or the PWB is faulty. Clean the connectors on the engine PWB and the FFC terminal. Then, reconnect the wire connector and the FFC. At that time, if the wire is pinched by other parts or it is damaged, repair or replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. If the issue is not resolved, replace the engine PWB. |
Error code: | F278 |
Description: | Secondary power source error |
Causes: | The operation became unstable since the primary supply power dropped out temporarily and recovered. |
Remedy: | 1 Resetting the main power The power reset was performed immediately. Remove the original and check the sensor. Next, turn off the power switch and main switch. Then, turn on the main switch and power switch when passing 5 seconds. 2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the connectors on the LVU and reinsert the wire connectors. If there is no continuity, replace the wire. 3 Replacing the LVU The LVU is faulty. Replace the LVU. |
Название
Kyocera Блок фотобарабана
Kyocera Блок проявки голубой /Developer Unit C/
Kyocera Блок проявки черный /Developer Unit K/
Kyocera Блок проявки пурпурный /Developer Unit M/
Kyocera Блок проявки желтый /Developer Unit Y/
Kyocera Узел термозакрепления 230v
Kyocera Сервисный комплект
Kyocera Тонер-картридж голубой
Kyocera Тонер-картридж черный
Kyocera Тонер-картридж пурпурный
Kyocera Тонер-картридж желтый