Error code: | SC302 |
Description: | AC charge output error 3: C An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times). |
Causes: | This SC is issued if the BICU detects a short in the power pack 10 times consecutively. Open circuit (+) / Short circuit (-) |
Remedy: | • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU. |
Error code: | SC306 |
Description: | Charge Corona Wire Cleaner Error 2 The cleaning pad of the charge corona wire cleaner mechanism failed to return to its home position. |
Causes: | Connectors between motor and IOB loose, broken, defective • Charge wire dirty, defective, broken • Wire cleaning pad defective • Motor or motor board in motor unit defective |
Error code: | SC320 |
Description: | Development power pack error 1: K An interrupt checks the status of the each power pack every 2 ms. This SC is issued if the BICU detects a short in the development DC charge for black, magenta, cyan, or yellow (or V = 0) for 500 ms (250 times). |
Causes: | • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective |
Remedy: | • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective 1. Disconnect the high voltage cable from Terminal B of the high-voltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is "0" or nearly "0", check the high-voltage harness for defects and replace it if necessary. If replacing the harness does not solve the problem, 4. Test the resistance between the development unit terminal and the ground. If there is no resistance (0Ù) between the development unit and the ground, replace the development unit. 5. If there is no development PWM signal, replace the harness and/or IOB. |
Error code: | SC322 |
Description: | Development power pack error 3: C An interrupt checks the status of the each power pack every 2 ms. This SC is issued if the BICU detects a short in the development DC charge for black, magenta, cyan, or yellow (or V = 0) for 500 ms (250 times). |
Causes: | • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective |
Remedy: | • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective 1. Disconnect the high voltage cable from Terminal B of the high-voltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is "0" or nearly "0", check the high-voltage harness for defects and replace it if necessary. If replacing the harness does not solve the problem, 4. Test the resistance between the development unit terminal and the ground. If there is no resistance (0Ù) between the development unit and the ground, replace the development unit. 5. If there is no development PWM signal, replace the harness and/or IOB. |
Error code: | SC324 |
Description: | Development motor error 1: K The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the development motor of the affected color. |
Causes: | • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective |
Remedy: | • Development motor shaft locked, blocked by and obstruction • DRB (Drive Board) defective |
Error code: | SC390 |
Description: | TD sensor error 2 The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively during copying. Note: If the fax option is installed, this SC is issued immediately. If the fax option is not installed, this SC is issued after the prescribed number of pages is copied. |
Causes: | • TD sensor abnormal • Poor connection of the TD sensor harness |
Remedy: | • Replace the TD sensor. • Replace the harness of the TD sensor. |
Error code: | SC500 |
Description: | Transport/Fusing Motor Error The LOCK signal error is detected when the EGB monitors the transport/fusing motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.) |
Causes: | • Disconnected or defective motor harness. • Motor slips due to excessive load |
Remedy: | 1. Check the harness from the transport/fusing motor. Replace it if necessary. |
Error code: | SC503 |
Description: | Tray 1 feed error • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. • When the tray lowers, the tray lift sensor does not go off within 1.5 sec. |
Causes: | • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle |
Remedy: | • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle |
Error code: | SC504 |
Description: | Tray 2 feed error • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. • When the tray lowers, the tray lift sensor does not go off within 1.5 sec. |
Causes: | • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle |
Remedy: | • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle |
Error code: | SC506 |
Description: | Tandem tray back fence motor error. The back fence should be closed but the fence was not detected in the closed position within 500 ms. -or- The back fence should be open but the fence was not detected in the open within 500 ms. |
Causes: | The tray lift motor, pick-up solenoid, lift sensor, or lower limit sensor did not operate correctly. |
Remedy: | • Paper loaded incorrectly • Back fence motor harness disconnected, loose, defective • Back fence motor defective • Paper blocking sensors • Paper stuck between tray and motor • Back fence close, back fence open sensor harnesses disconnected, loose, or defective. • Back fence close, back fence open sensor defective • Paper or other obstacle is interfering with movement of the fence |
Error code: | SC507 |
Description: | Tandem Tray Rear Fence Motor Error (1st Tray) |
Causes: | One of the following occurred: • The return sensor does not switch on within 10 sec. after the rear fence motor switches on. • The HP sensor does not switch on 10 sec. after the rear fence motor switches on. • The HP sensor and return sensor switch on at the same time. |
Remedy: | • Rear fence motor harness disconnected or broken • Paper or other obstacle interfering with operation of the sensors • Paper or other obstacle trapped between tray and motor • Motor mechanical overload due to obstruction • Return sensor or HP sensor harness disconnected or broken • Return sensor or HP sensor dirty • Rear fence motor defective • Return sensor or HP sensor defective |
Error code: | SC542 |
Description: | Heating roller thermistor 1 error 2: No warmup. After the main switch is turned ON or the cover is closed, the heating roller temperature does not reach the ready temperature within 2 sec. after the heater switches ON. -or- If the roller was below 45°C, the heating roller did not reach the ready temperature 2 sec. after reaching 45°C. Note: Thermistor 2 stops monitoring the temperature once Thermistor 1 detects ready temperature. |
Causes: | • Defective thermistor • Incorrect power supply input at the main power socket • Defective fusing lamp |
Remedy: | • Thermistor is bent, installed incorrectly • Defective heating roller thermistor • Heating roller fusing lamp broken Do SP5810 to cancel the SC fusing code. |
Error code: | SC543 |
Description: | Heating roller thermistor 1 error 3: Software - High temperature. The thermistor detected a temperature over 230°C. |
Causes: | • Defective I/O control (EGB) • Defective EGB |
Remedy: | • TRIAC short • IOB defective • BICU defective • Fusing temperature out of control Do SP5810 to cancel the SC fusing code. |
Error code: | SC544 |
Description: | Heating roller thermistor 1 error 4: Hardware - High temperature. The thermistor detected a temperature over 260°C. |
Causes: | The machine detected the CPU port LOW twice at 100 ms intervals and issued this SC. This check is always done to check for overheating, even if SC543 does not detect the problem. |
Remedy: | • TRIAC short • IOB defective • BICU defective • Fusing temperature control is erratic Do SP5810 to cancel the SC fusing code. |
Error code: | SC547 |
Description: | Zero cross error. When the main switch is turned ON, the machine checks how many zero-cross signals are generated within 500 ms. This SC code is issued if the number of zerocross signals detected is either more than 66 or less than 45 for 10 readings. Note: Zero cross signals, generated from an ac power supply, are used to generate a trigger pulses to control the applied power accurately. |
Causes: | Defective fusing lamp relay |
Remedy: | • Electrical noise on the power supply line • Fusing relay damaged: replace the PSU. Normally, this SC is cancelled if you do SP5810 to cancel the SC fusing code. |
Error code: | SC696 |
Description: | Communication error between finisher and BECU (optional finisher only) -Definition- [B] The BECU board cannot communicate with the finisher properly. |
Causes: | · Poor connection of the interface cable for the finisher · BECU board defective · Finisher drive board defective |
Error code: | SC700 |
Description: | SPDF DF3100 (D3B0) Error SC700-01 ADF bottom plate lift motor error SC700-02 ADF pick-up roller lift motor SC700-04 ADF feed motor error SC700-05 ADF entrance motor error SC700-06 ADF transport motor error SC700-07 ADF scanning motor error SC700-09 ADF exit motor error -01 Even if the base plate motor is rotated in the base plate ascent direction, the base plate paper feed correct position sensor does not detect. Even if the base plate motor is rotated in the base plate descent direction, the base plate home position sensor does not detect. -02 Even if the pickup arm motor is rotated, the pickup arm home position sensor does not detect. -04, 05, 06, 07, 09 When an error notification signal is detected during the motor drive period. |
Causes: | -01 • Base plate paper feed correct position sensor error (output error) • Base plate home position sensor error (output error) • Base plate motor error (does not rotate) • Controller error -02 • Pick-up home position sensor error (output error) • Pick-up motor error (does not rotate) • Controller error -04, 05, 06, 07, 09 • Motor defective • Connector disconnected • Harness broken • Overload |
Remedy: | Check if the SC occurs by turning the main power OFF then ON, opening/closing covers, and input/output check. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step. The target parts that need to be checked are as follows; • -01: all motors, and Pick-up Roller HP Sensor • -02: all motors, and Bottom Plate Lift Sensor, Bottom Plate HP Sensor • -03, 04, 05, 06, 07, 09: all parts in ADF. 1. Check if the connector of the target part is connected securely. Reconnect the connector if it is disconnected, or loose. 2. Check the harness for the target part. Replace the harness if it is disconnected, or damaged. 3. Check if the motor runs, sensors turn OFF/ON, has no overloads, and is properly driven. Replace the parts if there are any defects. 4. Check if there are any signs of a short circuit. Replace the parts if there are any defects. |
Error code: | SC701 |
Description: | Original pick-up operation error. Even though the pick-up motor is rotating clock-wise, the pick-up roller home position sensor cannot detect the position of the pickup roller. |
Causes: | Even though the pickup motor is rotating clock-wise, the pickup roller home position sensor cannot detect the position of the pickup roller. |
Remedy: | • Pick-up roller HP sensor harness loose, disconnected, defective • Pick-up roller HP sensor defective • Pick-up motor harness loose, disconnected, defective • Pick-up motor defective • ARDF control board defective |
Error code: | SC702 |
Description: | ADF Feed-In Motor Error While the feed motor is operating, the encoder pulse signal is not received within the specified time, or the paper size length encoder signal cannot be detected within the specified time (the encoder is built into the feed-in motor). |
Causes: | • Feed-in motor connector, harness loose, broken, defective • Paper length sensor connector, harness loose, broken, defective • Feed-in motor defective • Paper length sensor or encoder is defective • ADF main control board defective |
Error code: | SC703 |
Description: | ADF Transport Belt Motor Error While the motor is operating, the encoder pulse signal is not received within the specified time and the transport belt motor does not turn properly. |
Causes: | • Transport belt motor defective • Poor connection between the transport motor and ADF main board • ADF main board defective |
Error code: | SC800 |
Description: | Communication error between 4-bin mailbox and BECU (optional 4- bin mailbox only) -Definition- [B] The BECU board cannot communicate with the 4-bin mailbox properly. |
Causes: | · Poor connection of the interface connector for the 4-bin mailbox · BECU board defective · 4-bin mailbox main control board defective |