Canon imageCLASS LBP324x
Рейтинг
Модули
INTERNAL COMPONENTS 2
EXTERNAL COVERS, PANELS, ETC.
MAIN CONTROLLER PCB ASSEMBLY
INTERNAL COMPONENTS 4
INTERNAL COMPONENTS 1
INTERNAL COMPONENTS 3
Детали MAIN CONTROLLER PCB ASSEMBLY
Деталь: | FIXING ASSY (220-240V) |
Парткод: | FM1-W154-000 |
Деталь: | CASSETTE ASSY |
Парткод: | FM1-N488-000 |
Деталь: | LABEL, CST. PAPER SIZE |
Парткод: | FU2-1855-000 |
Деталь: | MAIN MOTOR ASSY |
Парткод: | RM2-8684-000 |
Деталь: | BACK END LIMIT ASSEMBLY |
Парткод: | RM2-5746-000 |
Деталь: | LEVER, SWITCH |
Парткод: | FE8-0847-000 |
Деталь: | CABLE, USB INTERFACE |
Парткод: | FK4-4043-000 |
Деталь: | SWITCH PCB ASSY |
Парткод: | FM1-V946-000 |
Деталь: | CABLE, MAIN SWITCH |
Парткод: | FM1-X808-000 |
Деталь: | SCREW, TAP, M3X6 |
Парткод: | XA9-1503-000 |
Цена: | 340 ₽ |
Деталь: | SCREW, D, M3X6 |
Парткод: | XA9-1670-000 |
Деталь: | COVER, FULL DETECT SENSOR |
Парткод: | RC4-3219-000 |
Деталь: | FILM BIAS ASSY |
Парткод: | RM2-5689-000 |
Деталь: | PAPER RE-PICK UP CLUTCH ASSY |
Парткод: | RM2-8514-000 |
Деталь: | PAPER RE-PICK UP ASSY |
Парткод: | RM2-5666-000 |
Деталь: | SHEET |
Парткод: | RC4-3071-000 |
Деталь: | PAPER PICK-UP ROLLER ASSY |
Парткод: | RM2-5741 -000 |
Деталь: | SEPARATION ROLLER ASSY |
Парткод: | RM2-5745-000 |
Деталь: | TRAY, PAPER DELIVERY |
Парткод: | FE8-0822-000 |
Деталь: | BUSHING, M.P. COVER |
Парткод: | FE8-0827-000 |
Деталь: | COVER, RIGHT |
Парткод: | FE8-0829-000 |
Деталь: | COVER, WINDOW, RIGHT |
Парткод: | FE8-0867-000 |
Деталь: | CARTRIDGE DOOR ASSY |
Парткод: | FM1-N759-000 |
Деталь: | SHAFT, SUPPORT |
Парткод: | RC4-3002-000 |
Деталь: | LINK, PRESSURE RELEASE |
Парткод: | RC4-4479-000 |
Деталь: | TOP COVER ASSY |
Парткод: | FM1-N489-000 |
Деталь: | REAR DOOR ASSY |
Парткод: | FM1-N490-000 |
Деталь: | LEFT COVER ASSY |
Парткод: | FM1-N491 -000 |
Деталь: | OPERATION PANEL ASSY |
Парткод: | FM1-N496-000 |
Деталь: | LABEL, CASSETTE OPERATOR |
Парткод: | FU2-1858-000 |
Деталь: | LABEL, HIGH TMP. CAUTION |
Парткод: | FU2-1860-000 |
Деталь: | COVER, IOT |
Парткод: | FE8-0835-000 |
Деталь: | SCREW, TAP, M3X6 |
Парткод: | XA9-1503-000 |
Цена: | 340 ₽ |
Деталь: | MAIN CONTROLLER PCB ASSEMBLY |
Парткод: | FM2-J989-000 |
Деталь: | SCREW, FIXED |
Парткод: | FC5-7039-000 |
Деталь: | FIXING POWER SUPPLY PCB ASSY |
Парткод: | FM1-V987-000 |
Деталь: | L.V.POWER SUPPLY PCB ASSY |
Парткод: | FM1-V995-000 |
Деталь: | CABLE, LVPS |
Парткод: | FM1-X807-000 |
Деталь: | FAN |
Парткод: | RK2-1378-000 |
Деталь: | PAPER FEED DRIVE ASSY |
Парткод: | RM2-5715-000 |
Деталь: | SCREW, TAP, M3X6 |
Парткод: | XA9-1503-000 |
Цена: | 340 ₽ |
Деталь: | SCREW, W/WASHER, M3X8 |
Парткод: | XA9-1420-000 |
Цена: | 1 100 ₽ |
Деталь: | MICROSWITCH |
Парткод: | RK2-0534-000 |
Деталь: | FAN |
Парткод: | RK2-1378-000 |
Деталь: | CABLE, FLEXIBLE FLAT |
Парткод: | RK2-8657-000 |
Деталь: | CABLE, FLEXIBLE FLAT |
Парткод: | RK2-6260-000 |
Деталь: | H.V. POWER SUPPLY PCB ASSY |
Парткод: | RM3-7424-000 |
Деталь: | LASER SCANNER ASSY |
Парткод: | RM2-2891 -000 |
Деталь: | TAG CABLE ASSY |
Парткод: | RM2-2596-000 |
Деталь: | SCREW, W/WASHER, M3X8 |
Парткод: | XA9-1420-000 |
Цена: | 1 100 ₽ |
Деталь: | SCREW, D, M3X6 |
Парткод: | XA9-1670-000 |
Деталь: | LABEL, SAFETY MARK, GEAR |
Парткод: | FU2-2983-000 |
Деталь: | ROLLER, TRANSFER |
Парткод: | RM1-4023-000 |
Деталь: | HOLDER, TRANSFER ROLLER, RIGHT |
Парткод: | RC4-3133-000 |
Деталь: | HOLDER, TRANSFER ROLLER, LEFT |
Парткод: | RC4-3134-000 |
Деталь: | SCREW, D, M3X6 |
Парткод: | XA9-1670-000 |
Деталь: | SPRING, COMPRESSION |
Парткод: | RU8-2935-000 |
Деталь: | ROLLER, MULTI-PURPOSE |
Парткод: | RL2-0656-000 |
Деталь: | PAD, MULTI-PURPOSE SEPARATION |
Парткод: | RL2-0657-000 |
Деталь: | REGISTRATION ASSY |
Парткод: | FM1-N761-000 |
Деталь: | MULTI-PURPOSE GEAR ASSY |
Парткод: | RM2-5700-000 |
Деталь: | SOLENOID ASSY |
Парткод: | RM1-5421 -000 |
Деталь: | HINGE, CARTRIDGE DOOR, LEFT |
Парткод: | RC4-3010-000 |
Деталь: | DC CONTROLLER PCB ASSY |
Парткод: | FM2-M823-000 |
Деталь: | CABLE, FLEXIBLE FLAT |
Парткод: | FK4-4208-000 |
Коды ошибок
10-0100
10-0404
E000-0000
E001-0000
E004-0000
E004-0005
E014-0000
E014-0001
E015-0001
E015-0002
E015-0003
E015-0004
E066-0000
E06F-0068
E100-0000
E110-0000
E110-0001
E196-0000
E196-0002
E245-1011 ... E245-1023
E245-2012, E245-2022
E246-0001 ... E355-0003
E602-0001
E602-0002
E602-0003
E602-0006
E602-0007
E602-0008
E602-0009
E602-1102
E602-1112
E602-1113
E602-1302
E602-1312
E602-1313
E602-1602
E602-1612
E602-1613
E604-0000
E604-0001
E616-0001
E616-0002
E730-100A
E730-C000
E730-C001
E730-D000
E730-D001
E733-0001
E733-0004
E733-0006
E740-0002
E740-0004
E744-0800
E744-0900
E744-1000
E744-1100
E748-2012
E748-4000, E748-4020
E760-0000
E805-0001
E805-0002
E808-0001
E840-0000
Описание
Error code: | 10-0100 |
Description: | Unidentified Toner Cartridge replacement notification alarm (C) |
Causes: | Detail Code: 0184 |
Remedy: | When the replacement with a non-genuine Toner Cartridge was detected. |
Error code: | 10-0404 |
Description: | Toner Cartridge empty alarm (Bk) |
Causes: | Alarm to be generated once the Toner Cartridge becomes empty. |
Error code: | E000-0000 |
Description: | Startup error The temperature detected by the main or sub thermistor does not rise to the specified value during startup control. |
Causes: | The detection temperature of the main thermistor did not increase after start of the power distribution to the heater. |
Remedy: | - Check the fixing film connector. - Replace the fixing film unit. - Replace the DC controller PCB. |
Error code: | E001-0000 |
Description: | Abnormally high temperature (detected by main thermistor) The main thermistor detected an abnormally high temperature 235 deg C) during temperature control |
Causes: | The main thermistor detected a temperature of higher than 255 degree C. |
Remedy: | - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB. |
Error code: | E004-0000 |
Description: | Fixing power supply drive circuit error |
Causes: | 43 to 57Hz could not be detected continuously for more than 5 seconds when zero cross detection started. |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the DC Controller Board. (2) Replace the Fixing Assembly. |
Error code: | E004-0005 |
Description: | Fixing Relay fusion error |
Causes: | At power ON or recovery from sleep mode, a zero cross signal was detected three times during the period of 100 ms after completion of CPU initialization. |
Remedy: | 1. Check the harness/connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB. |
Error code: | E014-0000 |
Description: | Fixing motor failure |
Causes: | Fixing motor startup error The target speed was not reached within a specified time after startup of the motor. |
Remedy: | Check the contact of the connector between the fixing motor (J516) and the DC controller PCB (J81). Check the gear between the fixing motor and the fixing assembly. Replace the fixing motor. |
Error code: | E014-0001 |
Description: | Fixing motor failure |
Causes: | Fixing motor rotation error The motor rotated out of the target speed during rotation after the target speed was reached. |
Remedy: | Check the contact of the connector between the fixing motor (J516) and the DC controller PCB (J81). Check the gear between the fixing motor and the fixing assembly. Replace the fixing motor. |
Error code: | E015-0001 |
Description: | Cassette 1 lift up motor error |
Causes: | Cassette 1 lift up motor error |
Remedy: | Reconnect the connector J151 on the DC controller PCB and the relay connector J742. Check the cassette media stack surface sensor in the sensor monitor mode. If a failure is found, replace the lifter drive unit. Replace the lifter drive unit. |
Error code: | E015-0002 |
Description: | Cassette 2 lift up motor error |
Causes: | Cassette 2 lift up motor error |
Remedy: | Reconnect the connector J2003 on the paper feeder driver PCB and the relay connector J702. Check the paper feeder media stack surface sensor in the sensor monitor mode. If a failure is found, replace the pickup unit. Reconnect the connector J2006 on the paper feeder driver PCB. Replace the lifter drive unit. |
Error code: | E015-0003 |
Description: | Cassette 3 lift-up error |
Causes: | After lift-up of the Lifting Plate of the second casstte of the Paper Feeder started, ON status of the Paper Surface Sensor of the second casstte of the Paper Feeder was not detected within the specified period of time. |
Remedy: | 1. Turn ON the power with the cassette of the Paper Feeder removed, insert the cassette, and then check the operation sound of the Lifter Motor. When there is operation sound of the Lifter Motor, check if the Lifting Plate has been lifted up. <When the Lifting Plate has been lifted up> 1. Check the harness/connector between the Paper Feeder Controller PCB and the Paper Surface Sensor of the Paper Feeder. 2. Replace the Paper Feeder Controller PCB. 3. Replace the DC Controller PCB. <When the Lifting Plate has not been lifted up> 1. Check the condition of the gear of the Paper Feeder (missing teeth, swing). 2. Check the harness/connector between the Paper Feeder Controller PCB and the PF Lifter mater. 3. Replace the Drive Unit (included the Lifter Motor). <When there is no operation sound of the motor> 1. Check the harness/connector between the Paper Feeder Controller PCB and the PF Lifter Motor of the Paper Feeder Unit. 2. Replace the Cassette Feeder Controller PCB. 3. Replace the DC Controller PCB. |
Error code: | E015-0004 |
Description: | Cassette 4 lift-up error |
Causes: | After lift-up of the Lifting Plate of the third casstte of the Paper Feeder started, ON status of the Paper Surface Sensor of the third casstte of the Paper Feeder was not detected within the specified period of time. |
Remedy: | 1. Turn ON the power with the cassette of the Paper Feeder removed, insert the cassette, and then check the operation sound of the Lifter Motor. When there is operation sound of the Lifter Motor, check if the Lifting Plate has been lifted up. <When the Lifting Plate has been lifted up> 1. Check the harness/connector between the Paper Feeder Controller PCB and the Paper Surface Sensor of the Paper Feeder. 2. Replace the Paper Feeder Controller PCB. 3. Replace the DC Controller PCB. <When the Lifting Plate has not been lifted up> 1. Check the condition of the gear of the Paper Feeder (missing teeth, swing). 2. Check the harness/connector between the Paper Feeder Controller PCB and the PF Lifter mater. 3. Replace the Drive Unit (included the Lifter Motor). <When there is no operation sound of the motor> 1. Check the harness/connector between the Paper Feeder Controller PCB and the PF Lifter Motor of the Paper Feeder Unit. 2. Replace the Cassette Feeder Controller PCB. 3. Replace the DC Controller PCB. |
Error code: | E066-0000 |
Description: | Environment sensor failure |
Causes: | Environment sensor failure |
Remedy: | Replace the environment sensor. |
Error code: | E06F-0068 |
Description: | EEPROM access failure |
Causes: | EEPROM access failure |
Remedy: | Replace the EEPROM. |
Error code: | E100-0000 |
Description: | BD detection PCB failure The BD detection PCB is faulty. |
Causes: | Yellow optical assembly failure |
Remedy: | - Check the connector of the BD detection PCB. - Replace the laser scanner unit. - Replace the DC controller PCB. |
Error code: | E110-0000 |
Description: | Optical assembly error (Scanner motor) |
Causes: | Optical assembly error (Scanner motor initial operation failure) |
Remedy: | Check the contact of the connector between the laser scanner unit and the DC controller. Replace the laser scanner unit. |
Error code: | E110-0001 |
Description: | Optical assembly error (Scanner motor) |
Causes: | Optical assembly error (Scanner motor rotation failure) |
Remedy: | Check the contact of the connector between the laser scanner unit and the DC controller. Replace the laser scanner unit. |
Error code: | E196-0000 |
Description: | Invalid RFU execution requested |
Causes: | D-con update for the host machine or the optional cassette is not completed. |
Error code: | E196-0002 |
Description: | Image processor PCB failure Error on writing and readout ROM of image processor PCB (option ROM). |
Causes: | Can not access to DC controller NVRAM Cause Failure in DC controller PCB |
Remedy: | - Putting the switch on/off of the power supply. - Replace the image processor PCB. |
Error code: | E245-1011 ... E245-1023 |
Description: | Host machine FRAM write error |
Causes: | Host machine FRAM write error was detected. |
Remedy: | Replace the Main Controller PCB. |
Error code: | E245-2012, E245-2022 |
Description: | FLASH write error |
Causes: | FLASH write error was detected. |
Remedy: | Replace the Main Controller PCB. |
Error code: | E246-0001 ... E355-0003 |
Description: | System error |
Causes: | System error |
Remedy: | Contact the sales company. |
Error code: | E602-0001 |
Description: | HDD error |
Causes: | Lack of the HDD capacity The capacity of the HDD installed is smaller than that of the HDD used in the software. |
Error code: | E602-0002 |
Description: | HDD error |
Causes: | Bootable load failure A Bootable CD was not contained. A Bootable CD was damaged. |
Remedy: | Burn the Bootable CD again. |
Error code: | E602-0003 |
Description: | HDD error |
Causes: | HDD access error An error occurred caused by the device or hardware when accessing to the HDD during execution of bootrom. (Damage to the sector / Busy device status, etc.) |
Remedy: | Turn on the power again. |
Error code: | E602-0006 |
Description: | HDD error |
Causes: | SubBootable load failure A SubBootable CD was not contained. A SubBootable CD was damaged. |
Remedy: | Burn the SubBootable CD again. |
Error code: | E602-0007 |
Description: | HDD error |
Causes: | The contents (ICC-Profile, etc.) could not be detected. (The contents were not contained. The contents were damaged, etc.) |
Remedy: | Burn the Bootable CD again. |
Error code: | E602-0008 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Alternative block of flash memory is almost depleted. |
Remedy: | Perform the following procedure to replace the the Main Controller PCB and export/import user information. 1. Export user information from the flash memory of the old Main Controller PCB (before replacement). 2. Replace the Main Controller PCB. Import user information to the flash memory of the new Main Controller PCB (after replacement). |
Error code: | E602-0009 |
Description: | MEAP cannot be started. |
Causes: | MEAP cannot be started due to an error caused by invalid power down. |
Remedy: | 1. Select Function.gr > MEAP > MEAP FUNCTION = ON, and turn OFF and then ON the main power. * Since the installed MEAP application and its management information are all cleared after reboot, MEAP needs to be reinstalled. |
Error code: | E602-1102 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Error detection of file system (LBP7680Cx only) |
Remedy: | Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. If E616-0001 occurs at restart after turning OFF and then ON the power, execute the following procedures. 1. Initialize MEAP area, and install MEAP application again. (Refer to the remedy for E616-0001.) 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1112 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Device access error (LBP7680Cx only) |
Remedy: | Execute the following procedures. If E616- 0001 occurs after turning OFF and then ON the power (procedure 1), install MEAP application again by following the remedy for E616-0001 first. Then, execute the procedure 2. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1113 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Device access error (LBP7680Cx only) |
Remedy: | Execute the following procedures. If E616- 0001 occurs after turning OFF and then ON the power (procedure 1), install MEAP application again by following the remedy for E616-0001 first. Then, execute the procedure 2. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1302 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | File system initialization error (LBP7680Cx only) |
Remedy: | Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1312 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Device access error (LBP7680Cx only) |
Remedy: | Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1313 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Device access error (LBP7680Cx only) |
Remedy: | Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1602 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | File system initialization error (LBP7680Cx only) |
Remedy: | Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1612 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Device access error (LBP7680Cx only) |
Remedy: | Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E602-1613 |
Description: | E602-1102 to 1613 Only LBP7680Cx is supported. |
Causes: | Device access error (LBP7680Cx only) |
Remedy: | Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. |
Error code: | E604-0000 |
Description: | Memory error |
Causes: | Lack of memory capacity |
Remedy: | Check the memory capacity inserted to each slot. |
Error code: | E604-0001 |
Description: | Insufficient memory capacity |
Causes: | Failed to allocate the memory required to start PDL. |
Remedy: | - Remove and then install the additional memory. - Replace the additional memory with a correct one. - Turn OFF and then ON the power. - Replace the Controller PCB. |
Error code: | E616-0001 |
Description: | (LBP7680Cx only) |
Causes: | MEAP application was deleted by auto recovery at restart after E602-11XX. |
Remedy: | Initialize MEAP area in the flash memory with the following procedures, and install MEAP application again. 1. Initialize the MEAP area. Service Mode > FUNCTION GR. > MEAP > MEAP FUNCTION > ON 2. Install MEAP application again. |
Error code: | E616-0002 |
Description: | System error |
Causes: | System error |
Remedy: | 1. Execute Setup > Initialize Menu to initialize NVRAM. |
Error code: | E730-100A |
Description: | Printer service call |
Error code: | E730-C000 |
Description: | An error such as memory not acquired at initialization occurred. |
Remedy: | Turn on the power again. |
Error code: | E730-C001 |
Description: | An error occurred when accessing the HDD. |
Remedy: | Turn on the power again. |
Error code: | E730-D000 |
Description: | Printer service call |
Causes: | An error, such as failure in memory retrieval at initialization, occurred. |
Remedy: | - Turn OFF and then ON the power. - Replace the Main Controller PCB. |
Error code: | E730-D001 |
Description: | Printer service call |
Causes: | Printer communication error (communication error at initial communication and negotiation packet error) |
Remedy: | Only LBP7680Cx is supported. |
Error code: | E733-0001 |
Description: | Printer communication error (Invalid communication after communication is established, Parity error) |
Remedy: | Turn on the power again. Replace the DC controller PCB. |
Error code: | E733-0004 |
Description: | Printer communication error (Undefined command error) |
Remedy: | Turn on the power again. Replace the DC controller PCB. |
Error code: | E733-0006 |
Description: | Printer communication error (Unknown communication error) |
Remedy: | Turn on the power again. Replace the DC controller PCB. |
Error code: | E740-0002 |
Description: | Error detection on either Network Board or Mac address |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Check the connection of the network cable. (2) Replace the Main Controller Board. |
Error code: | E740-0004 |
Description: | LAN controller chip access error |
Remedy: | 1.Check the area around the LAN chip. 2.Replace the board. |
Error code: | E744-0800 |
Description: | Model code mismatch |
Remedy: | Replace Soft-ID PCB. |
Error code: | E744-0900 |
Description: | Model code mismatch |
Remedy: | Change to proper bootable |
Error code: | E744-1000 |
Description: | Mismatch of the series or model of the firmware sent at the time of downloading |
Remedy: | Check the supported series or model of the firmware, and burn the correct series or model of firmware. |
Error code: | E744-1100 |
Description: | Model code mismatch |
Causes: | Detection of falsification of the Controller Board |
Remedy: | - Turn OFF and then ON the power. - Replace the Main Controller PCB. |
Error code: | E748-2012 |
Description: | Failed to rewrite due to no more alternative block of Flash ROM (NAND) available. |
Error code: | E748-4000, E748-4020 |
Description: | System error |
Causes: | System error |
Remedy: | 1. Turn OFF and then ON the power. 2. Replace the Main Controller PCB. |
Error code: | E760-0000 |
Description: | CPU exception occurred. |
Remedy: | Turn on the power again. |
Error code: | E805-0001 |
Description: | Error in duplex cooling fan |
Causes: | Fan 1 failure |
Error code: | E805-0002 |
Description: | Fan Motor 2 error |
Causes: | The Sub Fan fails to rotate at the specified rotation speed. |
Remedy: | 1. Check the connection of the Sub Fan. 2. Replace the Sub Fan. |
Error code: | E808-0001 |
Description: | Fixing Assembly_Edge Left Cooling Fan error |
Remedy: | When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the Edge Left Cooling Fan. (2) Replace the DC Controller Board. |
Error code: | E840-0000 |
Description: | Pressure release mechanism failure |
Causes: | The target pressure position was not reached even when 3.5 seconds (approximately 1.5 rotation of the cam) elapsed after start of the fixing motor reverse rotation. |
Remedy: | Check the gears and detection flags related to fixing pressure release mechanism. Replace the fixing pressure release sensor (PS9). Replace the fixing motor. Replace the fixing assembly. |