Toshiba e-Studio 2306
Рейтинг
Модули
EXIT-ASY
SUPPLIES
DEVELOPER-1-ASY
BYPASS-ASY
ADU-2-ASY
DEVELOPER-2-ASY
JIGS & GREASE
MAIN-DRIVE-ASY
PLATEN-ASY
REPLACE UNIT
FUSER-2-ASY
COVER-ASY
ADU-1-ASY
FRONT-FRAME-ASY
MAIN-CHARGER-ASY
GUIDE-ASY
OPTICAL-ASY
STAY-ASY
PM-KIT
BASE-FRAME-ASY
DRAWER-ASY
REAR-FRAME-ASY
FUSER-1-ASY
CONTROL-PANEL-ASY
Детали BASE-FRAME-ASY
Деталь: | COV-EXIT-U-H24X |
Парткод: | 6LJ77737000 |
Деталь: | SFT-EXIT-IDLE-280 |
Парткод: | 6LE58600000 |
Деталь: | GEAR-10S26-RLR-EXIT |
Парткод: | 6LJ77100000 |
Деталь: | RLR-EXIT-L-EX |
Парткод: | 6LJ02514000 |
Деталь: | ROLLER-EXIT-280 |
Парткод: | 6LH23930000 |
Деталь: | STOP-RING-6-5 |
Парткод: | 4407972860 |
Деталь: | SPG-C-ROLL-EXIT |
Парткод: | 6LJ57809000 |
Деталь: | SPG-EXIT-FUS-H24X |
Парткод: | 6LJ77101000 |
Деталь: | BUSH-6-BCF-050 |
Парткод: | 6LJ55543000 |
Деталь: | BUSH-6-POM |
Парткод: | 44201492000 |
Деталь: | RR/E-5-SS |
Парткод: | X0-00966000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | SPG-EARTH-EXIT-BRS-H24X |
Парткод: | 6LJ77104000 |
Деталь: | D-2505 |
Парткод: | 6LJ83445000 |
Деталь: | GQ-1131 |
Парткод: | 6A000001575 |
Деталь: | KK-2505 |
Парткод: | 6AG00005087 |
Деталь: | OD-2505 |
Парткод: | 6LJ83358000 |
Деталь: | OD-2505C |
Парткод: | 6LJ83358100 |
Деталь: | PS-ZT2507D(1) |
Парткод: | 6AG00004872 |
Деталь: | PS-ZT2507T(1) |
Парткод: | 6AG00004874 |
Деталь: | PS-ZT2507TS(1) |
Парткод: | 6AG00004875 |
Деталь: | PS-ZT2507E(1) |
Парткод: | 6AG00005086 |
Деталь: | PS-ZT2507U(1) |
Парткод: | 6AG00005073 |
Деталь: | PS-ZT2507A(1) |
Парткод: | 6AG00005074 |
Деталь: | PS-ZT2507P(1) |
Парткод: | 6AG00005075 |
Деталь: | PS-ZT2507PS(1) |
Парткод: | 6AG00005076 |
Деталь: | PS-ZT2507C(1) |
Парткод: | 6AG00005077 |
Деталь: | PS-ZT2507CS(1) |
Парткод: | 6AG00005078 |
Деталь: | PS-ZT2507C(12) |
Парткод: | 6AG00005079 |
Деталь: | PS-ZT2507CS(12) |
Парткод: | 6AG00005080 |
Деталь: | MF-2505U |
Парткод: | 6AG00004869 |
Деталь: | MF-2505E |
Парткод: | 6AG00004870 |
Деталь: | KA-2507PC |
Парткод: | 6AG00005057 |
Деталь: | KA-2507PC-C |
Парткод: | 6AG00005058 |
Деталь: | GN-1080 |
Парткод: | 6AG00005070 |
Деталь: | GN-1080C |
Парткод: | 6AG00005072 |
Деталь: | FRAME-CLN-CR-H24X |
Парткод: | 6LJ75500000 |
Деталь: | SEAL-CLN-FRT-P |
Парткод: | 6LJ75532000 |
Деталь: | SEAL-CLN-RER-P |
Парткод: | 6LJ75533000 |
Деталь: | SEAL-BLADE-SIDE |
Парткод: | 6LA79547000 |
Деталь: | SEAL-CLN-C-H24X |
Парткод: | 6LJ75521000 |
Деталь: | SHEET-BLADE-REC-H24X |
Парткод: | 6LJ75534000 |
Деталь: | FRAME-CLN-F-H24X |
Парткод: | 6LJ75502000 |
Деталь: | ASYS-AUGER-CLN |
Парткод: | 6LJ75529000 |
Деталь: | PLATE-DRV-TNR |
Парткод: | 6LJ75512000 |
Деталь: | COVER-RCYCL-H24X |
Парткод: | 6LJ75511000 |
Деталь: | BUSH-AUGER-F-H24X |
Парткод: | 6LJ75506000 |
Деталь: | S/TPP/BID-3X8-NI |
Парткод: | 6LA80090000 |
Деталь: | BUSH-4-671 |
Парткод: | 6LJ75536000 |
Деталь: | GEAR-AUG |
Парткод: | 6LJ75516000 |
Деталь: | GEAR-AUG-IDLE |
Парткод: | 6LJ75517000 |
Деталь: | WHEEL-CLN-8 |
Парткод: | 41306325000 |
Деталь: | SCRAPER-371 |
Парткод: | 6LA79618000 |
Деталь: | SPA-SCRPR-DRUM-H24X |
Парткод: | 6LJ75525000 |
Деталь: | BL-2320D |
Парткод: | 6LA27845000 |
Деталь: | SFT-DRUM-H24X |
Парткод: | 6LJ75515000 |
Деталь: | HLDR-JOINT-R-H24X |
Парткод: | 6LJ75514000 |
Деталь: | HLDR-JOINT-F-H24X |
Парткод: | 6LJ75513000 |
Деталь: | BRKT-CLN |
Парткод: | 6LJ75531000 |
Деталь: | S/TPS/FHEXM/R-3X6-ZU3 |
Парткод: | X0-02419000 |
Деталь: | SHEET-RCYCL-SLIDE_MB |
Парткод: | 6LJ75535000 |
Деталь: | RF_MB-JOINT-DEV |
Парткод: | 6LJ76568000 |
Деталь: | OD-2505 |
Парткод: | 6LJ83358000 |
Деталь: | OD-2505C |
Парткод: | 6LJ83358100 |
Деталь: | TRAY-SFB-U-241 |
Парткод: | 6LH51457200 |
Деталь: | GUIDE-TRAY-SFB-241F |
Парткод: | 6LH51406100 |
Деталь: | GUIDE-TRAY-SFB-241R |
Парткод: | 6LH51405100 |
Деталь: | GEAR-10S18-6-BYP-TRAY |
Парткод: | 6LE53504000 |
Деталь: | TRAY-SFB-241L |
Парткод: | 6LH51458100 |
Деталь: | TRAY-SFB-SB241 |
Парткод: | 6LH51404100 |
Деталь: | LINK-P-TRAY |
Парткод: | 6LH51416000 |
Деталь: | LVR-P-TRAY-16X |
Парткод: | 6LH51417100 |
Деталь: | LBL-HIGH-TRAY-H16X |
Парткод: | 6LJ11400000 |
Деталь: | LBL-INFO-SFB-H16X |
Парткод: | 6LJ18017000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | STOPPER-TRAY-BYP-H241 |
Парткод: | 6LJ74936000 |
Деталь: | SHEET-GUIDE-PAD-F-T05 |
Парткод: | 6LH51450000 |
Деталь: | S/TPP/BID-3X8-NI |
Парткод: | 6LA80090000 |
Деталь: | GUIDE-SUB-241F |
Парткод: | 6LH51410100 |
Деталь: | GUIDE-SUB-241R |
Парткод: | 6LH51409100 |
Деталь: | HOLDER-PWA-SFB |
Парткод: | 6LH51408000 |
Деталь: | LVR-GUIDE-SFB-16X |
Парткод: | 6LH51411100 |
Деталь: | SPL-LVR-SFB |
Парткод: | 6LH51415000 |
Деталь: | CASE-DUCT-R-H24X |
Парткод: | 6LJ80201000 |
Деталь: | ASYS-FAN-DUCT-H24X |
Парткод: | 6LJ80220000 |
Деталь: | FILTER-OZONE-H24X |
Парткод: | 6LJ80213000 |
Деталь: | COVER-DUCT-R-H24X |
Парткод: | 6LJ80202000 |
Деталь: | SPG-PUSH-TR-H24X |
Парткод: | 6LJ80211000 |
Деталь: | CASE-RLR-TR-H24X |
Парткод: | 6LJ80225000 |
Деталь: | CH-SEP-H24X |
Парткод: | 6LJ80224000 |
Деталь: | SHEET-CH-SEP-30-H24X |
Парткод: | 6LJ80223000 |
Деталь: | SPG-RLR-TRU-H24X |
Парткод: | 6LJ80207000 |
Деталь: | SPG-CH-SEP-H24X |
Парткод: | 6LJ80208000 |
Деталь: | CR-2505TR |
Парткод: | 6LJ83407000 |
Деталь: | BUSH-6-POM |
Парткод: | 44201492000 |
Деталь: | GEAR-RLR-TR-H24X |
Парткод: | 6LJ80205000 |
Деталь: | SPC-PUSH-RGST |
Парткод: | 6LE62403000 |
Деталь: | PUSH-RGST-470-V |
Парткод: | 6LH56317000 |
Деталь: | ROLLER-RGST-R-H24X |
Парткод: | 6LJ79503000 |
Деталь: | GEAR-10S16-8 |
Парткод: | 6LJ79504000 |
Деталь: | WSHR-82X19-048-ABS |
Парткод: | 6LJ14900000 |
Деталь: | PLATE-RGST-H24X |
Парткод: | 6LJ77407000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | SHEET-RGST-R |
Парткод: | 6LJ77410000 |
Деталь: | ASYS-CASE-DEV-24X |
Парткод: | 6LJ76544000 |
Деталь: | SEAL-VC6-10-2.5 |
Парткод: | 4401949290 |
Деталь: | ASYS-MIXER-2-24X |
Парткод: | 6LJ76546000 |
Деталь: | MIXER-1-24X |
Парткод: | 6LJ76503000 |
Деталь: | BUSH-DEV-FRT-24X |
Парткод: | 6LJ76509000 |
Деталь: | BUSH-6X12X4R8F-671 |
Парткод: | 6LJ76517000 |
Деталь: | GEAR-MIXER-AGIR |
Парткод: | 6LJ76512000 |
Деталь: | GEAR-MIXER-SPLR |
Парткод: | 6LJ76513000 |
Деталь: | GEAR-DEV-IDLER |
Парткод: | 6LJ76514000 |
Деталь: | GEAR-RLR-MAGT |
Парткод: | 6LJ76515000 |
Деталь: | RLR-MAGT-24X |
Парткод: | 6LJ76500000 |
Деталь: | BUSH-RLR-MAGT-FRT |
Парткод: | 6LJ76516000 |
Деталь: | ASYS-HLDR-GEAR |
Парткод: | 6LJ76553000 |
Деталь: | SPG-F-BIAS-DEV |
Парткод: | 6LJ76523000 |
Деталь: | ADJSTR-MAGT |
Парткод: | 6LJ76552000 |
Деталь: | S/BID-M3X4-NI |
Парткод: | X0-00426000 |
Деталь: | ASYS-DOCTOR-DEV-24X-K |
Парткод: | 6LJ76565000 |
Деталь: | SPG-C-5XR6X12R5 |
Парткод: | 6LJ76555000 |
Деталь: | SNSR-ATC-240 |
Парткод: | 6LJ83116000 |
Деталь: | HLDR-CNTR-ATC |
Парткод: | 6LJ76551000 |
Деталь: | SEAL-CASE-DEV-DOC |
Парткод: | 6LJ76536000 |
Деталь: | SHEET-MAGT-SIDE-RER |
Парткод: | 6LJ76541000 |
Деталь: | SHEET-MAGT-SIDE-FRT |
Парткод: | 6LJ76540000 |
Деталь: | ASYS-COVER-DEV-FRT |
Парткод: | 6LJ76548000 |
Деталь: | ASYS-COVER-DEV-MAN |
Парткод: | 6LJ76547000 |
Деталь: | GUIDE-TRANS-FRONT |
Парткод: | 6LJ76505000 |
Деталь: | KEY-PLATE-280 |
Парткод: | 6LE65500000 |
Деталь: | BRUSH-33 |
Парткод: | 4407915710 |
Деталь: | ASM-SILICONE-1M |
Парткод: | 4407933080 |
Деталь: | OIL-LAUNA40-100 |
Парткод: | 4842512170 |
Деталь: | GREASE-HP300-S |
Парткод: | 6LA00019000 |
Деталь: | ASM-PG-ALV2 |
Парткод: | 41303711000 |
Деталь: | MOLYKOTE_EM-30L_100G |
Парткод: | 6LE36904000 |
Деталь: | ASM-PG-GE334C-S |
Парткод: | 41303710000 |
Деталь: | P-POWDER-PPT001 |
Парткод: | 4407015430 |
Деталь: | MOTR_D-MAIN-DRIVE-H24X |
Парткод: | 6LJ76800000 |
Деталь: | ASYS-COV-DRV-LWR-H241 |
Парткод: | 6LJ76861000 |
Деталь: | GEAR-05H61-05H32 |
Парткод: | 6LJ76801000 |
Деталь: | GEAR-05H57-05H28 |
Парткод: | 6LJ76804000 |
Деталь: | GEAR-05H54 |
Парткод: | 6LJ76802000 |
Деталь: | GEAR-08S26 |
Парткод: | 6LJ76803000 |
Деталь: | GEAR-08S24-08S21 |
Парткод: | 6LJ76812000 |
Деталь: | COUPL-GR-P-JOINT-H24X |
Парткод: | 6LJ76818000 |
Деталь: | GEAR-08S42-10S21 |
Парткод: | 6LJ76813000 |
Деталь: | GEAR-08S48-10S22 |
Парткод: | 6LJ76806000 |
Деталь: | GEAR-10S34-10S37 |
Парткод: | 6LJ76811000 |
Деталь: | GEAR-10S38 |
Парткод: | 6LJ76809000 |
Деталь: | GEAR-10S30 |
Парткод: | 6LJ76805000 |
Деталь: | SPG-GROUND-MAIN-MOT-H24X |
Парткод: | 6LJ76832000 |
Деталь: | STOP-RING-GEAR-H24X |
Парткод: | 6LJ76844000 |
Деталь: | S/FHEXM-M3X8-NI |
Парткод: | X0-02231000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | ASYS-COV-DRV-UPPER-H241 |
Парткод: | 6LJ76852000 |
Деталь: | GEAR-10S24 |
Парткод: | 6LJ76807000 |
Деталь: | GEAR-10S19-10S22 |
Парткод: | 6LJ76814000 |
Деталь: | GEAR-10S40-10S31 |
Парткод: | 6LJ76810000 |
Деталь: | GEAR-10S20-DRV-FUS-2 |
Парткод: | 6LJ76819000 |
Деталь: | GEAR-10S20-DRV-FUS-1 |
Парткод: | 6LJ76808000 |
Деталь: | CLUTCH-50C-G28-6 |
Парткод: | 6LH51224000 |
Деталь: | COVER-CLT-CST-H24X |
Парткод: | 6LJ76815000 |
Деталь: | COVER-MAIN-DRV-EXIT-H241 |
Парткод: | 6LJ76849000 |
Деталь: | GEAR-08S49-10S20 |
Парткод: | 6LJ76858000 |
Деталь: | GEAR-10S33 |
Парткод: | 6LJ76857000 |
Деталь: | HINGE-PLATEN-DR |
Парткод: | 6LJ78722000 |
Деталь: | SITPPIBID-4X14-NI |
Парткод: | X0-02091000 |
Деталь: | SHEET-PLATEN-DR |
Парткод: | 6LJ78723000 |
Деталь: | COVER-PLATEN-DR |
Парткод: | 6LJ78724000 |
Деталь: | MAIN-CH-2505 |
Парткод: | 6LJ78619000 |
Деталь: | DEV-UNIT-2505 |
Парткод: | 6LJ76560000 |
Деталь: | CLN-DRUM-2505 |
Парткод: | 6LJ75530000 |
Деталь: | FUSER-2306-120 |
Парткод: | 6LJ78051100 |
Деталь: | FUSER-2306-230 |
Парткод: | 6LJ78051200 |
Деталь: | GUIDE-FUS-H241 |
Парткод: | 6LJ78036000 |
Деталь: | LG2A14BL1 |
Парткод: | C0-17839000 |
Деталь: | ACTR-EXIT-H24H |
Парткод: | 6LJ78000000 |
Деталь: | SPG-T-ACT-EXIT-282 |
Парткод: | 6LE58862000 |
Деталь: | LBL-W-HOT-280 |
Парткод: | 6LE58890000 |
Деталь: | LBL-FUS-OPE-H24X |
Парткод: | 6LJ78031000 |
Деталь: | HRNS-EXIT-240 |
Парткод: | 6LJ81809000 |
Деталь: | COVER-FUS-PR-H24X |
Парткод: | 6LJ78002000 |
Деталь: | GUIDE-ENT-FUS-H24X |
Парткод: | 6LJ78004000 |
Деталь: | SCREW-SPEAKER-16X |
Парткод: | 6LJ14028000 |
Деталь: | PLT-BIAS-H24X |
Парткод: | 6LJ78003000 |
Деталь: | USUITA-SEMS-3X5-6 |
Парткод: | 6LH55301000 |
Деталь: | LBL/W-FUSER |
Парткод: | 41307995000 |
Деталь: | COVER-FUS-SEN-H24X |
Парткод: | 6LJ78043000 |
Деталь: | S/TPP/BID-3X8-NI |
Парткод: | 6LA80090000 |
Деталь: | COV-FRT-TNR-H241-TN |
Парткод: | 6LJ76014000 |
Деталь: | LBL_O-TNR-CARTG |
Парткод: | 6LJ80009000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | COV-STOP-PAPER-H241D |
Парткод: | 6LE21719400 |
Деталь: | COV-FRT-L-H241-TN |
Парткод: | 6LJ76020000 |
Деталь: | COV-PILLAR-H241-TN |
Парткод: | 6LJ76016000 |
Деталь: | COVER-TRAY-H241-TN |
Парткод: | 6LJ76019000 |
Деталь: | COV-TRAY-BACK-H241-TN |
Парткод: | 6LJ76018000 |
Деталь: | COV-LEFT-U-H241-TN |
Парткод: | 6LJ76017000 |
Деталь: | COV-RIGHT-PH25-TN |
Парткод: | 6LJ76003000 |
Деталь: | COVER-REAR-SUB-H24X |
Парткод: | 6LJ76022000 |
Деталь: | COV-REAR-H241 |
Парткод: | 6LJ76012000 |
Деталь: | S/TPS/FHEXM/R-3X8-ZU3 |
Парткод: | X0-02420000 |
Деталь: | SHEET-SHADE-COV-LFT-PH25S |
Парткод: | 6LJ76031000 |
Деталь: | ASYS-COV-FRT-R-2306 |
Парткод: | 6LJ76024000 |
Деталь: | S/TPD3/FHEXM-4X8-ZU3 |
Парткод: | X0-02589000 |
Деталь: | ASYS-COV-FRT-R-2506 |
Парткод: | 6LJ76024100 |
Деталь: | ASYS-COV-FRT-R-2006 |
Парткод: | 6LJ76024500 |
Деталь: | LBL-CAU-LASER |
Парткод: | 6LJ83461000 |
Деталь: | LBL-CAU-LASER-CND |
Парткод: | 6LJ83375000 |
Деталь: | LBL-CAU-LASER-TWD |
Парткод: | 6LJ83460000 |
Деталь: | LBL-SERVICE-45 |
Парткод: | 44204604000 |
Деталь: | LBL-SERVICE-45C |
Парткод: | 6LA56227000 |
Деталь: | LBL-SERVICE-45-TWD |
Парткод: | 6LA48504000 |
Деталь: | LBL-LASER |
Парткод: | 6LA47529000 |
Деталь: | LBL-LASER-C LBL |
Парткод: | 6LA56226000 |
Деталь: | LBL-LASER-TWD |
Парткод: | 6LA48505000 |
Деталь: | ASYS-COV-SIDE-ADU-H241-TN |
Парткод: | 6LJ74667000 |
Деталь: | LEV-OPEN-COV-SID-H24X |
Парткод: | 6LJ74601000 |
Деталь: | ASYS-SFT-ROL-SFB-H241 |
Парткод: | 6LJ74942000 |
Деталь: | BUSH-8X12X5R5F-BCF-050 |
Парткод: | 6LJ55544000 |
Деталь: | STOP-RING-8 |
Парткод: | 41306265000 |
Деталь: | ASYS-GUIDE-SFB-H241 |
Парткод: | 6LJ74944000 |
Деталь: | SPC-HOL-PAD-SFB |
Парткод: | 6LH51422000 |
Деталь: | ASYS-PAD-BYP-H241 |
Парткод: | 6LJ74945000 |
Деталь: | PUSHER-FUSER-H241 |
Парткод: | 6LJ74638000 |
Деталь: | ASYS-PRS-TY241 |
Парткод: | 6LH51440100 |
Деталь: | ASYS-GID-FED-RU-H241 |
Парткод: | 6LJ74946000 |
Деталь: | LG2A14BL1 |
Парткод: | C0-17839000 |
Деталь: | ACTR-P-EMP-SFB |
Парткод: | 6LH51413000 |
Деталь: | HRNS-SIDE-COV-241 |
Парткод: | 6LJ81900000 |
Деталь: | HLD-DRV-SFB-H241 |
Парткод: | 6LJ74938000 |
Деталь: | CLUTCH-50C-G28-8 |
Парткод: | 6LH51414000 |
Деталь: | ASYS-ROL-BYP |
Парткод: | 6LH51412000 |
Деталь: | SPC-TRAY-SFB |
Парткод: | 6LH51425000 |
Деталь: | BRKT-COV-SIDE-H24X |
Парткод: | 6LJ74618000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | STOPER-GUIDE-FUS-H24X |
Парткод: | 6LJ74620000 |
Деталь: | HRNS-SFB-GND-240 |
Парткод: | 6LJ81890000 |
Деталь: | PLATE-GND-SFB-H241 |
Парткод: | 6LJ74663000 |
Деталь: | S/PAN/SWWP-M3X8-NI |
Парткод: | X0-00077000 |
Деталь: | SCREW-HLDR-MG |
Парткод: | 6LA65683000 |
Деталь: | SPG-LVR-COV-SID-H24X |
Парткод: | 6LJ74655000 |
Деталь: | ASYS-BRKT-PT |
Парткод: | 6LH51438000 |
Деталь: | SPR-STOP-SFB |
Парткод: | 6LJ74948000 |
Деталь: | COV-SW-OPEN-RIGHT-H24X |
Парткод: | 6LJ77709000 |
Деталь: | PLATE-KEY-MODEL-ID-DR |
Парткод: | 6LJ80008100 |
Деталь: | SPG-BIAS-RGST |
Парткод: | 6LJ77408000 |
Деталь: | SPG-BIAS-SEP-H24X |
Парткод: | 6LJ80210000 |
Деталь: | SPG-LOCK-DRUM-F |
Парткод: | 6LJ75518000 |
Деталь: | SPG-BIAS-TR-H24X |
Парткод: | 6LJ80209000 |
Деталь: | SPG-BIAS-FUS-H24X |
Парткод: | 6LJ78020000 |
Деталь: | SPG-BIAS-CH-H24X |
Парткод: | 6LJ78611000 |
Деталь: | SPG-BIAS-DEV |
Парткод: | 6LJ76524000 |
Деталь: | SPG-BIAS-GRID-H24X |
Парткод: | 6LJ78612000 |
Деталь: | PS-12C02-NFS |
Парткод: | E0-14613000 |
Деталь: | ASYS-HLDR-TNR-CARTG |
Парткод: | 6LJ76549000 |
Деталь: | SW-INTERLOCK-H240 |
Парткод: | 6LJ83112000 |
Деталь: | HRNS-MAIN-PU-244 |
Парткод: | 6LJ81879000 |
Деталь: | HRNS-INTERLOCK-241 |
Парткод: | 6LJ81839000 |
Деталь: | S/TPS/FHEXM/R-3X8-ZU3 |
Парткод: | X0-02420000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | PLT-EARTH-F-H24X |
Парткод: | 6LJ77712000 |
Деталь: | S/PAN/SWWP-M3X8-NI |
Парткод: | X0-00077000 |
Деталь: | PS-HVT-H240 |
Парткод: | 6LJ81600000 |
Деталь: | BRKT-FUS-F-H24X |
Парткод: | 6LJ77708000 |
Деталь: | HLDR-CH-M-H24X |
Парткод: | 6LJ78614000 |
Деталь: | PWA-F-DLE-280V-REF |
Парткод: | 6LH27027000 |
Деталь: | SPG-PUSH-CH-H24X |
Парткод: | 6LJ78609000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | SPG-FRAME-DRUM |
Парткод: | 6LJ75520000 |
Деталь: | ASYS-CASE-CH-M |
Парткод: | 6LJ78618000 |
Деталь: | TERM-CH-M-R-H24X |
Парткод: | 6LJ78603000 |
Деталь: | TERM-CH-M-F-H24X |
Парткод: | 6LJ78602000 |
Деталь: | S/TPP/BID-3X8-NI |
Парткод: | 6LA80090000 |
Деталь: | CH-M-H24X |
Парткод: | 6LJ78616000 |
Деталь: | LEVER-GRID-CH-H24X |
Парткод: | 6LJ78605000 |
Деталь: | SPG-CH-M-H24X |
Парткод: | 6LJ78613000 |
Деталь: | SPG-LEVER-CH-H24X |
Парткод: | 6LJ78610000 |
Деталь: | GRID-CH-M-H24X |
Парткод: | 6LJ78604000 |
Деталь: | ROD-CLN-CH-H24X |
Парткод: | 6LJ78606000 |
Деталь: | MYLAR-CLN-CH-H24X |
Парткод: | 6LJ78607000 |
Деталь: | MYLAR-HLDR-CH-M-H24X |
Парткод: | 6LJ78620000 |
Деталь: | GUIDE-RGST-L-H24X |
Парткод: | 6LJ77415000 |
Деталь: | ACTR-RGST-H24X |
Парткод: | 6LJ77416000 |
Деталь: | SPG-ACT-RGST-U |
Парткод: | 6LH56106000 |
Деталь: | SHEET-RGST-H24X |
Парткод: | 6LJ77404000 |
Деталь: | LG2A14BL1 |
Парткод: | C0-17839000 |
Деталь: | S/TPS/FHEXM/R-3X8-ZU3 |
Парткод: | X0-02420000 |
Деталь: | STOP-RING-8 |
Парткод: | 41306265000 |
Деталь: | BUSH-8 |
Парткод: | 4400802080 |
Деталь: | CLUTCH-50C-G28-8 |
Парткод: | 6LH51414000 |
Деталь: | STOP-RING-6-5 |
Парткод: | 4407972860 |
Деталь: | ROLLER-RGST-L-H24X |
Парткод: | 6LJ79509000 |
Деталь: | P/PRL/AH7-2X10-SS |
Парткод: | X0-00980000 |
Деталь: | GEAR-10S015-08 |
Парткод: | 6LE57208000 |
Деталь: | RR/E-7-SS |
Парткод: | X0-00968000 |
Деталь: | MOTR_S-SCN-241 |
Парткод: | 6LJ79734000 |
Деталь: | ASYS-BKT-MOT-SCN-DR |
Парткод: | 6LJ79748000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | PLY-DRV-SCAN-PH25 |
Парткод: | 6LJ79706000 |
Деталь: | ARM-TENS-BELT-PH25 |
Парткод: | 6LJ79705000 |
Деталь: | PLY-TENSION-12 |
Парткод: | 6LE60654000 |
Деталь: | BELT-DRV-CIS-DR |
Парткод: | 6LJ79744000 |
Деталь: | CASE-CIS-PH25 |
Парткод: | 6LJ79700000 |
Деталь: | SNSR-CISM-H240 |
Парткод: | 6LJ79733000 |
Деталь: | SPRING-TENS-PH25 |
Парткод: | 6LJ79709000 |
Деталь: | ASYS-SCAN-U-DR |
Парткод: | 6LJ79763000 |
Деталь: | ASYS-BASE-SCAN-DR |
Парткод: | 6LJ79754000 |
Деталь: | S/TPP/FHEXM-3X10-NI |
Парткод: | X0-02248000 |
Деталь: | S/TPS/FHEXM/R-3X8-ZU3 |
Парткод: | X0-02420000 |
Деталь: | FOOT-CRG-DR |
Парткод: | 6LJ79774000 |
Деталь: | GUIDE-SLIDE-CIS-DR |
Парткод: | 6LJ79773000 |
Деталь: | SLIDER-CIS-PH25 |
Парткод: | 6LJ79703000 |
Деталь: | SPG-C-5XR65X10R1 |
Парткод: | 6LJ79764000 |
Деталь: | GUIDE-RAIL-SCAN-DR |
Парткод: | 6LJ79772000 |
Деталь: | S/PAN/SWWP-M3X6-ZU3-B |
Парткод: | 6LE43405000 |
Деталь: | LBL-PROHIBIT-C-H24X |
Парткод: | 6LJ82613000 |
Деталь: | LBL-PROHIBIT-E-H24X |
Парткод: | 6LJ82612000 |
Деталь: | LBL-PROHIBIT-U-H24X |
Парткод: | 6LJ82610000 |
Деталь: | ASYS-BRKT-ACTR-EMPTY-H241 |
Парткод: | 6LJ77752000 |
Деталь: | BRKT-SNSR-280 |
Парткод: | 6LE53708000 |
Деталь: | ACTR-SNSR-280 |
Парткод: | 6LE53709000 |
Деталь: | MYLAR-SUPPORT-SNS |
Парткод: | 6LA85910000 |
Деталь: | SCRAPER-RGST-H24X |
Парткод: | 6LJ77739000 |
Деталь: | LG2A14BL1 |
Парткод: | C0-17839000 |
Деталь: | ES-0505 |
Парткод: | F0-00120000 |
Деталь: | UAMS-02WL-0 |
Парткод: | F0-01046000 |
Деталь: | HRNS-CST-EMP-240 |
Парткод: | 6LJ81853000 |
Деталь: | S/TPS/FHEXM/R-3X8-ZU3 |
Парткод: | X0-02420000 |
Деталь: | HEATER-D-DRM-280U |
Парткод: | 6LE64029000 |
Деталь: | HEATER-D-DRM-280E |
Парткод: | 6LE64030000 |
Деталь: | COV-DHTR-H24X |
Парткод: | 6LJ77743000 |
Деталь: | HRNS-DHT-241 |
Парткод: | 6LJ81871000 |
Деталь: | LWS-1U |
Парткод: | F0-00024000 |
Деталь: | SCR-M3X6BISR-NI |
Парткод: | 6LA08935000 |
Деталь: | T18R |
Парткод: | F0-01012000 |
Деталь: | THRMST-CS-7L |
Парткод: | 6LE09486000 |
Деталь: | DEV-KIT-2505 |
Парткод: | 6LJ83350000 |
Деталь: | S/TPS/FHEXM/R-3X8-ZU3 |
Парткод: | X0-02420000 |
Деталь: | ASYS-BRKT-STY-H241 |
Парткод: | 6LJ77790000 |
Деталь: | BKT-STY-LSU-H241 |
Парткод: | 6LJ77748000 |
Деталь: | CF-LA-2KZ2-1C |
Парткод: | E0-14534000 |
Деталь: | COV-LFT-241-TN |
Парткод: | 6LJ77747000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | STAY-F-LOW-H241 |
Парткод: | 6LJ77753000 |
Деталь: | S/TPP/BID-3X8-NI |
Парткод: | X0-01989000 |
Деталь: | LSU-2505 |
Парткод: | 6LJ78326000 |
Деталь: | SHEET-BARR-TONER |
Парткод: | 6LJ76557000 |
Деталь: | USUITA-SPSEMS-4X8-6 |
Парткод: | 6LH55300000 |
Деталь: | BKT-STY-L-H241 |
Парткод: | 6LJ77757000 |
Деталь: | HRNS-LDR-241 |
Парткод: | 6LJ81823000 |
Деталь: | HRNS-POL-241 |
Парткод: | 6LJ81824000 |
Деталь: | HRNS-ACIN1-241E |
Парткод: | 6LJ81909000 |
Деталь: | HRNS-ACIN1-241J |
Парткод: | 6LJ81908000 |
Деталь: | PWA-PSU-H240-EU |
Парткод: | 6LG06587300 |
Деталь: | PS-ACC-240JU |
Парткод: | 6LJ81603000 |
Деталь: | HRNS-INLET-240 |
Парткод: | 6LJ81805000 |
Деталь: | HRNS-INLET-DH-240 |
Парткод: | 6LJ81878000 |
Деталь: | CABLE-P-INLET-UK |
Парткод: | 6LJ83117000 |
Деталь: | CABLE-P-INLET-AR |
Парткод: | 6LE95824000 |
Деталь: | CABLE-P-INLET-CCC |
Парткод: | 6LJ83118000 |
Деталь: | CABLE-P-INLET-EUR |
Парткод: | 6LE95822000 |
Деталь: | CABLE-P-INLET-TWD |
Парткод: | 6LE95826000 |
Деталь: | CABLE-P-INLET-NAD-15A |
Парткод: | 6LJ60950000 |
Деталь: | LBL-CAU-LASER |
Парткод: | 6LJ83461000 |
Деталь: | LBL-CAU-LASER-CND |
Парткод: | 6LJ83375000 |
Деталь: | LBL-CAU-LASER-TWD |
Парткод: | 6LJ83460000 |
Деталь: | TRAY-CST-LE_4 |
Парткод: | 6LJ46900000 |
Деталь: | STOP-PLATE-CST-4 |
Парткод: | 6LJ46939000 |
Деталь: | SPG-LATCH-TRAY |
Парткод: | 6LE53730000 |
Деталь: | SPG-CSSTT-280 |
Парткод: | 6LE53732000 |
Деталь: | SLIDE-WALL-R-G |
Парткод: | 6LJ46901000 |
Деталь: | WALL-CST-END-LE_4-G |
Парткод: | 6LJ46915100 |
Деталь: | ASYS-PLATE-CSSTT-G |
Парткод: | 6LJ46913000 |
Деталь: | SPG-PAD-CHA-G |
Парткод: | 6LJ46907000 |
Деталь: | ASYS-HOLD-PAD-G |
Парткод: | 6LJ46914000 |
Деталь: | ASYS-ROL-CST-G |
Парткод: | 6LJ46904000 |
Деталь: | ASYS-ROL-CST-36-L35 |
Парткод: | 6LJ46929000 |
Деталь: | BUSH-8X12X8F-NU4 |
Парткод: | 6LH23442000 |
Деталь: | CATCH-CST-H241 |
Парткод: | 6LJ75227000 |
Деталь: | COVER-CST-H241 |
Парткод: | 6LJ75226000 |
Деталь: | SPG-T-END-WALL |
Парткод: | 6LJ46922000 |
Деталь: | LBL-CST-MAX-LE_4 |
Парткод: | 6LJ46927000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | LBL-OPE-CST |
Парткод: | 6LJ46928000 |
Деталь: | BRKT-TRAY-280 |
Парткод: | 6LE53746000 |
Деталь: | S/TPP/BID-3X8-NI |
Парткод: | X0-01989000 |
Деталь: | GEAR-10S18-8-TRAY |
Парткод: | 6LE53717000 |
Деталь: | STOP-RING-8 |
Парткод: | 41306265000 |
Деталь: | LEVER-LOCK-WALL-GG |
Парткод: | 6LJ46916100 |
Деталь: | P/PRL/AH7-2X16-SS |
Парткод: | X0-01533000 |
Деталь: | PLT-WALL-GEAR-G |
Парткод: | 6LJ46917000 |
Деталь: | SHAFT_STOPER_WALL |
Парткод: | 6LJ46919000 |
Деталь: | SLIDE-WALL-F-G |
Парткод: | 6LJ46902000 |
Деталь: | SPC-LVR-WALL-F |
Парткод: | 6LA56695000 |
Деталь: | LBL-CST-PUSH-280E |
Парткод: | 6LJ46937000 |
Деталь: | LBL-CST-PUSH-280A |
Парткод: | 6LJ46936000 |
Деталь: | SIZE-CST-450-A4 |
Парткод: | 6LH31900000 |
Деталь: | SIZE-CST-450-K |
Парткод: | 6LH31900200 |
Деталь: | SIZE-CST-450-LT |
Парткод: | 6LH31900100 |
Деталь: | COUPL-CST-H21X_L |
Парткод: | 6LJ56336000 |
Деталь: | S/TPS/FHEXM/R-3X8-ZU3 |
Парткод: | X0-02420000 |
Деталь: | SPG-F-TNRIC-H21X-G |
Парткод: | 6LJ54890000 |
Деталь: | SPG-LOCK-DRUM-R |
Парткод: | 6LJ75519000 |
Деталь: | SPG-F-TNRIC-H21X |
Парткод: | 6LJ54889000 |
Деталь: | SPG-T-LOCK-DEV |
Парткод: | 6LJ76525000 |
Деталь: | SPG-EARTH-FUS-H24X |
Парткод: | 6LJ78021000 |
Деталь: | SPG-C-DRV-TNR-H24X |
Парткод: | 6LJ76826000 |
Деталь: | STUD-TNRDRV-H24X |
Парткод: | 6LJ76822000 |
Деталь: | BUSH-6-POM |
Парткод: | 44201492000 |
Деталь: | PWA-H-CTIF-240 |
Парткод: | 6LJ81223000 |
Деталь: | CHS-CGC5-28 |
Парткод: | D0-32012000 |
Деталь: | STOP-RING-6-1.5 |
Парткод: | 44201801000 |
Деталь: | RR/E-3-SS |
Парткод: | X0-00964000 |
Деталь: | RR/E-5-SS |
Парткод: | X0-00966000 |
Деталь: | S/TPP/FHEXM-3X8-NI |
Парткод: | X0-02247000 |
Деталь: | BOS-CENTER-COV-ADU-H241 |
Парткод: | 6LJ77756000 |
Деталь: | GEAR-05H60-DRV-TNR-H24X |
Парткод: | 6LJ76817000 |
Деталь: | BRKT-DRVTNR-H24X |
Парткод: | 6LJ76821000 |
Деталь: | ASYS-MOTRD-TNR-470 |
Парткод: | 6LH53764000 |
Деталь: | S/BID-M2.6X3-NI |
Парткод: | X0-02557000 |
Деталь: | AJ76101BF |
Парткод: | E0-11767000 |
Деталь: | EN25F40-100QCP |
Парткод: | C0-18733000 |
Деталь: | THMS-DRM-240 |
Парткод: | 6LJ83115000 |
Деталь: | S/PAN/SWWP-M3X8-NI |
Парткод: | X0-00077000 |
Деталь: | PS-12C02-NFS |
Парткод: | E0-14613000 |
Деталь: | LWS-1316Z |
Парткод: | F0-01245000 |
Деталь: | CPG-TC-470-D |
Парткод: | 6LH57004100 |
Деталь: | CPG-TC-470-C |
Парткод: | 6LH57004400 |
Деталь: | CPG-TC-470-E |
Парткод: | 6LH57004300 |
Деталь: | CPG-TC-470-J |
Парткод: | 6LH57004000 |
Деталь: | CPG-TC-470-U |
Парткод: | 6LH57004200 |
Деталь: | BRKT-BOARD-DHTR-H24X |
Парткод: | 6LJ77769000 |
Деталь: | PWA-H-FUS-240 |
Парткод: | 6LJ81220000 |
Деталь: | PWA-H-MAIN-241 |
Парткод: | 6LJ81236000 |
Деталь: | PWA-H-MAIN-242 |
Парткод: | 6LJ81236100 |
Деталь: | PWA-H-MAIN-247 |
Парткод: | 6LJ81236200 |
Деталь: | ASYS-FRM-FUS-H241 |
Парткод: | 6LJ78049000 |
Деталь: | ASYS-THMTD-H24X |
Парткод: | 6LJ78015000 |
Деталь: | ROLL-FUS-GUIDE |
Парткод: | 6LE25931000 |
Деталь: | PLT-NUT-LMP-H241 |
Парткод: | 6LJ78039000 |
Деталь: | THRMST-HTR-284 |
Парткод: | 6LH27402000 |
Деталь: | HRNS-ACIN2-241 |
Парткод: | 6LJ81836000 |
Деталь: | HRNS-THRMST-CS-241 |
Парткод: | 6LJ81837000 |
Деталь: | ASYS-HLD-ROLL-H24X |
Парткод: | 6LJ78011000 |
Деталь: | BUSH-FUS-HR-H24X |
Парткод: | 6LJ78009000 |
Деталь: | HR-2505-U |
Парткод: | 6LJ83405000 |
Деталь: | GEAR-FUS-HR |
Парткод: | 6LJ78008000 |
Деталь: | RING-C-H24X |
Парткод: | 6LJ78010000 |
Деталь: | GEAR-10S20-6 |
Парткод: | 6LJ78007000 |
Деталь: | SCRAPER-282 |
Парткод: | 6LE58405000 |
Деталь: | SPE-SCR-HR-371 |
Парткод: | 6LA84096000 |
Деталь: | HR-2505-L |
Парткод: | 6LJ83406000 |
Деталь: | BUSH-PRS-0-H24X |
Парткод: | 6LJ78040000 |
Деталь: | ARM-PRS-H24X-F |
Парткод: | 6LJ78005000 |
Деталь: | LVR-P-REL-24X |
Парткод: | 6LE58710100 |
Деталь: | SPE-PR-H24X |
Парткод: | 6LJ78030000 |
Деталь: | THMS-HTR-241 |
Парткод: | 6LJ83114000 |
Деталь: | S/PAN/SWWP-M3X8-NI |
Парткод: | X0-00077000 |
Деталь: | S/BID-M3X8-NI |
Парткод: | X0-00434000 |
Деталь: | SCREW-SPEAKER-16X |
Парткод: | 6LJ14028000 |
Деталь: | USUITA-SEMS-3X5-6 |
Парткод: | 6LH55301000 |
Деталь: | S/PAN/SWWP-M3X10-NI |
Парткод: | X0-00094000 |
Деталь: | SCREW-M3-FUS-C |
Парткод: | 6LA36276000 |
Деталь: | S/TPP/BID-3X8-NI |
Парткод: | 6LA80090000 |
Деталь: | WASHER-HR-H24X |
Парткод: | 6LJ78048000 |
Деталь: | HRNS-THRMST-SL-241 |
Парткод: | 6LJ81838000 |
Деталь: | THRMST-HTR-S-470 |
Парткод: | 6LH64642000 |
Деталь: | LAMP-HTR-C-H24X-120 |
Парткод: | 6LJ78024100 |
Деталь: | LAMP-HTR-C-H24X-230 |
Парткод: | 6LJ78024200 |
Деталь: | LAMP-HTR-S-H24X-120 |
Парткод: | 6LJ78023100 |
Деталь: | LAMP-HTR-S-H24X-230 |
Парткод: | 6LJ78023200 |
Деталь: | COVER-DUMMY-DR |
Парткод: | 6LJ75804000 |
Деталь: | SITPPIFHEXM-3XB-NI |
Парткод: | X0-02247000 |
Деталь: | ASYB-CONPANE-DR-NAD |
Парткод: | 6LJ75801000 |
Деталь: | ASYB-CONPANE-DR-CND |
Парткод: | 6LJ75801100 |
Деталь: | ASYB-CONPANE-DR-ASD |
Парткод: | 6LJ75801200 |
Коды ошибок
C010
C260
C270
C411
C412
C413
C414
C415
C447
C449
C452
C4B0
C911
C940
C950
C970
CA10
CA20
CE50
CE90
E010
E020
E030
E061
E062
E065
E090
E110
E120
E130
E140
E210
E400
E410
E430
E440
E510
E550
E552
E714
E721
E725
E726
EAD0
EB50
EB60
F070
F090
F901
Описание
Error code: | C010 |
Description: | Main motor abnormality: The main motor is not rotating normally. |
Causes: | Main motor LGC board |
Remedy: | 1 Is the main motor working? (Perform the output check in the test mode: 03-101/151) Yes 2 No 1. Check if the connector CN1 of the main motor is disconnected. 2. Check if the connector CN308 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the main motor board and LGC board are short circuited or open circuited. 5. Replace the main motor. 6. Replace the LGC board. 2 Are there any damage or scratches on the main motor board? Yes 3 No 1. Check if the connector pins are disconnected and the harnesses are open circuited. 2. Check if the conductor patterns on the main motor board and LGC board are short circuited or open circuited. 3. Replace the main motor. 4. Replace the LGC board. 3 LGC board 1. Check if the PLL lock signal CN308-8 output from the LGC board is always level "L"? 2. Check if the voltage supplied to the CPU input terminal IC22-98 is always "L"? 3. Replace the LGC board. |
Error code: | C260 |
Description: | Peak detection error: Lighting of the exposure lamp (white reference) is not detected when the power is turned ON. |
Causes: | Lens unit SLG board Exposure lamp Supply harness |
Remedy: | Does the exposure lamp light? (Perform the output check in the test mode: 03-267) ↓ → YES → 1. Check if the connectors on the CCD and SLG boards are disconnected. 2. Check if the shading correction plate is detached or dirty. 3. Check if the conductor pattern on the CCD board is short circuited or open circuited. 4. Check if the conductor pattern on the SLG board is short circuited or open circuited. 5. Replace the lens unit. 6. Replace the SLG board. NO 1. Check if the connectors of the exposure lamp and inverter are disconnected. 2. Check the SLG board if the connector pin CN1 is disconnected and the harness is short circuited or open circuited. 3. Check if the conductor pattern on the SLG board is short circuited or open circuited. 4. Replace the SLG board. 5. Replace the inverter. 6. Replace the exposure lamp. |
Error code: | C270 |
Description: | Carriage home position sensor not turning OFF within a specified period of time: The carriages do not shift from their home position within a specified period of time. |
Causes: | Carriage home position sensor Carriage home position sensor harness SLG board Scan motor Scan motor harness |
Remedy: | Remove the original glass and move the carriages to the paper feeding side. Turn ON the power and check the following items. Are the carriages slightly moved to the feeding direction? Are the carriages staying at a position other than home position? ll → YES → 1. Check if the conductor pattern on the SLG board is short circuited or open circuited. 2. Replace the SLG board. NO 1. Check if the connector pin is disconnected and the harness is short circuited or open circuited. 2. Check if the conductor pattern on the SLG board is short circuited or open circuited. 3. Replace the SLG board. |
Error code: | C411 |
Description: | Thermistor/heater abnormality at power-ON: Thermistor abnormality is detected at power-ON or the fuser roller temperature does not rise within a specified period of time after power-ON. |
Causes: | Thermopiles Fuser unit IH coil IH board LGC board |
Remedy: | 1.Check the power voltage (1) Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2.Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the center and side thermistors (front, rear) are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center and side thermistors (front, rear) are open circuited. 3. Check the heater (1) Check if the IH coil is broken. (2) Check if the connector of the IH coil is disconnected. (3) Check if the thermostat is blown. (4) Check if the connectors on the IH control board are disconnected (AC input connector and LGC I/F connectors CN455). (5) Check if the IH control board is abnormal. • Replace the IH control board. 4. Check the LGC board (1) Check if the connectors CN332,CN334 are disconnected. (2) Check if the conductor pattern on the LGC board is short circuited or open circuited. (3) Replace the LGC board. 5. Clear the status counter After repairing the matter which caused the error [C411/C412], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in "400", then press [START]. (3) Change the current status counter value "1" or "2" to "0", then press [ENTER] or [INTERRUPT] (to cancel [C411/C412]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. |
Error code: | C412 |
Description: | Thermistor/heater abnormality at power-ON: Thermistor abnormality is detected at power-ON or the fuser roller temperature does not rise within a specified period of time after power-ON. |
Causes: | Thermopiles Fuser unit IH coil IH board LGC board |
Remedy: | 1.Check the power voltage (1) Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2.Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the center and side thermistors (front, rear) are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center and side thermistors (front, rear) are open circuited. 3. Check the heater (1) Check if the IH coil is broken. (2) Check if the connector of the IH coil is disconnected. (3) Check if the thermostat is blown. (4) Check if the connectors on the IH control board are disconnected (AC input connector and LGC I/F connectors CN455). (5) Check if the IH control board is abnormal. • Replace the IH control board. 4. Check the LGC board (1) Check if the connectors CN332,CN334 are disconnected. (2) Check if the conductor pattern on the LGC board is short circuited or open circuited. (3) Replace the LGC board. 5. Clear the status counter After repairing the matter which caused the error [C411/C412], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in "400", then press [START]. (3) Change the current status counter value "1" or "2" to "0", then press [ENTER] or [INTERRUPT] (to cancel [C411/C412]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. |
Error code: | C413 |
Description: | Fuser unit related service call. Thermistor abnormality during warming up or in ready status after abnormality judgment. |
Causes: | MAIN board Thermistors Heater lamp |
Remedy: | 1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?) 2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter 3 Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 4 Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 5 Check the MAIN board 1. Check if the connectors are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board. 6 Clear the status counter After repairing the matter which caused the error [C413 / C414], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press [START]. 3. Change the current status counter value “1” or “2” to “0”, then press [OK] (to cancel [C413 / C414]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. |
Error code: | C414 |
Description: | Fuser unit related service call. Temperature of the fuser roller did not reach to "temperature for ready condition" at specified period of time during warming-up. |
Causes: | MAIN board Thermistors Heater lamp |
Remedy: | 1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?) 2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter 3 Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 4 Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 5 Check the MAIN board 1. Check if the connectors are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board. 6 Clear the status counter After repairing the matter which caused the error [C413 / C414], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in "2002", then press [START]. 3. Change the current status counter value "1" or "2" to "0", then press [OK] (to cancel [C413 / C414]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. |
Error code: | C415 |
Description: | Fuser unit related service call. No recovery even after one minute elapses after low temperature WAIT state is entered during a printing operation. |
Causes: | MAIN board |
Remedy: | 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 3. Check the MAIN board 1. Check if the connectors CN10 are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board 4. Check the power supply 1. Check if the connectors are disconnected. 2. Replace the switching regulator. 5. Clear the status counter After repairing the matter which caused the error [C415], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press [START]. 3. Change the current status counter value “5” to “0”, then press [OK] (to cancel [C415]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. |
Error code: | C447 |
Description: | Heater abnormality after abnormality judgment (temperature abnormality at ready status) |
Causes: | Thermopiles Fuser unit IH coil IH board LGC board |
Remedy: | 1,2.3. Check the thermistors, Heater and LGC board Check the above components following the procedures 1, 2 and 3 for [C411/C412]. 4. Clear the status counter Change the current status counter value (08-400) "3", "5" , "6" , "9" , "19" , "21" , "22" , "23" , "24" , "25" , "27" or "29" to "0" for [C44X], taking the same procedure as that for [C41X]. • The status counter value is as follows in the following cases. - The error occurred during warming-up: "3", "5" or "6" - The error occurred after the equipment has become ready: "7" - The temperature detected by the center thermistor is 240°C or higher, the temperature detected by the side thermistor is 250°C or higher or the temperature detected by the edge thermistor is 270°C or higher: "9", "19", "21", "22", "23", "25", "27" or "29". - The error occurred during printing: "24" or "25" - The error occurred during energy saving: "26" or "27" - A paper jam occurred: "28" or "29" |
Error code: | C449 |
Description: | Heater abnormality after abnormality judgment (overheating) |
Causes: | Thermopiles Fuser unit IH coil IH board LGC board |
Remedy: | 1,2.3. Check the thermistors, Heater and LGC board Check the above components following the procedures 1, 2 and 3 for [C411/C412]. 4. Clear the status counter Change the current status counter value (08-400) "3", "5" , "6" , "9" , "19" , "21" , "22" , "23" , "24" , "25" , "27" or "29" to "0" for [C44X], taking the same procedure as that for [C41X]. • The status counter value is as follows in the following cases. - The error occurred during warming-up: "3", "5" or "6" - The error occurred after the equipment has become ready: "7" - The temperature detected by the center thermistor is 240°C or higher, the temperature detected by the side thermistor is 250°C or higher or the temperature detected by the edge thermistor is 270°C or higher: "9", "19", "21", "22", "23", "25", "27" or "29". - The error occurred during printing: "24" or "25" - The error occurred during energy saving: "26" or "27" - A paper jam occurred: "28" or "29" |
Error code: | C452 |
Description: | Thermopile temperature difference |
Causes: | Power supply unit Thermopile LGC board |
Remedy: | 1.Check the power voltage (1) Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2.Check the error detection history (1) Check the error detection history of each temperature detecting element when the error occurred. If any of the elements detects an abnormal temperature, check step 3. 08-1902: Fuser belt center thermopile temperature 08-1903: Fuser belt side thermopile temperature 08-1904: Fuser belt edge thermistor temperature 08-1905: Pressure roller center thermistor temperature 08-4545: Pressure roller rear thermistor temperature 3.Check the thermopiles (1) Check if the fuser belt center and side thermopiles (front, rear) are installed properly. (2) Check if the harnesses of the fuser belt center and side thermopiles (front, rear) are open circuited. 4. Check the IH board, IH coil and the fuser unit (1) Is the fuser unit installed correctly? (2) heck if foreign matter or paper in the fuser unit is plugging up the monitoring opening of the fuser belt thermopile. (3) Check if the opening of the fuser belt thermopile of the equipment is plugged up. (4) Is the IH coil open circuited? (Check if power is supplied to the IH coil.) (5) Check if the connector of the IH coil is disconnected. (6) Check if the thermostat is broken. (7) Check if any of the connectors (AC input connector and LGC I/F connector CN462) on the IH board is disconnected. (8) Is the IH board broken?. • Replace the IH board. 5. Check the LGC board (1) Check if the connectors CN333 and CN345 are disconnected. (2) Check if the conductor pattern on the LGC board is short circuited or open circuited. (3) Replace the LGC board. 6. Clear the status counter After repairing the matter which caused the error [C411/C412], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in “400”, then press [START]. (3) Change the current status counter value “1” or “2” to “0”, then press [ENTER] or [INTERRUPT] (to cancel [C411/C412]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. |
Error code: | C4B0 |
Description: | Fuser unit counter abnormality |
Causes: | LGC board |
Remedy: | 1. Check the LGC board (1) Check if the conductor pattern on the board is short circuited or open circuited. (2) Check if NVRAM is mounted. (3) Replace the LGC board. 2. Clear the status counter Change the current status counter value (08-400) "30 or more" or "4" to "0". |
Error code: | C911 |
Description: | Toner cartridge IC chip access board abnormality |
Causes: | Toner cartridge LGC board HRNS-LGC-TNRIC-212 CTIF board |
Remedy: | 1 Does non-genuine toner cartridge display appear when the front cover is opened and closed? Yes Use the genuine toner cartridge. No 2 2 Toner cartridge • Check the phenomenon by removing the toner cartridges (Y, M, C and K) and reinserting them. • Check that the CTRG board of each cartridge (Y, M, C and K) is installed properly. • Avoid touching the contact point. • Wipe the contact point with a soft cloth if it`s stained. 3 Contact point on the equipment side Check that the spring of the contact point for each color (Y, M, C and K) is not deformed. 4 Is the spring of the contact point returned when it is pushed lightly? Yes No • Check that the CTIF board is installed properly. • Board check 7 Notes: The spring of the contact point may be released if you push the toner cartridge all the way in when an abnormality occurs. 5 LGC board • Connector check (CN375) • Board check 6 HRNS-LGC-TNRIC-212 • Connector check (CN375, CN440) • Harness check 7 CTIF board for each color (Y, M, C and K) • Check that the board is installed properly. • Board check |
Error code: | C940 |
Description: | Engine-CPU abnormality |
Causes: | LGC board |
Remedy: | Is the “Call for Service” displayed even after the power is turned OFF and back ON? → NO → Leave it and see what happens. YES 1. Check if the circuit pattern between the Engine-CPU and FROM is short circuited or open circuited. 2. Replace the LGC board if this error occurs frequently. |
Error code: | C950 |
Description: | LGC board memory abnormality |
Causes: | MAIN board |
Remedy: | (1) Check if the connectors CN331 and CN 343 on the SYS board are completely inserted or not disconnected. (2) Check if the connector CN434 on the DRV board is completely inserted or not disconnected. (3) Check if the conductor pattern on each board is short circuited or open circuited. (4) Replace the NVRAM. (5) Replace the LGC board. (6) Replace the DRV board. (7) Replace the SYS board. (8) Ask a specialist for a repair (Abnormal ID). |
Error code: | C970 |
Description: | High-voltage transformer leakage abnormality: The high-voltage leakage of the main charger is detected. |
Causes: | Main charger |
Remedy: | (1) Is the main charger installed securely? (2) Check if the spring of high-voltage supply contact point is deformed. (3) Check if the main charger wire is broken or the main charger grid is deformed. (4) Check if any foreign matters is on the main charger win or the main charger grid. (5) Replace the High-voltage transformer. (6) Replace the LGC board. |
Error code: | CA10 |
Description: | Polygonal motor abnormality: The polygonal motor does not run normally. |
Causes: | Polygonal motor Laser unit cooling fan (front) Laser unit cooling fan (rear) LGC board Laser optical unit |
Remedy: | Is the polygonal motor rotating? ↓ → NO → (e-STUDIO555/655) 1. Check if the connector CN209 on the PLG board is disconnected. 2. Check if the harness is open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN209 on the PLG board. Pin 1: 27±1V, Pin 2: GND, Pin 5: Less than or equal to 1V (Lo), Pin 4: Less than or equal to 0.7 V (Lo), Pin 3: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Replace the laser optical unit. 6. Replace the PLG board. (e-STUDIO755/855) 1. Check if the connector CN206 on the PLG board is disconnected. 2. Check if the harness is open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN206 on the PLG board. Pin 5: 24±1V, Pin 4: GND, Pin 3: Less than or equal to 1V (Lo), Pin 2: Less than or equal to 0.7 V (Lo), Pin 1: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Replace the laser optical unit. 6. Replace the PLG board. YES Is the deformed image output? ↓ → NO → (e-STUDIO555/655) 1. Check if the connector CN209 on the PLG board is about to be disconnected. 2. Check if the harness is about to be open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN209 on the PLG board. Pin 1: 27±1V, Pin 2: GND, Pin 5: Less than or equal to 1V (Lo), Pin 4: Less than or equal to 0.7 V (Lo), Pin 3: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Check if the laser unit cooling fan is not stopped. 6. Check if the intake area of the laser unit cooling fan is not blocked. 7. Replace the laser optical unit. 8. Replace the PLG board. (e-STUDIO755/855) 1. Check if the connector CN206 on the PLG board is about to be disconnected. 2. Check if the harness is about to be open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN206 on the PLG board. Pin 5: 24±1V, Pin 4: GND, Pin 3: Less than or equal to 1V (Lo), Pin 2: Less than or equal to 0.7 V (Lo), Pin 1: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Check if the laser unit cooling fan is not stopped. 6. Check if the intake area of the laser unit cooling fan is not blocked. 7. Replace the laser optical unit. 8. Replace the PLG board. YES 1. Check if the conductor pattern on the PLG board is short circuited or open circuited. 2. Check if the grounding wire of the high-voltage unit (e.g. developer unit, transfer unit) is grounded securely. 3. Check if the bias contact point of the high-voltage unit is contacted securely. (Check if the point is not stained either.) 4. Check if the metal plates of the transport system are grounded securely. 5. Check if the equipment is grounded securely? 6. Check if the laser unit cooling fan is not stopped. 7. Check if the intake area of the laser unit cooling fan is not blocked. 8. Replace the laser optical unit. |
Error code: | CA20 |
Description: | H-sync detection error: Laser beam cannot be detected at the SNS board. |
Causes: | LGC board Laser optical unit |
Remedy: | (e-STUDIO555/655) Is the harness connecting the connector (J207) on the PLG board and the connector on the LDR1 board open circuited? Are the connectors damaged or disconnected? Is the harness connecting the connector (CN202) on the PLG board and the connector on the SNS board open circuited? Are the connectors damaged or disconnected? (e-STUDIO755/855) Is the harness connecting the connector (J207) on the PLG board and the connector on the LDR1 board open circuited? Are the connectors damaged or disconnected? Is the harness connecting the connector (J208) on the PLG board and the connector on the LDR1 board open circuited? Are the connectors damaged or disconnected? Is the harness connecting the connector (J210) on the PLG board and the connector on the SNS board open circuited? Are the connectors damaged or disconnected? ↓ → NO → (e-STUDIO555/655) 1. Replace the harness. Reconnect the connector. 2. Check if the connector(J207) on PLG board hold the harness securely? 3. Check if the following signals are transmitted on the pin of the connector(CN1) on the PLG board? Pin 1: 5V, Pin 3: 0V 4. Replace the laser optical unit. (e-STUDIO755/855) 1. Replace the harness. Reconnect the connector. 2. Check if the connector(J207,J208) on PLG board hold the harness securely? 3. Replace the laser optical unit. YES 1. Check if the conductor pattern on the PLG board is short circuited or open circuited. 2. Check if the grounding wire of the high-voltage unit (e.g. developer unit, transfer unit) is grounded securely. 3. Check if the bias contact point of the high-voltage unit is contacted securely. (Check if the point is not stained either.) 4. Check if the metal plates of the transport system are grounded securely. 5. Check if the equipment is grounded securely? 6. Replace the laser optical unit. |
Error code: | CE50 |
Description: | Temperature/humidity sensor abnormality: The output value of the temperature/humidity sensor is out of the specified range. |
Causes: | Temperature/humidity sensor LGC board |
Remedy: | Is the connector CN338 on the LGC board or the connector of the temperature/humidity sensor (S7) disconnected? Is the harness between the LGC board and the temperature/humidity sensor disconnected? → YES → Connect the connector securely. Replace the harness. NO 1. Check the connection of the KEY board and DSP board. 2. Check the connection of the DSP board and LGC board. 3. Replace the temperature/humidity sensor. 4. Replace the LGC board. |
Error code: | CE90 |
Description: | Drum thermistor abnormality: The output value of the drum thermistor is out of the specified range. |
Causes: | Drum thermistor-K Drum thermistor-Y EPU board LGC board |
Remedy: | Is the connector CN337 on the LGC board, or the connector of the drum thermistor disconnected? Is the harness between the LGC board and the drum thermistor (THM5) disconnected? → YES → Connect the connector securely. Replace the harness. NO 1. Replace the drum thermistor. 2. Replace the LGC board. |
Error code: | E010 |
Display: | E010 |
Description: | Paper not reaching fuser transport sensor: Paper which has passed the fuser unit does not reach the fuser transport sensor. |
Causes: | Fuser transport sensor LGC board ADU board PFC board Fuser unit |
Remedy: | Open the jam access cover. Is there any paper on the transport path or in the fuser unit? → YES → Remove the paper. NO Is the fuser transport sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[7]/[C]) ↓ → NO → 1. Check if the connector of the fuser transport sensor is disconnected. 2. Check if the connector CN332 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the fuser transport sensor. 6. Replace the LGC board. YES Is the transfer belt working? ↓ → NO → 1. Check if the connector of the transport belt is disconnected. 2. Check if the connector on the transport motor driving PC board is disconnected. 3. Check if the connector CN341 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 6. Replace the transport motor driving PC board. 7. Replace the LGC board. YES Is the drum separation finger solenoid working? (Perform the output check in the test mode: 03-111,161) ↓ → NO → 1. Check if the connector of the drum separation finger solenoid is disconnected. 2. Check if the connector CN339 on the LGC board is disconnected. 3. Check the installation state of cleaner. 4. Is the relay connector connecting the cleaner unit and the equipment disconnected or stained with toner? 5. Replace the drum separation finger solenoid. 6. Replace the LGC board. YES Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[4]/[E]) ↓ → NO → 1. Check if the connector of the registration sensor is disconnected. 2. Check if the registration sensor is installed correctly. 3. Check if the registration actuator is operating properly. 4. Check if the connector CN341 on the LGC board is disconnected. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor pattern on the LGC board is short circuited or open circuited. 7. Replace the registration sensor. 8. Replace the LGC board. YES Is the registration motor working? (Perform the output check in the test mode: 03-108/158) ↓ → NO → 1. Check if the connector of the registration roller clutch is disconnected. 2. Check if the connector CN341 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the registration roller clutch. 6. Replace the LGC board. YES Check if there is any abnormality in the space between the registration motor and the registration roller (metal). Check if the registration roller (rubber) is rotating smoothly. Check the condition of the registration roller at the horizontal transport section and clean or replace it. * If the error [E010] caused by a paper jam underneath the drum cleaner often occurs due to an insufficient paper separation from the photoconductive drum, set a smaller value in the code 08-841, and see what happens. At this time, however, pay attention to the transferability at the leading edge of the paper since this transferability can be slightly narrowed depending on the environments and conditions under which the equipment is placed or the media type of the paper used. (Refer to 3.6.1 in this manual about the details of the code 08-841.) |
Error code: | E020 |
Description: | Paper stopping at fuser transport sensor: The trailing edge of paper does not pass the fuser transport sensor after its leading edge has reached the fuser transport sensor. |
Causes: | LGC board ADU board PFC board Rollers |
Remedy: | Is the fuser transport sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[7]/[C]) ↓ → NO → 1. Check if the connector of the fuser transport sensor is disconnected. 2. Check if the connector CN332 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the fuser transport sensor. 6. Replace the LGC board. YES Is the reverse motor driving? (Perform the output check in the test mode: 03-126) ↓ → NO → 1. Check if the connector of the reverse transport unit is not disconnected. 2. Check if the connector CN335 on the LGC board is not disconnected. 3. Check if the connector pins are not disconnected and the harness is not open circuited. 4. Check if the conductor pattern on the LGC board is not short- or open-circuited. 5. Replace the LGC board YES 1. Check if the separation finger for the fuser unit is working normally. 2. Replace the LGC board |
Error code: | E030 |
Description: | Power-ON jam: Paper is remaining on the paper transport path of the equipment when the power is turned ON. |
Causes: | Fuser transport sensor LGC board ADU board PFC board Rollers |
Remedy: | Open the cover of the unit/area whose picture is blinking on the control panel. Is there any paper on the transport path? (Refer to the following table.) → YES → Remove the paper. NO Is the sensor in the jamming area working? (Perform the input check in the test mode: refer to the following table.) ↓ → NO → 1. Check if the connector of the sensor is disconnected. 2. Check if any of the connectors on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the sensor. 6. Replace the LGC board. YES Replace the LGC board. Registration area Registration sensor 03-[FAX]ON/[4]/[E] Exit/Reverse area Exit sensor 03-[FAX]OFF/[7]/[B] Reverse sensor-1 03-[FAX]OFF/[7]/[E] Reverse sensor-2 03-[FAX]OFF/[7]/[D] Fuser transport sensor 03-[FAX]OFF/[7]/[C] Reverse transport area Horizontal transport sensor-1 03-[FAX]OFF/[9]/[F] Horizontal transport sensor-2 03-[FAX]OFF/[9]/[G] Horizontal transport sensor-3 03-[FAX]OFF/[9]/[H] Paper feeding area 1st drawer feed sensor 03-[FAX]OFF/[1]/[D] 2nd drawer feed sensor 03-[FAX]OFF/[2]/[D] 3rd drawer / tandem LCF feed sensor 03-[FAX]OFF/[3]/[D] 4th drawer feed sensor 03-[FAX]OFF/[4]/[D] 1st drawer transport sensor 03-[FAX]OFF/[1]/[C] 2nd drawer transport sensor 03-[FAX]OFF/[2]/[C] 3rd drawer / tandem LCF transport sensor 03-[FAX]OFF/[3]/[C] 4th drawer transport sensor 03-[FAX]OFF/[4]/[C] Intermediate transport sensor 03-[FAX]OFF/[1]/[A] |
Error code: | E061 |
Description: | Incorrect paper size setting for 1st drawer: The size of paper in the 1st drawer differs from size setting of the equipment. |
Remedy: | If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer. * Paper size detection is performed at the first sheet of paper when the drawer is opened or closed, or when the power of the equipment is turned ON. |
Error code: | E062 |
Description: | Incorrect paper size setting for 2nd drawer: The size of paper in the 2nd drawer differs from size setting of the equipment. |
Remedy: | If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer. * Paper size detection is performed at the first sheet of paper when the drawer is opened or closed, or when the power of the equipment is turned ON. |
Error code: | E065 |
Display: | E065 error X motor |
Description: | Incorrect paper size setting for bypass tray: The size of paper in the bypass tray differs from size setting of the equipment. |
Remedy: | If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer. * Paper size detection is performed at the first sheet of paper when the drawer is opened or closed, or when the power of the equipment is turned ON. |
Error code: | E090 |
Description: | Image data delay jam: Image data to be printed cannot be prepared. |
Causes: | SYS board IMG board LGC board HDD Page memory |
Remedy: | 1. Remove the paper remained in front of the registration sensor. 2. If the error still occurs, check the following: 3. Check if the error is cleared by turning the power OFF and then back ON. 4. Check if the connectors connecting the SYS board, SLG board and PLG board are disconnected. 5. Check if the connectors of the HDD are disconnected. 6. Check if the page memory is connected to the connector on the SYS board properly. 7. Replace the page memory. 8. Check if the harnesses connecting the SYS board, SLG board and PLG board are opencircuited. 9. Replace the HDD, SYS board, SLG board and PLG board. |
Error code: | E110 |
Description: | Transport jam during duplex printing (paper not reaching registration sensor): Paper which passed the reverse transport section does not reach the registration sensor during duplex printing. |
Causes: | Registration sensor ADU motor2 ADU board PFC board LGC board ADU roller |
Remedy: | (First page of printing) Open the jam access cover. Is there paper in front of the registration sensor? → YES → Remove the paper. NO Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[4]/[E]) ↓ → NO → 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN341 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES Is the transport motor (M17) rotating? (Perform the output check in the test mode: 03-133,183) ↓ → NO → Replace the transport motor. 1. Check if the connector of the transport motor is disconnected. 2. Check if the connector CN327 on the LGC board is disconnected. 3. Check if the connector on the transport motor driving PC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 6. Check if the conductor pattern on the transport motor driving PC board is short circuited or open circuited. 7. Replace the LGC board. 8. Replace the transport motor driving PC board. YES Check if the spring of the follower roller of the intermediate transport roller is working properly. YES Check the transport roller. Clean or replace it. (Second page or later of printing) Leading edge of paper not reaching the fuser exit sensor. ↓ → YES → If the paper is damaged, remove the paper and check the followings. 1. Check if the paper is skewed, and correct it if it is skewed. 2. Check the paper amount. 3. Check if the paper is not the one with printing on its back side. 4. Check if the width of the side guides of the drawer is too narrow. 5. Check the motor-related adjustment value. NO Is the intermediate transport sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[A]) ll → NO → 1. Are paper dusts accumulated on the intermediate transport sensor? 2. Check if the harness is not damaged. 3. Check if the connector is disconnected. YES Is the transport motor rotating? (Perform the output check in the test mode: 03-133,183) NO → Replace the transport motor. 1. Check if the connector of the transport motor is disconnected. 2. Check if the connector on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the LGC board. YES Check if the spring of the follower roller of the intermediate transport roller is working properly. Replace the registration roller(rubber) if not solved. |
Error code: | E120 |
Description: | Bypass misfeeding (paper not reaching registration sensor): Paper fed out of the bypass tray does not reach the registration sensor. |
Causes: | Bypass feed sensor Bypass motor Bypass pick-up solenoid ADU board PFC board ADU roller Rollers |
Remedy: | Open the bypass unit cover. Is there any paper in front of the registration sensor? → YES → Remove the paper. NO Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[4]/[E]) ↓ → NO → 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN341 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES Is the width of the side guides of the bypass unit too narrow? Is the paper skewed? → YES → Match the width of the side guides and that of the paper. NO Is the bypass feed clutch working? (Perform the output check in the test mode: 03-204) Is the bypass feed sensor working? (Perform the input check in the test mode: 03- [FAX]OFF/[6]/[G]) ↓ → NO → 1. Check if the connector of the bypass feed clutch and bypass feed sensor are disconnected. 2. Check if the connector CN327 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the bypass feed clutch and bypass feel sensor. 6. Replace the LGC board. YES Check the bypass transport roller, feed separation and separation rollers. Clean or replace them. |
Error code: | E130 |
Description: | 1st drawer misfeeding (paper not reaching 1st drawer feed sensor): Paper does not reach the 1st drawer feed sensor during the feeding at the 1st drawer. |
Causes: | 1st drawer feed sensor Feed motor PFC roller Rollers |
Remedy: | Open the feed cover. Is there any paper in front of the 1st drawer transport sensor? → YES → Remove the paper. NO Is the 1st drawer feed sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[D]) ↓ → NO → 1. Check if the connector of the 1st drawer feed sensor is disconnected. 2. Check if the connector CN329 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the 1st drawer feed sensor. 6. Replace the LGC board. YES Is the width of the side guides of the 1st drawer too narrow? Is there any paper skewing? → YES → Fit the width of the original guide to that of the paper. NO Is the 1st drawer feed clutch working? (Perform the output check in the test mode: 03-201) ↓ → NO → 1. Check if the connector of the 1st drawer feed clutch is disconnected. 2. Check if the connector CN329 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the 1st drawer feed clutch. 6. Replace the LGC board. YES Check the 1st drawer feed roller, separation roller and pickup roller. Clean or replace them. * Check if the paper weight is within the specified range. |
Error code: | E140 |
Description: | 2nd drawer misfeeding (paper not reaching 2nd drawer feed sensor): Paper does not reach the 2nd drawer feed sensor during the feeding at the 2nd drawer. |
Causes: | 2nd drawer feed sensor Feed motor PFC roller Rollers |
Remedy: | Open the drawer feed cover. Is there any paper in front of the 2nd drawer transport sensor? → YES → Remove the paper. NO Is the 2nd drawer transport sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[2]/[D]) ↓ → NO → 1. Check if the connector of the 2nd drawer feed sensor is disconnected. 2. Check if the connector CN329 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the 2nd drawer feed sensor. 6. Replace the LGC board. YES Is the width of the side guides of the 2nd drawer too narrow? Is there any paper skewing? → YES → Fit the width of the original guide to that of the paper. NO Is the 2nd drawer feed clutch working? (Perform the output check in the test mode: 03-202) ↓ → NO → 1. Check if the connector of the 2nd drawer feed clutch is disconnected. 2. Check if the connector CN329 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the 2nd drawer feed clutch. 6. Replace the LGC board. YES Check the 2nd drawer feed roller, separation roller and pickup roller. Clean or replace them. * Check if the paper weight is within the specified range. |
Error code: | E210 |
Description: | 2nd drawer transport jam (paper not reaching registration sensor): Paper which has passed the 1st drawer transport sensor does not reach the registration sensor during the feeding at the 2nd drawer. |
Causes: | Registration sensor Transport motor-1 PFC board LGC board Rollers |
Remedy: | (First page of printing) Open the jam access cover. Is there paper in front of the registration sensor? → YES → Replace the paper. NO Is the registration sensor(S18) working? (Perform the input check in the test mode: 03-[FAX]ON/[4]/[E]) ↓ → NO → 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN305 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES 1. Check the transport roller. Replace it if it is worn out. (Second page or later of printing) Open the jam access cover. Is there any paper on the transport path? ↓ → YES → If the paper is damaged, remove the paper and check the followings 1. Check if the paper is skewed, and correct it if it is skewed. 2. Check the paper amount. 3. Check if the paper is not the one with printing on its back side. 4. Check if the width of the side guides of the drawer is too narrow. 5. Check the motor-related adjustment value. NO Is the intermediate transport sensor (S17) working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[A]) ↓ → NO → 1. Are paper dusts accumulated on the intermediate transport sensor? 2. Check if the harness is not damaged. 3. Check if the connector is disconnected. YES Is the transport motor (M17) rotating? (Perform the output check in the test mode: 03-133,183) ↓ → NO → Check if the bearing of the transportation roller is locked. Replace the transport motor. 1. Check if the connector of the transport motor is disconnected. 2. Check if the connector CN327 on the LGC board is disconnected. 3. Check if the connector on the transport motor driving PC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 6. Replace the LGC board. 7. Replace the transport motor driving PC board. YES Check if the spring of the follower roller of the intermediate transport roller is working properly. Check if the registration roller (rubber) is rotating smoothly. |
Error code: | E400 |
Display: | Print Unable E4 Turn the power off and then back on again. |
Description: | Duplexing unit open jam |
Causes: | Fuse LGC board Switching regulator Interlock switch |
Remedy: | 1. Close the duplexing unit if it is opened. Remove if there is any paper before closing it. 2. Is the voltage of 24V being supplied from the power supply unit? (Perform the input check: 03- [COPY] ON/[6]/[A]) 3. Check if the connector CN309 on the LGC board is disconnected from the connector CN403 on the switching regulator or the harnesses are open circuited. Correct if any. 4. Check if the fuse (F201, F202, F203, and F204) on the switching regulator has blown. 5. Replace the PFC board. 6. Replace the switching regulator. 7. Is the interlock switch working properly? (Perform the input check: 03-[SCAN] ON/[4]/[G]) 8. Check if the connector CN312 on the LGC board is disconnected from the interlock switch or the harnesses are open circuited. Correct if any. |
Error code: | E410 |
Description: | Front cover open jam: The front cover has opened during printing. |
Causes: | Front cover opening/closing switch LGC board |
Remedy: | Is the front cover open? → YES → Remove the paper if there is any, then close the cover. NO Is the voltage of 24V being supplied from the power supply unit? (Perform the input check in the test mode: 03-[FAX] ON/[9]/[H]) ↓ → NO → 1. Check if the connector for 24 V power supply is disconnected. 2. Check if the connector CN344 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the LGC board. YES Replace the LGC board. |
Error code: | E430 |
Description: | ADU open jam: The ADU has opened during printing. |
Causes: | ADU opening/closing switch ADU board LGC board |
Remedy: | 1. Close the ADU if it is opened. Remove if there is any paper before closing it. 2. Is the ADU opening/closing switch working? (Perform the input check: 03-[FAX]ON/[2]/[C]) 3. Check if the connector CN338 on the LGC board is disconnected from the ADU opening/closing switch or the harnesses are open circuited. Check if the connectors CN211 and CN217 on the ADU board are disconnected. Correct if any. 4. Replace the ADU opening/closing switch. 5. Replace the ADU board. 6. Replace the PFC board. 7. Replace the LGC board. |
Error code: | E440 |
Description: | Right lower cover (feed cover) open jam: The feed cover has opened during printing. |
Causes: | ADU opening/closing switch LGC board |
Remedy: | Is the feed cover open? → YES → Remove the paper if there is any, then close the cover. NO Is the side door switch working? (Perform the input check in the test mode: 03-[FAX]ON/[2]/[A]) ↓ → NO → 1. Check if the connector of the feed cover sensor is disconnected. 2. Check if the connector CN304 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the feed cover sensor. 6. Replace the LGC board. YES Replace the LGC board. |
Error code: | E510 |
Description: | Transport jam during duplex printing (paper not reaching reverse sensor-2): Paper which has passed the reverse sensor-1 does not reach the reverse sensor-2 during duplex printing. |
Causes: | Duplexing unit path entrance sensor Reverse motor ADU motor-2 PFC board ADU board DRV board Rollers |
Remedy: | Open the exit cover. Is there any paper in front of the reverse sensor-2? → YES → Remove the paper. NO Is the reverse sensor-1 working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[G]) ↓ → NO → 1. Check if the connector of the reverse sensor-1 is disconnected. 2. Check if the connector CN335 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on LGC board are short circuited or open circuited. 5. Replace the reverse sensor-1. 6. Replace the LGC board. YES Is the horizontal transport section driving clutch working? (Perform the output check in the test mode: 03-222) ↓ → NO → 1. Check if the connector of the horizontal transport section driving clutch is disconnected. 2. Check if the connector CN334 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the horizontal transport section driving clutch. 6. Replace the LGC board. YES Is the Mylar at the reverse section normal? → NO → Replace the Mylar. YES Check the condition of the roller at the horizontal transport section and clean or replace it. |
Error code: | E550 |
Description: | Paper remaining jam at paper transport path: Paper is remaining on the paper transport path when the printing has finished. (Jam caused by a multiple paper feeding) |
Causes: | Feed or transport roller possibly causing multiple feeding Sensor in the jamming area Refer to the table below PFC board |
Remedy: | Open the cover of the unit/area whose picture is blinking on the control panel. Is there any paper on the transport path? → YES → Remove the paper. NO Is the sensor in the jamming area working? (Perform the input check in the test mode: refer to the following table) ↓ → NO→ 1. Check if the connector of the sensor is disconnected. 2. Check if any of the connectors on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the sensor. 6. Replace the LGC board. YES 1. Check if any multiple paper is fed from the drawer. 2. Replace the LGC board. Registration area Registration sensor 03-[FAX]ON/[4]/[E] Exit/Reverse area Exit sensor 03-[FAX]OFF/[7]/[B] Reverse sensor-1 03-[FAX]OFF/[7]/[E] Reverse sensor-2 03-[FAX]OFF/[7]/[D] Fuser transport sensor 03-[FAX]OFF/[7]/[C] Reverse transport area Horizontal transport sensor-1 03-[FAX]OFF/[9]/[F] Horizontal transport sensor-2 03-[FAX]OFF/[9]/[G] Horizontal transport sensor-3 03-[FAX]OFF/[9]/[H] Paper feeding area 1st drawer feed sensor 03-[FAX]OFF/[1]/[D] 2nd drawer feed sensor 03-[FAX]OFF/[2]/[D] 3rd drawer / tandem LCF feed sensor 03-[FAX]OFF/[3]/[D] 4th drawer feed sensor 03-[FAX]OFF/[4]/[D] 1st drawer transport sensor 03-[FAX]OFF/[1]/[C] 2nd drawer transport sensor 03-[FAX]OFF/[2]/[C] 3rd drawer / tandem LCF transport sensor 03-[FAX]OFF/[3]/[C] 4th drawer transport sensor 03-[FAX]OFF/[4]/[C] Intermediate transport sensor 03-[FAX]OFF/[1]/[A] |
Error code: | E552 |
Description: | Paper remaining jam on the transport path (when the cover is closed) |
Causes: | Feed or transport roller possibly causing multiple feeding Sensor in the jamming area Refer to the table below. LGC board |
Remedy: | 1 Jamming transport path Open the cover of the unit/area whose picture is flashing on the control panel and remove any paper on the transport path. 2 Sensor in the jamming area • Sensor check (Refer to the table below) • Harness check • Connector check 3 LGC board • Harness check • Connector check • Board check Notes: If the jam is occurring in the ADU, LCF or PFP, check the board in each unit. Registration area Jam access cover Registration sensor 03-[ALL]OFF/[9]/[A] Paper clinging detection sensor 03-[ALL]OFF/[9]/[E] Registration pass sensor 03-[ALL]OFF/[9]/[F] Feed sensor 03-[ALL]OFF/[9]/[B] Exit area Fuser cover Exit sensor 03-[ALL]OFF/[9]/[C] ADU ADU ADU entrance sensor 03-[ALL]OFF/[9]/[G] ADU exit sensor 03-[ALL]OFF/[9]/[H] Bypass feed unit Side cover 2nd drawer feed sensor 03-[FAX]ON/[4]/[D] LCF LCF side cover LCF feed sensor 03-[COPY]ON/[9]/[F] PFP PFP side cover PFP upper drawer feed sensor 03-[FAX]ON/[0]/[C] PFP lower drawer feed sensor 03-[FAX]ON/[0]/[D] Bridge unit Bridge unit Bridge unit transport sensor-1 (Entrance sensor) 03-[ALL]OFF/[0]/[A] Bridge unit transport sensor-2 (Exit sensor) 03-[ALL]OFF/[0]/[B] Finisher Finisher door Sensors in the finisher |
Error code: | E714 |
Description: | Feed signal reception jam: The feed signal is received even no original exists on the original feeding tray. |
Causes: | Original empty sensor RADF board Perform the 05-3210 Roller Pickup roller, feed roller, separation roller |
Remedy: | 1. Is the original empty sensor working? (Perform the input check: 03-[FAX]ON/[7]/[B]) 2. Check if the lever of original empty sensor is working normally. 3. Check if the connector CN74 on the RADF board is disconnected from the original empty sensor or the harnesses are open circuited. Correct if any. 4. Replace the original empty sensor. 5. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356). |
Error code: | E721 |
Description: | Jam not reaching the original reading start sensor: The original does not reach the original reading start sensor after it has passed the original registration sensor (when scanning obverse side) or the reverse sensor (when scanning reverse side). |
Causes: | Original reading start sensor RADF board Perform the 05-3210 Roller Registration roller, Read roller |
Remedy: | 1. Clean the original registration roller, intermediate transfer roller, reading start roller, reverse roller and reverse registration roller if they are stained. 2. Is the original reading start sensor working? (Perform the input check: 03-[FAX]ON/[7]/[G]) * If it is working properly, proceed to 8. If not, check 3 to 7 below. 3. Check if the connector CN75 on the RADF board is disconnected from the original reading start sensor or the harnesses are open circuited. Correct if any. 4. Perform the automatic adjustment of the original reading start sensor (05-356). 5. Perform the manual adjustment of the original reading start sensor. 6. Replace the original reading sensor, and then perform the automatic adjustment of the original reading start sensor (05-356). 7. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356). 8. Replace the original registration roller, intermediate transfer roller, reading start roller, reverse roller and reverse registration roller if they are worn out. |
Error code: | E725 |
Description: | Stop jam at the reading start sensor: The trailing edge of the original does not pass the read sensor after its leading edge has reached this sensor. |
Causes: | Original reading start sensor RADF board Perform the 05-3210 Roller Registration roller, Read roller |
Remedy: | 1. Clean the original registration roller, intermediate transfer roller, reading start roller, reverse roller and reverse registration roller if they are stained. 2. Is the original reading start sensor working? (Perform the input check: 03-[FAX]ON/[7]/[G]) * If it is working properly, proceed to 8. If not, check 3 to 7 below. 3. Check if the connector CN75 on the RADF board is disconnected from the original reading start sensor or the harnesses are open circuited. Correct if any. 4. Perform the automatic adjustment of the original reading start sensor (05-356). 5. Perform the manual adjustment of the original reading start sensor. 6. Replace the original reading sensor, and then perform the automatic adjustment of the original reading start sensor (05-356). 7. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356). 8. Replace the original registration roller, intermediate transfer roller, reading start roller, reverse roller and reverse registration roller if they are worn out. |
Error code: | E726 |
Description: | Transport/exit signal reception jam during ADF standby status |
Remedy: | 1. Check if there is any paper in the RADF. Remove it if there is. 2. Check if there is any paper in the equipment. Remove it if there is. 3. If a jam still occurs, turn the power OFF and then back ON to check if the equipment operates normally. |
Error code: | EAD0 |
Description: | Print end command time-out jam: The printing has not finished normally due to the communication error between the SYS board and LGC board at the end of the printing. |
Causes: | SYS board LGC board |
Remedy: | Is the main motor rotating normally? → NO 1. Check if there is any paper in the equipment. Remove it if there is. 2. If the error still occurs, check the following: 3. Check if the error is cleared by turning the power OFF and then back ON. 4. Check if the connectors connecting the SYS board, SYSIF board, SLG board and PLG board are disconnected. 5. Check if the harnesses connecting the SYS board, SLG board and PLG board are open circuited. 6. Replace the SYS board, SYSIF board and LGC board. |
Error code: | EB50 |
Description: | Paper remaining on the transport path: The multiple feeding of the preceding paper caused the misfeeding of the upcoming paper. |
Causes: | 1st drawer feed sensor Bypass feed sensor ADU exit sensor Registration sensor 1st drawer feed sensor 2nd drawer feed sensor ADU board LGC board Rollers |
Remedy: | In case the paper is fed from the 1st drawer, bypass unit or Open the bypass unit cover. Is there any paper in front of the drawer feed sensor? ll → YES → Remove the paper. * Clean or replace the feed roller and separation roller if this error occurs frequently. NO Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[4]/[E]) ↓ → NO → 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN341 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES Check the rollers. Clean or replace them. In case the paper is fed from the 2nd drawer, 3rd drawer, 4th drawer, Tandem LCF Open the bypass unit cover. Is there any paper in front of the 1st drawer transport sensor? ll → YES → Remove the paper. * Clean or replace the feed roller and separation roller if this error occurs frequently. NO Are the 1st drawer transport sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[C]) ↓ → NO → 1. Check if the connector of the 1st drawer transport sensor is disconnected. 2. Check if the connector CN329 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the 1st drawer transport sensor. 6. Replace the LGC board. YES If any paper remains in the equipment or drawer, remove it. Check the rollers. Clean or replace them. |
Error code: | EB60 |
Description: | Paper remaining on the transport path: The multiple feeding of the preceding paper caused the misfeeding of the upcoming paper (= redetection after no jam is detected at [EB50]). |
Causes: | Registration sensor PFC board Rollers |
Remedy: | Open the bypass unit cover. Is there any paper in front of the registration sensor? → YES → Remove the paper. NO Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[4]/[E]) ↓ → NO → 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN341 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES Check the rollers. Clean or replace them. |
Error code: | F070 |
Description: | Communication error between System-CPU and Engine-CPU |
Causes: | Switching regulator • Replace the fuse (F210). • Replace the switching regulator. LGC board SYS board If the problem is not corrected with the replacement of the LGC board, reinstall the removed LGC board and replace the SYS board. IMG board If the problem is still not corrected with the replacement of the SYS board, reinstall the removed SYS board and replace the IMG board. |
Remedy: | (1) Check if the connector CN104 on the SYS board and CN130, CN131, CN134 on the SYSIF board is disconnected. (2) Check if the connector CN10 on the SLG board is disconnected. (3) Check if the harness connecting the SYSIF board and SLG board is disconnected or open circuited. (4) Check if the harness connecting the SYSIF board and LGC board is disconnected or open circuited. (5) Check if the connection of the SYS board (CN104) and SYSIF board (CN130) is open circuited. (6) If the SYS board has been replaced, check if the jumper pin setting on the SYS board is correct. (The jumper pin should be inserted between pin 2 and 3 of CN103 and CN115.) (7) Check the version of the system ROM on the SYS board. (8) Check the version of the engine ROM version on the LGC board. (9) Check the version of the scanner ROM version on the SLG board. (10) Replace the SYS board. (11) Replace the SLG board. (12) Replace the LGC board. (13) Replace the SYSIF board. |
Error code: | F090 |
Description: | SRAM abnormality on SYS board |
Causes: | SRAM (SYS board) |
Remedy: | (1) Turn the power OFF and start up the Setting Mode (08). (2) When “SRAM ERROR DOES IT INITIALIZE” is displayed on the LCD, check the destination and then press the [START] button. If the destination is not correct, key in the correct one and then press the [START] button. (3) After the confirmation message is displayed on the LCD, press the [INTERRUPT] button (to initialize the SRAM). (4) Perform the panel calibration (08-692). (5) Perform the initialization at the software version upgrade (08-947). (6) Enter the serial number (08-995). Be sure that the serial number is the same as that on the identification label attached on the rear cover of the equipment. Note: The MAC address of the equipment is generated based on this serial number. Entering the incorrect serial number may result in an inability to access the network due to an invalid MAC address. (7) Initialize the NIC information (08-693). (8) Turn the power OFF and then start up with the Adjustment mode (05). (9) Turn the power OFF and then back ON. If the error is not recovered, replace the SRAM on the SYS board. |
Error code: | F901 |
Description: | Engine speed error: The speed information of the LGC board is damaged. |
Causes: | Harness LGC board |
Remedy: | LGC board Check if the LGC board in which is corresponded to the equipment model is installed. Check if the label color of the LGC board (indicated in the figure with the arrow) is corresponded to the equipment model (indicated on the rating label). e-STUDIO206L: White e-STUDIO256: Pink e-STUDIO306: Blue e-STUDIO356: Yellow e-STUDIO456: Green e-STUDIO506: Red • Position of the label to be checked If they are not corresponding correctly, replace the LGC board with the correct one by referring to the procedures described below. Reference: "9.2.5Procedures when replacing the LGC board" Notes: The F901_1 may occur especially when the equipment is not started up with the 08 mode according to the procedures when replacing the LGC board. |